Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 27

 Well is shut in and pressures allowed to stabilize.

 Shut-in Drillpipe pressure + Hydrostatic = Bottom Hole Pressure.


 Kill the well using the Drillers Method.

300
500

CLOSE OPEN

DP CP
300 500

Mud weight = 10ppg

10,000 X 10 X .052 = 5,200 psi


BHP
5,200 + 300 = 5,500 psi
TVD = 10,000 ft.
1
Casing Pressure is held constant as pumps are brought up to
speed by opening the choke.
If the Casing Pressure is held constant when starting then BHP is
held constant.
Once pumps are up to speed the Drillpipe Pressure should be held
constant to keep BHP constant.
1300
500

CLOSE OPEN

DP CP
1300 500
KRP @40 spm = 1,000psi
ICP = 1000 + 300 = 1,300 psi on DP

BHP
5,500
2
 Till the gas influx gets farther up the hole there is little expansion and
the Casing pressure will rise slowly as mud (hydrostatic) is pushed out
of the hole.

1300
520

CLOSE OPEN

DP CP
1300 520

BHP
5,500
3
 As the bubble begins to expand it pushes mud out of the hole causing a
loss of hydrostatic.
 To keep BHP contsant, Drillpipe pressure must be kept constant.

1300
650

CLOSE OPEN

DP CP
1300 650

BHP
5,500
4
1300
800

CLOSE OPEN

DP CP
1300 800

BHP
5,500
5
1300
1000

CLOSE OPEN

DP CP
1300 1000

BHP
5,500
6
1300
1100

CLOSE OPEN

DP CP
1300 1100

BHP
5,500
7
1300
1250

CLOSE OPEN

DP CP
1300 1250

BHP
5,500
8
1300
1400

CLOSE OPEN

DP CP
1300 1400

BHP
5,500
9
1300
1600

CLOSE OPEN

DP CP
1300 1600

BHP
5,500
10
1300
1750

CLOSE OPEN

DP CP
1300 1750

BHP
5,500
11
1300
1000

CLOSE OPEN

DP CP
1300 1000

BHP
5,500
12
1300
400

CLOSE OPEN

DP CP
1300 400

BHP
5,500
13
 Once the influx is circulated out, the well should be shut-in.
 Compare the Drillpipe and Casing pressure gauges and confirm
that they are equal. If Casing pressure is greater than Drillpipe
pressure then you may not have all the influx out of the well.
Once you are confident that the annulus is clean line up the pumps
on Kill Weight Fluid.
300
300

CLOSE OPEN

DP CP
300 300

BHP
5,500
14
 Hold Casing pressure constant as you bring the pumps up to 40 spm.

 Continue to hold Casing pressure constant as you displace the drillstring.

 Drillpipe pressure should drop as hydrostatic in the drillpipe increases.

1300
300

CLOSE OPEN

KRP @40 spm = 1,000psi DP CP


ICP = 1000 + 300 = 1,300 psi on DP 1300 300

BHP
5,500
15
1250
300

CLOSE OPEN

DP CP
1250 300

BHP
5,500
16
1200
300

CLOSE OPEN

DP CP
1200 300

BHP
5,500
17
1150
300

CLOSE OPEN

DP CP
1150 300

BHP
5,500
18
1100
300

CLOSE OPEN

DP CP
1100 300

BHP
5,500
19
 Once the Drillpipe is full of Kill Weight Fluid the hydrostatic will
remain constant.
Continue circulating holding Drillpipe pressure constant at FCP.
 Casing pressure should drop as Kill Weight Fluid displaces the
annulus.
1060
300

CLOSE OPEN

DP CP
1060 300

BHP
5,500
20
1060
300

CLOSE OPEN

DP CP
1060 300

BHP
5,500
21
1060
250

CLOSE OPEN

DP CP
1060 250

BHP
5,500
22
1060
200

CLOSE OPEN

DP CP
1060 200

BHP
5,500
23
1060
150

CLOSE OPEN

DP CP
1060 150

BHP
5,500
24
1060
100

CLOSE OPEN

DP CP
1060 100

BHP
5,500
25
1060
50

CLOSE OPEN

DP CP
1060 50

BHP
5,500
26
 After confirming that Kill Weight Fluid is back to surface, shut the well in.
 Drillpipe and Casing pressure should read 0 psi.
Open the choke and check for flow. When opening the Annular beware of
gas trapped under the element.

0
0

CLOSE OPEN

DP CP
0 0

BHP
5,500
27

You might also like