Protection (Transformer)
Protection (Transformer)
M L SHESHADRI 04/29/20
PROTECTION OF2 TRANSFORMER
• INTRODUCTION
• Power transformer is a vital link in power system.
Therefore we have to have a reliable, secured and
fast acting protection system for the transformer.
This will minimize the damage to the transformer in
case of internal fault. The protection system should
also have a proper backup protection scheme to take
care of un-cleared system fault.
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
3
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
4
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
5
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
Source of abnormal stress 6 in a transformer
The source of abnormal stress in transformers is
Overload
System faults
Over voltage / reduced system frequency
Overload:
It causes increase in copper loss, which results in increase
of winding temperature. If the transformer is overloaded
continuously, the oil gets deteriorated resulting in
reduced insulation and other consequence thereafter. It is
the temperature rise that decides how long we can
overload the transformer and there should be proper
cooling of transformer oil.
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
7
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
• PROTECTION TOOLS FOR TRANSFORMERS
8
• To protect the transformers from the above-mentioned
faults, following protection and safety devices are used.
• The degree of protection schemes depends on
application, voltage and MVA ratings.
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
9
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
10
M L SHESHADRI 04/29/20
PROTECTION OF11 TRANSFORMER
• PROTECTION TOOLS FOR TRANSFORMERS
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
12
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMERS
13
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMERS
14
Difficulties in Differential protection
CT ratio errors during short circuits occur during
short circuits due to inherent CT characteristics
differences arising out of magnetic circuits,
saturation conditions and unequal dc components
in the short circuit currents. This may result in
operation of relay even for external faults.
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMERS
Magnetising inrush current
15
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMERS
16
M L SHESHADRI 04/29/20
TRANSFORMER PROTECTION
M L SHESHADRI 17 04/29/20
PROTECTION OF TRANSFORMER
18
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
19
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
20
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
21
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
22
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
23
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
24
• PROTECTION TOOLS FOR TRANSFORMERS
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMERS
BUCKHOLTZ RELAY
25
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
26
M L SHESHADRI 04/29/20
PROTECTION OF27TRANSFORMERS
TEMPERATURE
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMERS
28
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
29
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMERS
30
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMERS
PRESSURE RELIEF VALVE
31
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
32
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMERS
MAGNETIC OIL LEVEL GAUGE
33
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
34
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMERS
BREATHER
35
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMERS
THERMO SYPHON FILTER
36
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
37
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMERS
AIR CELL
38
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMERS- DIELECTRIC
DISSIPATION FACTOR
39
M L SHESHADRI 04/29/20
PROTECTION OF TRANSFORMER
40