Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 53

Training Manual

MODERATO-P/J
-. AQ09MSB
-. AQ12MSB
-. AQ18MSB
-. AQ24MSB

System Appliances Division


CONTENTS

1. FEATURE
2. Structure
3. Connecting Diagram
4. Control System
5. Diagram Schematic
6. Error Mode
7. Troubleshooting
8. Working Principle
9. Experimental
Data
10. Disassembly and Assembly
11. Refrigerating Cycle Diagram
Feature – 1. Development
Background
1. ’06R HB-PJT
2. ’07R MODERATO-PJT

2006 2007

SGEC DROP
HB

New
Europe

Middle East
SSEC MODERATO
Africa

Asia
Feature – 2. Product Striking Concept
Feature – 3. Product Specification (1)

Specification
Feature – 3. Product Specification (2)

Specification
Feature – 5. Product Specification (3)
Feature – 5. Product Specification (4)
Feature – 5. Product Specification (5)
Feature – 5. Product Specification (6)
Feature – 6. Product Function (1)

Basic Function
Feature – 6. Product Function (2)
Feature – 6. Product Function (3)
Feature – 6. Product Function (4)
Feature – 6. Product Function (5)
Feature – 6. Product Function (6)
Feature – 6. Product Function (7)
Structure – The Development Figure (1)

Indoor
Unit
Structure – The Development Figure (2)
Structure – The Development Figure (3)
Outdoor Unit
(9, 12K)
Structure – The Development Figure (4)
Outdoor Unit
(18K)
Structure – The Development Figure (5)
Outdoor Unit
(24K)
Connecting Diagram

Indoor Main PCB


Connecting Diagram

Indoor Main PCB


Control System (1)

Automatic Operation
Control System (2)

Cooling Operation
Control System (3)

Heating Operation
Control System (4)
Turbo Operation
Diagram Schematic – 1. Indoor
Indoor Diagram
Diagram Schematic – 2. Outdoor

Outdoor Diagram
Diagram Schematic - 3. Circuit Diagram

Main Circuit Diagram


Diagram Schematic - 4. Circuit Explanation (1)

Indoor Fan Control


Diagram Schematic - 4. Circuit Explanation (2)

Indoor Stepping Motor Control


Error Mode
Error Mode (1)
Error Mode (2)
Error Mode (3)
Troubleshooting
Troubleshooting
Troubleshooting
Troubleshooting
Troubleshooting
Working Principle – 1. DISPLAY
Working Principle – 2. CROSS FAN DISASSEMBLING METHOD

The Indoor Cross Fan can be drown out by loosening 1 screw


Without disassembling other items (ex. Assy control in, Motor,
Holder Motor etc.).
Experimental Data – 1. CAPACITY

These graphs show the relation between Length of


Connecting Pipe and Capacity in cooling and heating mode.

Cooling Capacity Heating Capacity

6.6 6.9

6.5 6.8

Heating Capacity(kW)
Cooling Capacity(kW)

6.4 6.7

6.3 6.6
7.5 15 7.5 15
Length of Connecting Pipe(m) Length of Connecting Pipe(m)
Experimental Data – 2. Power Consumption

These graphs show the relation between Length of Connecting


Pipe and Power Consumption in cooling and heating mode.

Power Consumption(Cooling) Power Consumption(Heating)

2590 2680

2570 2660

2640
2550
Power Consumption(W)

Power Consumption(W)
2620
2530
2600
2510
2580

2490
2560

2470 2540
7.5 15 7.5 15
Length of Connecting Pipe(m) Length of Connecting P ipe(m)
Experimental Data – 3. Air Flow Rate (Air Volume)

These graphs show the relation between RPM and Air Flow Rate.

Air Volume according to the RPM variation (High/Mid/Low)

15
Air Flow Rate (m3/min)

14

13

12

11

10

9
High Mid Low
RPM

24000 BTU-Cooling 24000 BTU-Heating


Disassembly and Assembly – 1. Indoor (1)
Disassembly and Assembly – 1. Indoor (2)
Disassembly and Assembly – 1. Indoor (3)
Disassembly and Assembly – 2. Outdoor (1)
Disassembly and Assembly – 2. Outdoor (2)
Refrigerating Cycle Diagram

You might also like