Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 33

Internal

OptiX SDH/OSN Series


Equipment General
Configuration
www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved


References

 OptiX T2000 Operator Guide for SDH

 OptiX iManager T2000 Administrator


Guide for SDH
 OSN3500&2500&1500 Configuration
Guide
 OSN7500 Configuration Guide

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 2


 Upon completion of this course, you will be able to:

 Understand the menus of OptiX iManager T2000


 Create Topology including create NE/Link
 Perform the NE configuration, board configuration,
service dispatching and protection configuration for
equipment via OptiX iManager T2000

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 3


Chapter 1 Creating Topologies

Chapter 2 Configuring Protection

Chapter 3 Configuring Services

Chapter 4 Configuring Clock

Chapter 5 Configuring Overhead Interface

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 4


Chapter 6 Configuring Alarm and Performance
Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 5


Creating Topologies

 Recommended Creation Sequence

Step Description

1 Creating GNEs & NEs

2 Creating a Sub-racks and Boards

3 Creating Links

4 Creating a Topology Subnet

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 6


Creating Topologies

 Creating Optical NEs in batch


 Select [File/Search for NE] from the Main
Menu.
 Click <Start Search>. The NEs found are
displayed after the search.
 Click <Stop Search>, and click <Yes> in the
confirmation box.
 Click <Create NE>.
 Enter the NE user name and password.
 Click <OK>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 7


Creating Topologies
 Creating Optical NEs Manually
Creating Gateway Network Element (GNE)

1. Click File/Create/Topology Object.


2. Choose the NE type to be created.
3. Complete the following information: ID,
extended ID, name and remarks.
4. Select "Gateway" from the "Gateway Type"
drop-down list and "IP" from the "Protocol"
drop-down list. Enter the IP address and
port number of the GNE.
5. Enter the NE user and password.
6. Click <OK>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 8


Creating Topologies
 Creating Optical NEs Manually
Creating Non-Gateway Network Element

1. Click File/Create/Topology Object.


2. Choose the NE type to be created.
3. Complete the following information: ID,
extended ID, name and remarks.
4. Select "Non-Gateway" from the "Gateway
Type" drop-down list. Select the GNE the
NE is affiliated to from the "Affiliated
Gateway" drop-down list.
5. Enter the NE user and password.
6. Click <OK>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 9


Creating Topologies

 Creating Sub-racks and Boards (1/2)


 Double-click unconfigured NE icon on the Main Topology.
 Select "Manual Configuration" and click <Next>.
 Click <OK> in the two "Confirm" dialogue box.
 Set the NE attributes and click <Next>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 10


Creating Topologies

 Creating Sub-racks and Boards (2/2)


The NE Panel is displayed.

1. Right-click the slot and select the board type or Click


<Query Physical Slot (s)> to upload the data to the
physical slot from the NE.
2. After all the boards have been created, click <Next>.
3. Click <Finish>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 11


Creating Topologies
 Creating fibers manually
 Searching fibers 1. Select the shortcut icon on the
 Select [File/Search for Fiber/Cable]. toolbar of the Main Topology and
the cursor changes to a "+".
 Click <Search>.
2. Click the source NE of the fiber or
 After finding the fibers, Click <Close>.
cable on the Main Topology.
 Click <Create Fibre>.
3. Select the source board and port.
4. Click <OK> and the cursor
changes to a "+".
5. Click the sink NE of the fibre or
cable on the Main Topology.
6. Select the sink board and port
7. Click <OK> twice.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 12
Creating Topologies

 Creating a Topology Subnet

1. Select [File/Create/Subnet].
2. Select the "Basic Attributes" tab. Enter the
information of the subnet.
3. Select the "Object Selection" tab. Select
the created NEs or subnet from the "Object
Not Selected" pane, and add them to the
"Selected Object" pane by clicking the
double-right-arrow button.
4. Click <OK>.
5. Click in the Main Topology.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 13


Chapter 1 Creating Topologies

Chapter 2 Configuring Protection

Chapter 3 Configuring Services

Chapter 4 Configuring Clock

Chapter 5 Configuring Overhead Interface

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 14


Configuring Protection
Equipment level protection

Configuring TPS Protection Configuring Board-level Protection

Network level protection

Configuring MSP Ring Configuring SNCP

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 15


Configuring Protection
Equipment Level Protection
 Configuring TPS Protection
 In the NE Explorer, click the NE and select [Configuration/TPS
Protection] from the Function Tree.
 Click <Create> to enter the dialog box .
 Select a protection board and working boards. Set switching priorities
for the working boards.
 Set the "WTR Time“.
 Click <OK>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 16


Configuring Protection

 Creating Board-level Protection


 In the NE Explorer, click the NE and select [Configuration/Board-Level
Protection] from the Function Tree.
 Click <New>.
 Select Primary Board and Standby Board, and set Protection Group ID.
 Click <OK>.
 Click <Close>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 17


Configuring Protection
Network Level Protection

 Creating a Two-Fiber MS-SPRing


 Select [Configuration/Protection View]
 Select [Protection View/Create SDH Protection Subnet/2f_MS SPRing].
 Select the rate of the protection subnet.
 Double-click on the nodes to be in the protection subnet.
 Click <Next>.
 Click <Finish> to send the configurations.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 18


Configuring Protection
 Configuring SNCP Protection
 Select [Configuration/Protection View] from the Main Menu.
 Right-click the NE to be created as the SNCP node, and select
[Create SNCP Node/Create xxx SNCP Node] ("xxx" refers to the
name of the protection subnet of this NE)

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 19


Chapter 1 Creating Topologies

Chapter 2 Configuring Protection

Chapter 3 Configuring Services

Chapter 4 Configuring Clock

Chapter 5 Configuring Overhead Interface

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 20


Creating an NE User
1.Select [System Administration/NE Security Management/NE User Management]
from the menu
2.Select NE from the object tree. Select NE and click <Add>.
3.Enter the name, user level, user flag, password, and detailed description of the
new NE user: e.g. create a unified NE user “t2000” for NE1–NE5, as shown in the
diagram below. The length of the password of the NE user ranges from 6 to16
characters, including at least one letter and one numeral. And the length of the “NE
User” ranges from 2 to 8 characters

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 21


Chapter 6 Configuring Alarm and Performance
Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 22


Configuring communication
 Setting NE Communication
Parameters
 1. In the NE Explorer, click the
NE and select
[Communication/Set
Communication Parameters]
from the Function Tree
 2. Click <Refresh> to update
the communication
parameters
 3. Modify the IP, Extended ID,
Gateway IP, Subnet Mask or
NSAP Address as you need,
and click <Apply>.

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 23


Configuring communication
 Changing an Ordinary NE into a GNE
 1. Select [System Administration/DCN Management] from the Main Menu
 2. Select the “NE” tab.
 3. Right-click an ordinary NE and select [Change to GNE]. The “Change to
GNE” dialog box is displayed;
 4. Set the “GNE type”, “IP Address” and “Port No.” as you need

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 24


Configuring communication
 Adding Standby GNEs for an NE

 1. Select [System Administration/DCN Management] from the


Main Menu
 2. Select the “NE” tab

 3. Select an NE entry, add standby GNEs

 4. Click <Apply>

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 25


Chapter 6 Configuring Alarm and Performance
Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 26


Configuring Board Parameters

 Configuring SDH Boards

 Configuring PDH Boards

 Configuring Ethernet Boards

 Configuring Optical Amplifier Boards

 …………………….

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 27


Configuring the Optical Transponder Unit

1, In the NE Explorer, select an SDH board and select


[Configuration/SDH Interface] from the Function Tree ;
2, Click the double-right-arrow button (red). Select "By Function" ;

3, Select the parameter in the drop-down list ;

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 28


Chapter 6 Configuring Alarm and Performance
Monitoring
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 10 Configuring Board Parameters
Chapter 11 Reports

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 29


Reports
 The Network Diagram

 The Network wide Data Report

 The NE Information Report

 The Physical Location Information Report

 The Slot Configuration Report

 The Board Information Report

 The Slot Information Report

 The Board Details Report

 The Fiber/Cable Connection

 Report

 …………………..

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 30


Reports

The Network wide Data Report

1, Select [Report/Network wide


Data Report] from the Main Menu;
2, Click <Print> or <Save As>.

The Board Information Report

1. Select [Report/Board Information Report]


from the Main Menu ;
2. Select NEs from the left pane and click
the double-right-arrow button (red)
3. Select the "View Board Information" tab.
Click <Print> or <Save As>

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 31


 How to configure the SDH service?
Summary
answer
 How to configure the clock? answer

 How to backup the NE data


configuration? answer

HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 32


Thank You
www.huawei.com

You might also like