FC160

Hand-held Fundus Camera


Smart Retinal Imaging Solution
Index

 Product Features
 Target Markets
 Retina Images Display
 Product Advantages
 Operation Instruction
 Common Questions from Customer

The 3.97” touch screen


displays retinal images
clearly to facilitate
doctors’ pathology
analysis.
With touch screen,
doctors do not need to
press a lot of buttons to
check different images.
They just need to slide
photos like using a
mobile phone.
Product Features

Non-Mydratic Portable 3.97” Touch Screen

Using MediWorks’ The smart design The 3.97” touch screen


Fundus Camera FC enables doctors to displays retinal images
160 does not require carry it wherever clearly to facilitate
doctors to dilate needed. That makes doctors’ pathology
patients’ pupils which outdoor examination analysis.
will take 20 minutes much easier With touch screen,
before shooting retina compared with desk doctors do not need to
imaging. Doctors can top fundus camera. press a lot of buttons to
capture retinal image check different images.
directly once the They just need to slide
image is in focus. photos like using a
mobile phone.
Product Features

45°

In-device Patient
45° Visual Field
Case Management
The Miracast technology
The Miracast
enables doctors to show The 45°visual field Doctor can input patient
technology
retinal image enables
on the large enable doctors to info. and build up patient
doctors to show
screen synchronically check basic retina file in the device.
retinal image
with FC 160. Thison the
helps situation of the
large
doctorsscreen
to illustrate and patients.
educate pathologywith
synchronically with
FC 160. This helps
others.
doctors to illustrate
and educate
pathology with others.
Target Markets

District
First Class
Community Hospital/Endo
Hospital/
Health Care crinology
Endocrinology
Endocrinology
District
Hospital/ First Class
Community
Ophthalmology Ophthalmolo Hospital/
Health Care
gy Ophthalmology

District First Class


Community
Hospital Hospital

Good choice for retina screening!


Clinical Applications

Community Primary Eye


Clinic Regular Eye Check
Check

Ward Check Academic Education


Clinical Diagnosis

Diabetic Retinopathy
Screening Glaucoma Screening

AMD Screening High Myopia Screening


Captured Image Display

Observe Pathologies: microaneurysm,  intraretinal hemorrhage, hard exudates, cotton-wool spots,


 intraretinal microvascular abnormality, venous beading, new vessels, vitreous hemorrhage, preretinal
hemorrhage, fibroplasia
Market Positioning

Desk Top
Fundus Camera

Hand-held
High cost-
Fundus Camera
performance
effectiveness!
Retinoscope
Why Choose FC 160

The product and all accessories can be packed into a small


portable case enable doctors to carry it anywhere safely to
Mobile Carry do the examination at any place. The device can work 3
hours after fully recharged.
Why Choose FC 160

The doctor can use FC 160 at a comfortable distance without


getting too close to the patient. With the 3.97” screen, it’s easy for
Convenient the doctor to confirm the suitable image and thus click button to
Operation capture image.
Why Choose FC 160

With less money, doctors can get clinically acceptable images


Cost Effective to assist their diagnosis for the pathology.

佳能的 logo
去掉一下
FC160 Specification

Non-mydriatic Hand-held Fundus Camera


Capture Range
Retina Macular Optical Disc Vein and Artery of
Retina
Screen 3.97” Visual Field 45 degrees
Touch Screen
Resolution 5 Mega Pixels Illumination White LED
& Infrared LED
Data Format JPEG(Photograph Focus Range -20D to +20D
)
& 3GP(Video)
File Transfer Micro USB Memory Micro SD card.
& Wi-Fi Standard 16G
Maximum 32G
Battery Rechargeable Li- Working Time 3 hours
Ion 3.7 V
Weight 500g Dimention 28×13×15 cm
Product Details

Hand-held Eyepiece
fundus cover
camera

Power
adaptor
Carry
case
Recharging
Station
USB Cable
Operation Instruction

Touch
Screen Power
Indicator
Capture
Button
Recharging Device
Station

Switch
Scope
ring USB slot
SD card slot
Scope
Focusing Wheel

Rechargi
ng port
Operation Instruction
Install the protecting cover onto the front end of the scope.
Operation Instruction

Install battery into the back


side of the device.

Please use standard 18650 battery.


Spec: 3.7V, 3000mAh
Recommendation: Panasonic battery
3400mAh
Operation Instruction
Recharge Method:
1. Recharge with USB
cable
2. Recharge with charging
station.

Please recharge for 6


hours when first use the
device.
Power Status Indication

Power Off Recharging Working

No Light Orange Light Blue Light


Operation Instruction
Switch on device:
Press the button on the
left side to switch on the
device. Please wait 20
seconds to enter
capturing interface.
Long press the button to
switch off the device.
Operation Instruction
Exposure Indicator Timing

Power Indicator

Photo Mode

Video Mode Build up new


Patient File

ISO Gain Setting


Indicator

Fixation Light Photo Album

Left Eye Right Eye


Operation Instruction

Settings: It is suggested to use the default value.


Operation Instruction

ISO Gain Adjustment Values range from 1B~10B. The larger value indicates
higher brightness. It is suggested to set at 5B~6B.

Figure Description Operation


Fig.1 Preview image too dark Increase ISO value
Fig.2 Preview image OK Keep current ISO
Fig.3 Preview image too bright Lower ISO value

Fig.1 Fig.2 Fig.3


Operation Instruction

Build up new patient file

After inputting patient info., you will be able to build up a new folder for the patient.
All the photos and video shoot for this patient will be saved in this particular folder
naming with patient’s name and ID. Every time you build up a new file, there will be a
new separate folder for the patient.

Note: If the patient name and ID already exists in the device, the device will not make
a new file but open the existed file.
Operation Instruction
1.Use one hand to hold the device
handle with thumb putting on the
capture button and index finger
positioning on the focusing wheel.
Operation Instruction

2. Focus on a near object before


checking patient’s eye. Adjust the
focusing wheel to make the object
in focus on the screen.
Operation Instruction

3.Locate the scope between


thumb and index finger of your
other hand and fix the scope with
four fingers touching patient’s
forehead.
4. Instruct the patient to fix on
front or other angles according to
your diagnostic requirement.
5. Adjust the focusing wheel to
make the retina image in focus and
then press capture button to save
image.
Operation Instruction

Clinical Requirements for good retina image

1 Display opti disc and macular at the


same time
2 Micro Focus Adjustment:
Making veins show vividly.

3 ISO Gain adjustment:


Making enhanced contrast for images.
Operation Instruction

Problem shooting :

Problem Description Possible Reason Demo Photo

Good quality Normal


Image

The retina image is too The lens is too far from


small patient’s eye

There is white spot on The lens is too close to


the top of image the patient’s eye
Operation Instruction

Problem Shooting:
Problem Description Possible Reason Demo Photo

There is dark shade on The lens is above the


the top of image visual axis

There is dark shade on The lens is below the


the bottom of image visual axis

There is white line on The patient’s eyelash is


the image in front of the lens

There is blue or white There is reflection from


shade on the bottom of cornea
image
Operation Instruction

Album Check retina images


Data Transfer

HDMI connector

USB cable

WI-FI transfer SD CARD


Product Maintenance

1. Please don’t make lens dirty by finger print or dirt. Otherwise, the image quality
will be affected.
2.Please put the device with protecting cover back to the case after usage.
3 . Clean the lens
• Blow out dirt gently.
•Prepare solution made of Ethanol and Diethyl ether mixed at 2:8.
•Dip soft cloth to the solution mentioned above and clean the lens surface starting
from the center. You can clean it repeatedly if necessary. Please do not clean it
roughly to avoid scratch.
•If the lens is still dirty, please don’t clean it repeatedly to avoid damage on the
surface.
Operational Cautions
A . Settings
1.Time Setting
1 ) press setting>time >Automatic date&time>off
If you don’t select Off,you will not be able to set time and date.
2 ) Set date>Select date>Finish
3 ) Set time>Select time>Finish
Note: Please check if the current date and time is correct before using the device.
Otherwise, it will be difficult to find the new images you captured.(The system display the
images in time and date order.)

2.Fixation Light option


The function hasn’t been finished yet. If you press the icon,please press other place in
the screen to exit setting otherwise, you will be unable to build new patient file.

3.Flash Mode Setting


If you select off in the setting, you will not be able to shoot photos but you can shoot
videos in infrared illumination.
The usual setting is “on”, please don’t change it unless necessary.
Image Capture Techniques
1. Please ask patient to cover his another unexamined eye (In this case, both eyes are in the dark
environment making pupils relatively large).

2.When you press the capture button, please don’t move device and wait for 1 second to finish image
shooting.
Common Problem Shooting
1.Preview interface in black screen or unable to capture image

A. Please check if the connection between scope and main device is loose. Please hold the
scope and rotate it in clockwise direction thoroughly.
B. Check settings and see if Flash mode is “off”. Please make sure the flash mode is “on”.

2. The screen become black screen in short time after switch on the device
Check the Standby in settings and select longer standby time.
3. When you switch on the device and capture image but you did not find the image you
captured in any folder.
You must build up a new patient file before capture image, otherwise, the image will not be
saved.

4. You do not find images captured in your built patient file.


Please check if the current time and date on device is correct as the photos are displayed in
time order.

5. When there are more than 2 patient files in the device, how to check each patient file
respectively ?
Press image icon in the right down corner and enter album interface. You can check each
patient file in the album interface.

6. When you build up new patient file and press next, the device does not respond. In this case,
please press icon “▽”
Thank You