i. IS - Indian Standards.
Electrical Design:
• EB yard.
• HT yard.
• DG Room.
• MV Panel Room.
• Electrical Shaft.
• Communication Shaft.
• Cable Routing.
DRAWING REQUIREMENTS FROM
ARCHITECT’S
i. Site Plan.
Outdoor- 5 x 5 Mts.
Indoor - 5 x 6 Mts.
• RMU panel should be fenced at the height of 6 feet with front opening
door.
• For the outdoor, the RMU incoming HT cable must be bottom entry.
• For the indoor, the RMU outgoing HT cable must be top entry.
SPACE PLANNING-HT PANEL
• To be located next to RMU.
PF).
SPACE PLANNING – TRANSFORMER
• Types of Transformer
– Indoor Transformer
– Outdoor Transformer
Indoor Unit
Outdoor Unit
1.5Mts.
• Master Fuel tank and pumping should be consider for multi DG.
the cables.
• If two switch boards are erected adjacent to each other in the same
line, the clearance between the two switch boards must be more
than 750mm.
Cable
Cable
PVC XPLE
Cable Laying
• Types of Cable laying Outdoor unit
– Hume pipe
– Cable trench
– Raceway
– Conduit
• MS Conduit.
Distribution Boards (DB’s)
A Distribution board is used for dividing the electrical power and distribute
into subsidiary circuits with protective fuse or circuit breaker for each
circuit in a common enclosure.
DB
SPN TPN
• SPN (Single Phase And Neutral) DB :
No. of Ways :
4,6,8,12,16,18
Incomer :
• DP MCB
• DP Isolator
• DP RCCB
• DP RCBO
Outgoings:
• SP MCB
• TPN (Three Phase and Neutral) DB :
No. of Ways :
4,6,8,12 & 16
Incomer :
• FP MCB
• FP Isolator
• FP RCCB
• FP RCBO
Outgoings:
• SP MCB
• PPI (Per Phase Isolation) DB :
No. of Ways :
Horizontal - 4,6,8,12 & 16
Tier- 6,8,10,12 & 16
Incomer :
• FP MCB
• FP Isolator
• FP RCCB
• FP RCBO
Sub Incomer :
• DP RCCB
• DP RCBO
Outgoings:
• SP MCB
• TPN Phase Segregated DB
No. of Ways : MCCB Incomer:
4,6,8 & 12
• TP/FP MCCB
Modular Incomer :
• FP MCB Sub Incomer:
• FP Isolator • DP RCCB
• FP RCCB
Modular Incomer • DP RCBO
• FP RCBO
Sub Incomer : Outgoings:
• DP RCCB • SP MCB
• DP RCBO
Outgoings:
• SP MCB
MCCB Incomer
• Flexi / Row DB
No. of Ways :
Rows and Modular
Incomer :
• DP, FP MCB
• DP, FP Isolator
• DP ,FP RCCB
• DP,FP RCBO
Outgoings:
• SP, DP, TP MCB
• VTPN DB
No. of Ways :
4,6,8,12 & 16
Incomer :
• FP MCB
• FP Isolator
• FP RCCB
• FP RCBO
Outgoings:
• SP, TP MCB
Circuit Breaker (CB)
CB
Air Blast
MCB MCCB VCB ACB SF6 Bulk Oil Minimum Oil
Vacuum
Wiring
• Electrical Wiring
• Communication Wiring
• CCTV Wiring
• Nurse Calling bell Wiring
Electrical Wiring
A process of connecting various accessories for distribution of
Wiring.
FR - Flame Retardant
Wire Size:
0.75 4
1 6
1.5 10
16
2.5
Color in India:
Termination:
1)Lug
2)Connector
3) BLocks
Lug Size Image
Tubular Cable Lug
0.5 -0.75, 1.0-1.5, 2.5, 4,6, 10, 16, 25, 35,50, 70,
95, 120, 150, 185, 240, 300
provided.
TRANSFORMER – SPACE ALLOCATION
1.0
• The side clearance shall be 1Mt.
1.0 1.0
1.5 FRONT
DIESEL GENERATOR – SPACE ALLOCATION
1.5Mts.
be 1Mt.
• Hume pipe
• Cable trench
1.2Mts.
750mm.