START UP
C.01 Parameterization steps
PC with
Drive Monitor
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.02 Drives commissioning
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.03 Parameterization tools
PMU
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.04 PMU Unit
B0008
Raise/lower to
select:
B0009
Switch ON Parameters
P -----
Indices
Switch OFF B0006
Parameter B0007
values
B0005
Parameter number
Fault acknowledgement and
changeover between:
Parameter number
Parameter Parameter
index value
Parameter index
Parameter value
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.05 SIMOVERT MASTERDRIVES OPERATOR PANEL
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.06 OP1S
ADDRESSES
B2113
B2114
P -----
B2111
B2112
B2100
B2101
B2102
Reset B2107
Jo B2108
g
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.07 OP1S
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.08 SIEMENS MASTERDRIVES SW FOR DRIVE
COMMISSIONING AND MONITORING (Drive Monitor)
Customer
Features
benefits
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.09 Drive monitor start up
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.10 Drive monitor drive model selection
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.11 Drive monitor
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.12 Assisted commissioning
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.13 Drive monitor
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.14 Drive monitor
Parameter selected
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.15 Drive monitor- status of the drive
4 ON/OFF Command
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.16 DC Drives Parameterization steps
If the exact application condition of the unit is not known,
the parameter reset to the factory setting is suggested.
P051 = 21. Then the following procedure:
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C.18 DC Drives Block Diagram Overview
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.19 AC Drives Parameterization steps
• Board definition.
• Drive definition.
• Function adjustment.
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.20 Parameter reset to factory setting
The factory setting is the defined initial state of all parameters of a
unit. The parameters for defining the power section and for releasing
the technology options and the operating hours counter and fault
memory are not changed by a parameter reset to factory setting.
PROCEDURE
Grant parameter access
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.21 DRIVE CONFIGURATION BLOCK DIAGRAM
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.22 DRIVE CONFIGURATION BLOCK DIAGRAM
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.23 DRIVE CONFIGURATION BLOCK DIAGRAM
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.24 DRIVE CONFIGURATION BLOCK DIAGRAM
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.25 DRIVE CONFIGURATION BLOCK DIAGRAM
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.26 DRIVE CONFIGURATION BLOCK DIAGRAM
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.27 DRIVE CONFIGURATION BLOCK DIAGRAM
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.28 DRIVE CONFIGURATION BLOCK DIAGRAM
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.29 Drive definition
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.30 Calculation motor model
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.31 Free blocks parameterization
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.32 ProfiBus communication
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.33 ProfiBus communication
U734.01
U734.02
...
U734.10
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.34 R.R.U. unit
Rectifier/Regenerative Unit include same concepts of Master Drive.
“Control Words” and “Status Words” are still present. To parameterize,
two different procedures are available, the “standard application” and
the “Expert application”.
Control word 1 Control word 2
Bit 0 On Command Bit 16
Bit 1 OFF2 Pulse disable Bit 17
Bit 2 Always high Bit 18 RDS bit 0
Bit 3 Operating conditions Bit 19 RDS bit 1
Bit 4 Always high Bit 20
Bit 5 Always high Bit 21
Bit 6 Always high Bit 22
Bit 7 Edge fault acknowledgement Bit 23 12-pulse mode select
Bit 8 Inching bit 0 Bit 24
Bit 9 Inching bit 1 Bit 25
Bit 10 Control request Bit 26 External fault 2
Bit 11 Ud reduction request Bit 27 Master/slave drive
Bit 12 Regenerating enable Bit 28 External alarm 1
Bit 13 External fault 3 Bit 29 External alarm 2
Bit 14 Motoring Bit 30 Select BICO data set
Bit 15 External fault 1 Bit 31 HS Check back signal
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.35 R.R.U. parameterization “standard application”
P050 = Language
Operator control
Commands Yes
via OP1?
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.36 R.R.U. parameterization “standard application”
Mode variants
Regen. No
Transformer?
Yes
No Permanent
reduction?
Yes
DC link forming
Idle time Yes
of converter
>1 year
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.37 R.R.U. parameterization “standard application”
DC link forming
P052 =20
P Key Function selection 20 = forming of DC link
Switch-on
Forming
Wait to
Ud<50V
Circuit identification
Identification
Acknowledge
Function selection 21 = Circuit identification
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.38 R.R.U. parameterization “standard application”
Circuit identification
Eliminate
Cause of fault
Yes
Fault message
Logbook
Ready
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.39 R.R.U. parameterization “expert mode”
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.40 Technology Board
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved
C. START UP
C.41 Process data exchange
This document contains proprietary information of Danieli Automation S.p.A. not disclosable, not reproducible. All Rights Reserved