Security Level:

Power Control III

Algorithm and Parameters

www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


HW III Power Control Flow

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 2


HW III Power Control Main Changes

The difference of HW II and HW III Power Control algorithm are:

• Initial Discarded MR. number


At the initial stage of channel seizure, the MR data is considered unstable/
fluctuating. So to avoid Power Control inaccuracy, system discards some
initial measurement reports.
In HWII: Discards 4 initial MR (fixed)
In HWIII: Set by parameter- Signal/Traffic Channel Discard MR Number

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 3


HW III Power Control Main Changes
• MR Interpolation Method
The interpolation for lost values in the missing Measurement Reports are
optimized.

MR1 MRX MRX MR4 MR5

In HWIII, the interpolation value is as below:


If the Rx Level value is lost, the recovered value for missing MR is taken
from the last measurement report.
RxLev (MRX) = RxLev (MR1)
If Rx Quality is lost, the interpolation value is 7.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 4


HW III Power Control Main Changes
• MR Filtering
In HWIII, the receive quality is converted to carrier-to-interference
(C/I). The mapping is as below:

Then the C/I and the Receive Level shall be filtered using Exponential
filter and slide window.
In HW II, filtering is based on mean value filtering.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 5


HW III Power Control Main Changes
• MR Filtering
Exponential Filtering:
Receive Level

Receive Quality

Where: k= serial number of MR

a= exponential filter coefficient = 1/ (2W/2); where w= exponent filter length parameter

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 6


HW III Power Control Main Changes
• MR Filtering
After Exponential Filtering, the result will be considered in the sliding
window:

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 7


HW III Power Control
• BTS Power Control Step Calculation
In HWII, power control decisions of the receive level and receive quality are
performed separately. The final decision is performed based on separate decisions.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 8


HW III Power Control
• Power Control Step Calculation
In HWIII, a universal decision formula that considers the receive level
and receive quality is performed.
Step (k) = - {sfactor * (Bs/Ms TxMaxPower – g(k) – SThr) + q factor* (qa_filtered (k) + Q0ffFh –
Qthr)}
Sfactor= HWIII DL RexLev Adjust Factor
Qfactor= HWIII DL Rex Qual Adjust Factor
SThr = (SThrUp + SThrLow)/2
QThr = (QThrUp + QThrLow)/2
qa_filtered (k)= MR filtered receive quality converted to C/I
Q0ffFh= Frequancy hopping gain

g(k)= gain of radio channel (Pathloss of the channel)

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 9


HW III Power Control
Example:

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 12


HW III Power Control
Example:

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 13


Thank you
www.huawei.com

You might also like