Professional Documents
Culture Documents
BSC6900V900R011 UO Global and Equipment Data Configuration Issue1.0
BSC6900V900R011 UO Global and Equipment Data Configuration Issue1.0
www.huawei.com
BSC6900V900R011
RAN technology service dept.
configuration of BSC6900
Master global data configuration
Guide 》
After the BSC6900 is initially installed, prepare and configure data based on
the hardware configuration of the BSC6900, network planning, and
negotiation between the RNC and other equipment. Then, you can obtain an
MML script in .txt format.
The data in the MML script must be complete, consistent, and valid. After
the script is executed, a data file is generated and then loaded onto the RNC
host. The RNC then starts to work properly. For details, refer to the RNC
Commissioning Guide.
Deployment
During the deployment, engineers should configure BSC6900 data
configuration script according to the negotiation data for stand alone
BSC6900 during initial setup and run the script by MML commands in
batches.
Modify data in batch mode
When the RNP or RNO engineers need to modify mass incumbent
BSC6900 configuration data, they can modify BSC6900 configuration
data through running MML command script in batch mode.
Modify a few configuration data
When a few configuration data need to be modified, every single MML
command can be run to execute the function.
Action Meaning
ADD Add an object
SET Set an object
LST Query BAM database configuration information
DSP Query FAM object state or BAM running state
MOD Modify an object
RMV Remove an object
ACT Activate an object
DEA Deactivate an object
RST Reset an object
Start UTRAN
UE CN
Uu Iu
BSC6900
Global data
Iub
configuration
NodeB
MSC Server
Equipment data b
Iu
configuration Iu-CS
Iur
Interface data
configuration NodeB
MGW
Iu-PS
configuration
NodeB SGSN
BSC6900
End
Start
Start
End
NMSI
EPS
BAM BAM 80.x.x.x
External Internal
SCU
EPS
This command is an optional one, in which Scenario will it be used to modify the parameters?
Start
End
Network ID:
INT: international network 14byte
INTB: international reserved 24byte
NAT: national network 24byte
NATB: national reserved 14byte
ACT LICENSE:;
Adding RNC global location
SET LICENSE:;
End
Start
End
PLMN value tag: different value ranges should be allocated to the PLMN value
tags of any two geographically neighboring areas.
Start
End
Adding an EMU
Adding an EMU
SET MSP:;
Adding an EMU
The SCUa has been configured, when the
Configuring RNC Clock Data subrack added, and the boards cannot be
deleted. The GCUa/GCGa has been
Setting RNC Time
configured in MPS, and the boards cannot
Adding the IP Address of the EMS Server be deleted.
Adding an EMU
ADD EMU:;
Adding an EMU
The clock source of the interface board in the EPS cannot be set to the 8 kHz
output clock source.
These kinds of boards AEU,AOU,UOI_ATM,PEU,POU,UOI_IP, can use any link
as a output clock source.
1 (Top priority)
2 (High priority)
3 (Low priority)
4 (Lower priority)
0 (Lowest priority =Local Clock)
BITS1-2MHZ
BITS2-2MHZ Can be get from interface board or external clock source such as BITS
BITS1-2MBPS
BITS2-2MBPS
8KHZ Is the independent clock source and input from com1 of GCUa board
LINE1-8KHZ provide two channels of 8 kHz clock signals that are locked
LINE2-8KHZ at the interface boards and transported to the backplane.
Configure Subracks Data If RNC get time information from core
network through SNTP server, the SNTP
Configure boards Data
Client information must be set.
Adding an EMU