Professional Documents
Culture Documents
Unomedical Airway Management
Unomedical Airway Management
Airway Management
Safety • Functionality • Reliability
Unomedical Airway Management
Anaesthesia
Respiratory Suctioning
Specimen collection
2
Unomedical Airway Management
Respiratory products
Oxygen Masks
& Cannulas
Resuscitators 3
Unomedical Airway Management
Anaesthesia products
Endotracheal Tracheostomy
Tubes Tubes
Laryngeal
Airways
4
Unomedical Airway Management
Suction & specimen collection
Specimen
collection
5
Resuscitators
Endotracheal Tubes
Standard
Tracheostomy
Tubes
Open Suction
Catheters 6
Unomedical Endotracheal Tubes
7
Unomedical Endotracheal Tubes
8
Unomedical ETT Suction
9
Safety, Functionality, Reliability
Safety
Easy identification
Improved position control
Effective seal (HVLP Cuff)
Atraumacitic transition
Functionality
Unomedical Colour Coding
Perfect adaptation
Accurate positioning
Radiopaque
RELIABILITY
10
Unomedical Tracheostomy Tubes
11
Unomedical Tracheostomy Tubes
12
Safety, Functionality, Reliability
Safety
Gentle adaptation
Reduced risk of displacement
Atraumatic transition
Effective seal
Easy indentification & traceability
Functionality
Unomedical Colour Coding
Thermosensitive & Transparent
Suitable for percutaneous insertion
Wide range of solutions
RELIABILITY
13
Unomedical TTIC Suction
Subglottic
room
Glottic
opening
Cuff
1
Mahul et al.: “Prevention of nosocomial pneumonia in intubated patients:respective role of mechanical subglottic secretions drainage and
stress ulcer prophylaxis.“ Intensive Care Med 1992, 18:20-25.
1
Valles et al.: “Continuous aspiration of subglottic secretions in preventing ventilator-associated pneumonia.” Ann Intern Med 1995, 122:179-186
1 Smulders et al.: “A randomized clinical trial of intermittent subglottic secretion drainage in patients receiving mechanical ventilation.”
Chest 2002, 121:858-862 14
Cathy Closed Suction System
TM
TM
17
Cathy Closed Suction System
TM
TM
Safety
Control button
Indication of Built-in non- Slim semi- with safety lid
open/closed return valve transparent
Universal
position protective Unomedical
connector
sleeve Colour Coding
Disconnecting
ring
RELIABILITY
18
Assess, identify, formulate
19
Assess, identify, formulate
Cathy Cathy
vs vs
Open Suction Closed Suction
20
Assess, identify, formulate
End-user Clinician
Nurse
Influencer Purchaser
Clinician
Nurse
21
Assess, identify, formulate
End-user Nurse
Influencer Nurse
22
Endotracheal Suctioning
Background:
Endotracheal suctioning is able to create extremely high
flows that are potentially able to eliminate the complete
volume delivered to the lungs by the ventilator
Stenqvist O, Lindgren S, Karason S, Sondergaard S, Lundin S. Warning! Suctioning. A lung model evaluation of closed suctioning systems. Acta anaesthesiologica Scandinavica VOL:45(2); p.167-72/2001
Almgren B, Wickerts CJ, Heinonen E, Hogman M. Side effects of endotracheal suction in pressure- and volume controlled ventilation. Chest 2004;125:1077-80
Almgren, B; Endotracheal Suction a Reopened Problem. Acta Universitatis Upsaliensis. Digital Comprehensive Summaries of Uppsalla Dissertations from the Faculty of Medicine 11.55pp. Uppsala; 2005
AARC Clinical Practice Guideline. Endotracheal Suctioning of Mechanically Ventilated Adults and Children with Artificial Airways. Respir Care 1993;38:500-504 23
What are nurses saying?
Endotracheal suctioning is very physical
Wrong sized suction catheters
Need to use “end-feel” to estimate depth of catheter insertion
Short time-frame for suctioning ventilated patient
24
Cathy Closed Suction System
TM
TM
Safety
Control button
Indication of Built-in non- Slim semi- with safety lid
open/closed return valve transparent
Universal
position protective Unomedical
connector
sleeve Colour Coding
Disconnecting
ring
RELIABILITY
25
Disconnection ring
Turn in the
direction of the arrows
27
Filter protection
55µm
µmhydrophobic
hydrophobicfilter
filter
30
Mülly-tip catheter with metric markings
••The
Thespecially
speciallydesigned
designedMülly
Müllytip
tipcatheter
catheterhelps
helps
to prevent mucosa trauma
to prevent mucosa trauma
••The
TheMülly
Müllycatheter
catheteris
isdesigned
designedwith
with22small
small
relieving
relievingeyes
eyesand
andaafull
fullbore
boredistal
distaleye
eye
36
Mucosa trauma
• High vacuum
• Design of catheter
37
Unomedical Colour Coding System
41
42
Unomedical
Airway Management
Safety • Functionality • Reliability