BOILE
R
a closed vessel into which water is heated until the water is converted into steam at required
pressure.
Application of boiler in
garment industry
It is used for
◦ Fibre production
◦ Weaving
◦ Dyeing
◦ Drying
◦ Ironing
◦ Printing
◦ Heating the equipment
◦ Maintaining the temperature of
system
Issues faced by boilers in
garment industry
• Boiler needs time to heat up before it starts producing steam, daily a lot of
time is wasted in heating up of boiler
• It is prone to corrosion on high temperature , we have to keep track of the
temperature and if we fail to do so the boiler is corroded.

Solution
◦ If we could heat up the boiler before hand we could save time and
increase production
◦ If the boiler could get cut off automatically and could report any emergency
situation on its own , the worker can do another work too and we would increase
equipment life.
Objective
• Able to monitor temperature to lessen the corrosion of the
boiler.

• Able to turn it on before hand wirelessly

(Not possible on TinkerCAD AS There is no Bluetooth or WIFI


component )
Components
required

Arduino Jumper Temperature Cable A to Distance


UNO Wires Sensor B Sensor

Breadboar LCD panel Resisto Buzze


d 16*2 r r
Circuit CLICK FOR
SIMULATION

diagram Click here for simulati


on
Circuit diagram
Explanation
• Here, we have used DC motor instead of boiler to provide simulation.

• The temperature sensor senses the temperature of water inside the boiler.

• At 100^C water boils and it needs further more heat to get converted into steam .

• At 120^C and above it starts becoming dangerous and gets more prone to corrosion.

• Hence, It is coded in such a way that DC motor will be active until the temperature is
119^C as temperature goes 120^C and above DC motor stops , buzzer beeps , LED glows
indicating emergency sign.
Star
t
Set LCD
(16,2)
For display

Set pin A0
for input
For temp sensor

Set pin 7 and 13


for output
Circuit For buzzer and LED

Set DC motor
diagram for output

flowchart Calculat
e
current
temperature
No If Yes
Turn Pin 7 buzzer off temp Turn Pin 7 buzzer on
>1
20
Turn Pin 13 LED off Turn Pin 13 LED on

Turn Pin motor on Turn Pin motor off

Display temp. and Display temp. and


on off

Sto
By Implementing
this..
◦ Decreasing SMV (Production time).
◦ Increase in production.
◦ Decrease in labor as in big industries one man is needed to take care of
boiler.
◦ Decreased chances of hazards.
◦ Increased Equipment Life.
◦ Decreased electricity consumption.