Summary

 Progress:
• Total Bad spot : 32
• Total Cluster POI : 21 (14 Cluster “closed”, 2 Cluster “Park”, 5 Cluster still “open”)
for the details kindly see the attached file
Cluster POI Spot DT Baseline DT Baseline Date Optimization DT Bad spot After DT Bad spot After Date Status Remark
Sarijadi Spot #1 Done 02-Oct-14 Done     Park SARIJADIMW issue
Spot #1 Done Done Done Week 44 Closed improved
University(UPI) Spot #2 Done 06-Oct-14 Done     Open  
Spot #3 Done Done Done Week 44 Closed improved
Spot #1 Done Done Done Week 42 Closed improved
CIUMBULEUIT 06-Oct-14
Spot #2 Done Done Done Week 42 Closed improved
Spot #1 Done Done Done Week 42 Closed improved
Cihampelas 09-Oct-14
Spot #2 Done Done Done Week 42 Closed improved
Spot #1 Done Done     Open  
Siliwangi (TIB) Spot #2 Done 03-Oct-14 Done Done Week 43 Closed improved
Spot #3 Done Done     Open  
Dipatu Ukur Spot #1 Done 03-Oct-14 Done Done Week 43 Closed improved
Spot #1 Done Done Done Week 43 Closed improved
Jalan Progo 09-Oct-14
Spot #2 Done Done Done Week 43 Closed improved
PVJ   Done 08-Oct-14 Done     Closed improved
Spot #1 Done Done     Open  
BEC 07-Oct-14
Spot #2 Done Done     Open  
Spot #1 Done Done Done Week 43 Closed Improved
Pasteur 08-Oct-14
Spot #2 Done Done   Week 43 Open  
Spot #1 Done Done   Week 43 Open  
Sarijadi Road 02-Oct-14
Spot #2 Done Done     Park SARIJADIMW issue
Spot #1 Done PASIRKALIKIMW
Gardujati 01-Oct-14 Done   Week 43 Open Issue
Spot #2 Done Done Done Week 43 Closed improved
Pasar Baru Spot #1 Done 07-Oct-14 Done Done Week 42 Closed improved
Kalipah Apo- Spot #1 Done Done Done Week 43 Closed improved
07-Oct-14
Kepatihan Spot #2 Done Done Done Week 43 Closed improved
Asia Afrika Road   Done 09-Oct-14 Done     Closed Throughput no issue
JL Martadinata-RIAU Spot #1 Done 07-Oct-14 Done Done Week 43 Closed improved
3G WJ CET Cluster
Taman Lalu Lintas- Spot #1 Done
01-Oct-14
Done     Open   POI_Throughput_W43_2014
BIP Spot #2 Done Done     Open  
Spot #1 Done Done Done Week 42 Closed improved
STATION 01-Oct-14
Spot #2 Done Done Done Week 42 Closed improved
Festival City Link   Done 08-Oct-14 Done     Closed Throughput no issue
Maleer Spot #1 Done 09-Oct-14 Done Done week 43 Closed improved
Antapani Spot #1 Done 09-Oct-14 Done Done week 44 Closed improved

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 2


Cluster POI CIUMBULEUIT

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 3


3
Cluster POI CIUMBULEUIT_Bad spot distribution

Spot 1

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 4


Cluster POI CIUMBULEUIT_Spot 1

BEFORE AFTER ► Analysis :


Problem Found:
• Serving cell fromJLCIKENDIMW1
• Low trhoughput by cell JLCIKENDIMW1
• HSPDSCHCodeNum current setting of
cell JLCIKENDIMW1 is "manual=1",
• Missing neighbor from
CIUMBULEUITMX2 to RSAUMW2

► Action:
• Modify HSPDSCHCodeNum From
"manual=1" to "automatic, min=5,
max=10"
• Audit neighbors

► DT Date : week 42

► Result : Throughput better than before

► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 5


Cluster POI CIUMBULEUIT_ Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 628.247 Kbps 873.502 Kbps
Maximum 1830.07 Kbps 1955.88 Kbps
Minimum 76.76 Kbps 172.83 Kbps
[0,56) 0 0
[56,128) 1 0
[128,256) 7 2
[256,512) 7 5
[512,1024) 16 27
[1024,2048) 5 12

[2048,14336) 0 0

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 6


Cluster POI CIHAMPELAS

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 7


7
Cluster POI CIHAMPELAS _Bad spot distribution

Spot 1

Spot 2

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 8


Cluster POI CIHAMPELAS _Spot 1

BEFORE AFTER ► Analysis :


Problem Found:
• Serving Cell from
CIHAMPELASMZ3,ITBMZ3,PARISVANJ
AVA2MZ4,JLJURANGMX2,CMBPAJAJA
RANMW1
• DL Power Congestion by cell
CMBPAJAJARANMW1
• HSPDSCHCodeNum current setting of
cell PARISVANJAVA2MZ4,
CMBPAJAJARANMW1 are "manual=1"
• Missing Neighbor from JLJURANGMX2
to PARISVANJAVA2MX4

► Action:
• Decrease CPICHPower cell
CMBPAJAJARANMW1 (current value is
343)
• Audit neighbors
• Modify HSPDSCHCodeNum of all
serving cell from "manual=1" to
"automatic, min=5, max=10"

► DT Date : week 41

► Result : Throughput better than before

► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 9


Cluster POI CIHAMPELAS _ Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 2984.22 Kbps 3102.72 Kbps
Maximum 8087.64 Kbps 6047.36 Kbps
Minimum 203.7Kbps 553.07Kbps
[0,56) 0 0
[56,128) 14 2
[128,256) 19 9
[256,512) 25 15
[512,1024) 21 33
[1024,2048) 27 61

[2048,14336) 44 111

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 10


Cluster POI CIHAMPELAS _Spot 2

BEFORE AFTER ► Analysis :


Problem Found:
• Serving Cell from
UNPASTMNSARIMW3,
RAMSTAILORMW1,
CMBPAJAJARANMW1
• HSPDSCHCodeNum current setting of
cell
RAMSTAILORMW1,CMBPAJAJARANM
W1 are "manual=1"
• DL Power Congestion by cell
CMBPAJAJARANMW1
► Action:
• Decrease CPICHPower
CMBPAJAJARANMW1 from 343 to 330
• Modify HSPDSCHCodeNum of cell
PARISVANJAVA2MZ4,
CMBPAJAJARANMW1 and
UNPASTMNSARIMW3 from "manual=1"
to Automatic, min=5, max=10"
• Audit Neighbors

► DT Date : week 41

► Result : Throughput better than before

► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 11


Cluster POI CIHAMPELAS _ Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 1737.32 Kbps 2408.88 Kbps
Maximum 7429.11 Kbps 7429.11 Kbps
Minimum 57.71 Kbps 57.58 Kbps
[0,56) 0 0
[56,128) 14 2
[128,256) 19 9
[256,512) 25 15
[512,1024) 21 33
[1024,2048) 27 61

[2048,14336) 44 111

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 12


Cluster POI DIPATIUKUR

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 13


13
Cluster POI DIPATIUKUR _Bad spot distribution

Spot 1

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 14


Cluster POI DIPATIUKUR_spot 1

BEFORE AFTER ► Analysis :


Problem Found:
• Serving cell from
RSBORROMEUSMW2,MSJSALMANITB
MW
• - HSPDSCHcodenum of
MSJSALMANITBMW and
RSBORROMEUSMW is "manual=1"
• Uplink CE Congestion, HSUPA user
cogestion, UL Power Congestion by cell
RSBORROMEUSMW2

► Action:
• Modify HSPDSCHcodenum of
MSJSALMANITBMW and
RSBORROMEUSMW from "manual=1"
to "automatic,min=5, max=10"
• Upgrade CE Licene of
RSBORROMEUSMW
• Modify UCELLCAC
RSBORROMEUSMW
(ULTOTALEQUSERNUM) from 160 to
200

► DT Date : week 43

► Result : Better than before

► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 15


Cluster POI DIPATIUKUR _ Statistic
TELKOMSEL Before TELKOMSEL After
Element RLC SDU Throughput DL_All Logs
Average 921.25 Kbps 933.809 Kbps
Maximum 2041.09 Kbps 1619.73 Kbps
Minimum 65.25 Kbps 96.02 Kbps
[0,56) 0 0
[56,128) 1 1
[128,256) 1 0
[256,512) 3 1
[512,1024) 3 4
[1024,2048) 6 4

[2048,14336) 0 0

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 16


Cluster POI JALAN PROGO

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 17


17
Cluster POI JALAN PROGO_ Bad spot distribution

Spot 1

Spot 2

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 18


Cluster POI JALAN PROGO_spot 1

BEFORE AFTER ► Analysis :


Problem Found:
• Serving cell from HTLSERELLAMX1,
JLPROGOMX1, MARTADINATAMX1
• HSPDSCHCodeNum current setting of
cell HTLSERELLAMX1 is "manual=1"
• Overshooting by cell HTLSERELLAMW1

► Action:
• Modify HSPDSCHCodeNum From
"manual=1" to "automatic, min=5,
max=10“

► DT Date : Week 43

► Result : Better than before

► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 19


Cluster POI JALAN PROGO_spot 2

BEFORE AFTER ► Analysis :


Problem Found:
• Serving Cell from HTLSERELLAMX1,
MARTADINATAMX2
• Overshooting by cell HTLSERELLAMW1
• HSPDSCHCodeNum current setting of
cell HTLSERELLAMX1 is "manual=1“

► Action:
• Modify HSPDSCHCodeNum of
HTLSERELLAMW, MARTADINATAMW
• From "manual=1" to "automatic, min=5,
max=10“

► DT Date : week 43

► Result : Better than before

► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 20


Cluster POI JALAN PROGO_ Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 551.817 Kbps 2014.38 Kbps
Maximum 2163.86 Kbps 5206.58 Kbps
Minimum 60.94 Kbps 368.71 Kbps
[0,56) 0 0
[56,128) 22 0
[128,256) 38 0
[256,512) 83 2
[512,1024) 63 18
[1024,2048) 32 52
[2048,14336) 1 64

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 21


Cluster POI PVJ

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 22


22
Cluster POI PVJ _Bad spot distribution

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 23


Cluster POI PVJ _ Statistic
TELKOMSEL
Element RLC SDU Throughput DL_All Logs
Average 3760.45 Kbps
Maximum 8763.45 Kbps
Minimum 57.60 Kbps
[0,56) 0
[56,128) 2
[128,256) 6
[256,512) 3
[512,1024) 15
[1024,2048) 44
[2048,14336) 231
[14336,58000] 0
Sum Total 301

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 24


Cluster POI PASAR BARU

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 25


25
Cluster POI PASAR BARU_Bad spot distribution

Spot 1

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 26


Cluster POI PASAR BARU_Spot 1

BEFORE AFTER ► Analysis :


Problem Found:
• Serving cell from
JASAARTHAMZ3,HTLPERDANAMZ1,B
ALONGGEDEMW1
• HSDPDSCHcodenum current setting of
cell JASAARTHAMZ3 is "manual=1"
• Missing neighbor from cell
HTLPERDANAMW1 to
BALONGGEDEMW1

► Action:
• Modify HSPDSCHcodenum of
JASAARTHAMZ from "manual=1" to
"automatic,min=5, max=10"
• Audit neighbors

► DT Date : week 42

► Result : Better than before

► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 27


Cluster POI PASAR BARU_ Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 727.465 Kbps 1406.47 Kbps
Maximum 4763.58 Kbps 4770.93 Kbps
Minimum 53.77 Kbps 143.64 Kbps
[0,56) 1 0
[56,128) 20 0
[128,256) 34 4
[256,512) 31 19
[512,1024) 21 38
[1024,2048) 13 66
[2048,14336) 14 33

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 28


Cluster POI KALIPAH APO_KEPATIHAN

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 29


29
Cluster POI KALIPAH APO_KEPATIHAN_Bad Spot distribution

Spot 1

Spot 2

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 30


Cluster POI KALIPAH APO_KEPATIHAN_Spot 1

BEFORE AFTER ► Analysis :


Problem Found:
• Serving cell from
PLAZAPARAHYANGANMZ2,PUNGKUR
MZ1
• PDSCHCodenum
PLAZAPARAHYANGANMW is
"manual=1"
• There are ULCECongestion
PLAZAPARAHYANGANMW

► Action:
• Modify PDSCHCodenum
PLAZAPARAHYANGANM from
"manual=1" to
"automatic,min=5,max=10"
• Upgrade ULCECongestion
PLAZAPARAHYANGANMW

► DT Date : week 43

► Result : Better than before

► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 31


Cluster POI KALIPAH APO_KEPATIHAN_ Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 574.967 Kbps 1021.18 Kbps
Maximum 1884.17 Kbps 2642.47 Kbps
Minimum 92.17 Kbps 153.63 Kbps
[0,56) 0 0
[56,128) 1 0
[128,256) 12 6
[256,512) 26 14
[512,1024) 16 18
[1024,2048) 10 23

[2048,14336) 0 6

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 32


Cluster POI KALIPAH APO_KEPATIHAN_Spot 2

BEFORE AFTER ► Analysis :


Problem Found:
• Serving cell from
HTLPERDANAMZ2,HTLPERDANAMZ1,
PLAZAPARAHYANGAMZ3
• PDSCHCodenum
PLAZAPARAHYANGANMW is
"manual=1"
• HTLPERDANAMW high user congestion

► Action:
• Modify PDSCHCodenum
PLAZAPARAHYANGANM from
"manual=1" to
"automatic,min=5,max=10“

► DT Date : week 43

► Result : Better than before

► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 33


Cluster POI KALIPAH APO_KEPATIHAN_ Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 1075.85 Kbps 1469.07 Kbps
Maximum 5613.81 Kbps 305343 Kbps
Minimum 57.61 Kbps 349.51 Kbps
[0,56) 0 0
[56,128) 24 0
[128,256) 34 0
[256,512) 27 4
[512,1024) 7 31
[1024,2048) 13 62
[2048,14336) 27 24

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 34


Cluster POI ASIA AFRIKA

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 35


35
Cluster POI KALIPAH ASIA AFRIKA_Bad spot distribution

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 36


Cluster POI ASIA AFRIKA_ Statistic
TELKOMSEL Before

Element RLC SDU Throughput DL_All


Logs
Average 2348.28 Kbps
Maximum 7935.57 Kbps
Minimum 84.44 Kbps
[0,56) 0
[56,128) 3
[128,256) 2
[256,512) 20
[512,1024) 77
[1024,2048) 208
[2048,14336) 277
[14336,58000] 0
Sum Total 587

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 37


Cluster POI JL Martadinata-RIAU

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 38


38
Cluster POI JL Martadinata-RIAU_Bad spot distribution

Spot 1

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 39


Cluster POI JL Martadinata-RIAU_Spot 1

BEFORE AFTER ► Analysis :


Problem Found:
• Serving cell from
TMPRAMUKAMW3,PLAZAIBCCMW1,S
RIGADINGMW1
• DLPowerCongestion from cell
TMPRAMUKAMW3,PLAZAIBCCMW1,S
RIGADINGMW1
• ULPowerCongestion from cell
TMPRAMUKAMW3,PLAZAIBCCMW1,S
RIGADINGMW1
• HSUPAUser Congestion from cell
TMPRAMUKAMW3,PLAZAIBCCMW1,S
RIGADINGMW1

► Action:
• 'Modify PDSCHCodeNum ​of
TMPRAMUKAMW3 from "manual=1" to
"automatic,min=5,max=10"
• Modify UPCPICHPower of
PLAZAIBCCMW from 343 to 330

► DT Date : week 43

► Result : Better than before

► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 40


Cluster POI JL Martadinata-RIAU_Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 893.164 Kbps 1165.9 Kbps
Maximum 3754.73 Kbps 2349 Kbps
Minimum 61.45 Kbps 222.76 Kbps
[0,56) 0 0
[56,128) 12 0
[128,256) 12 1
[256,512) 4 2
[512,1024) 4 13
[1024,2048) 6 21

[2048,14336) 9 2

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 41


Cluster POI STATION

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 42


42
Cluster POI STATION_Bad spot distribution

Spot 1

Spot 2

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 43


Cluster POI STATION_Spot 1

BEFORE AFTER ► Analysis :


Problem Found:
• serving cell by BALAIKOTABDGMW
• HSDPA User congestion by
BALAIKOTABDGMW
• DL Power Cong by BALAIKOTABDGMW
• Pdschceodenum manual=1 by
BALAIKOTABDGMW

► Action:
• Modufy UCELLCAC (HSDPAmax user to
96)
• Decrease PCPICH from 360 to 343
• Modify PDSCHCodeNum from
"manual=1" to Automatic, min=5,
max=10“

► DT Date : week 42

► Result : Better than before

► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 44


Cluster POI STATION_Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 1442.1 Kbps 1773.6 Kbps
Maximum 3948.08 Kbps 5060.06 Kbps
Minimum 53.73 Kbps 199.58 Kbps
[0,56) 2 0
[56,128) 4 0
[128,256) 0 2
[256,512) 2 2
[512,1024) 0 6
[1024,2048) 5 8
[2048,14336) 5 8

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 45


Cluster POI STATION_Spot 2

BEFORE AFTER ► Analysis :


Problem Found:
• Serving cell by DULATIPMW and
JLHMESRIMW
• OSS KPIs DULATIP in good condition
• HSPDSCHcodenum of DULATIPMW is
"automatic, min=5,max=10"
• HSPDSCHcodenum of JLHMESRIMW is
"manual=1“

► Action:
• Modify HSPDSCHcodenum of
JLHMESRIMW from "manual=1" to
"automatic,min=5, max=10“

► DT Date : week 42

► Result : Better than before

► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 46


Cluster POI STATION_Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 1566.5 Kbps 3737.29 Kbps
Maximum 7424.88 Kbps 6878.87 Kbps
Minimum 53.77 Kbps 1175.72 Kbps
[0,56) 1 0
[56,128) 4 0
[128,256) 6 0
[256,512) 17 0
[512,1024) 9 0
[1024,2048) 1 15
[2048,14336) 14 48

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 47


Cluster POI FESTIVAL CITY LINK

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 48


48
Cluster POI FESTIVAL CITY LINK_Bad spot distribution

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 49


Cluster POI FESTIVAL CITY LINK_Statistic
TELKOMSEL Before

Element RLC SDU Throughput


DL_All Logs
Average 4505.14kbit/s
Maximum 8956.38kbit/s
Minimum 56.53kbit/s
[0,56) 0
[56,128) 1
[128,256) 0
[256,512) 0
[512,1024) 4
[1024,2048) 27
[2048,14336) 273
[14336,58000] 0
Sum Total 305

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 50


Cluster POI ATLAS_ANTAPANI

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 51


51
Cluster POI ANTAPANI_Bad spot distribution

Area Badspot

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 52


Cluster POI ANTAPANI_BadSpot (COMPARISON BEFORE VS AFTER)

BEFORE AFTER ► Analysis :


Problem Found:
• Serving cell from
SARIINDAHMW2,MOHTOHAMZ1,SARII
NDAHMX3,SETRAWANGIMZ2,BABAKA
NSARIMZ1,AT
• LASNTAPANIMZ3,JLKAMPUSMW1
ULCE congestion from cell
BABAKANSARIMW, current ULCE
license is 768, use 2 WBBPD2
• Bad ecno due to pollutant
► Suggestion
• Need add WBBP Board
• Physical tuning BABAKANSARIMW to make
dominant server
► Action:
• Escalated to RNP team to upgrade or
add board WBBP
► DT Date : week 44

► Result : Better than before

► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 53


Cluster POI ANTAPANI_Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 1275.11 Kbps 3563.78 Kbps
Maximum 8482.89 Kbps 8202.75 Kbps
Minimum 51.61 Kbps 76.81 Kbps
[0,56) 2 0
[56,128) 66 2
[128,256) 44 4
[256,512) 140 14
[512,1024) 88 29
[1024,2048) 78 91
[2048,14336) 99 360

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 54


Cluster POI GARDUJATI

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 55


55
Cluster POI GARDUJATI_Bad spot distribution

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 56


Cluster POI GARDUJATI_Spot 1

BEFORE AFTER
Spot 1

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 57


Cluster POI GARDUJATI_BadSpot (COMPARISON BEFORE VS AFTER
► Analysis :
Cluster POI GARDUJATI_Statistic Problem Found:
• Serving Cell from PASIRKALIKIMZ2,
TELKOMSEL Before TELKOMSEL After current of HSDPSCHCodeNum is
Element RLC SDU Throughput DL_All Logs "manual=1"
Average 2483.52 Kbps 2834.89 Kbps • There are congestion
Maximum 9163.16 Kbps 9163.16 Kbps (CE,Power,Code,User) since 17 October
Minimum 10.58 Kbps 88.33 Kbps 2014
• Overshoot from cell PASIRKALIKIMW2
[0,56) 1 0
since 17 October 2014
[56,128) 2 0 ► Suggestion
[128,256) 5 0 • Modify HSDPSCHCodeNum of PASIRKALIKIM
[256,512) 8 3 from "manual=1" to "automatic,
[512,1024) 16 21 min=5,max=10"
[1024,2048) 40 51 • Downtilt PASIRKALIKIMW2 to reduce
overshoot
[2048,14336) 61 90 ► Action:
• Modify HSDPSCHCodeNum of
[14336,58000] 0 0 PASIRKALIKIM from "manual=1" to
"automatic, min=5,max=10"
• Downtilt PASIRKALIKIMW2 from Az120
M2E2 to Az120 M2E4
► DT Date : week 44

► Result : Better than before

► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 58


Cluster POI GARDUJATI_Spot 2

BEFORE AFTER

Spot 2

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 59


Cluster POI GARDUJATI_BadSpot (COMPARISON BEFORE VS AFTER
► Analysis :
Cluster POI GARDUJATI_Statistic Problem Found:
• Serving Cell from PASIRKALIKIMZ2,
TELKOMSEL Before TELKOMSEL After current of HSDPSCHCodeNum is
Element RLC SDU Throughput DL_All Logs "manual=1"
Average 3374.15 Kbps 3427.32 Kbps • There are congestion
Maximum 9163.16 Kbps 9163.16 Kbps (CE,Power,Code,User) since 17 October
Minimum 10.58 Kbps 88.33 Kbps 2014
• Overshoot from cell PASIRKALIKIMW2
[0,56) 7 3
since 17 October 2014
[56,128) 7 6 ► Suggestion
[128,256) 13 13 • Modify HSDPSCHCodeNum of PASIRKALIKIM
[256,512) 27 27 from "manual=1" to "automatic,
[512,1024) 70 71 min=5,max=10"
[1024,2048) 190 216 • Downtilt PASIRKALIKIMW2 to reduce
overshoot
[2048,14336) 507 532 ► Action:
• Modify HSDPSCHCodeNum of
[14336,58000] 0 0 PASIRKALIKIM from "manual=1" to
"automatic, min=5,max=10"
• Downtilt PASIRKALIKIMW2 from Az120
M2E2 to Az120 M2E4
► DT Date : week 44

► Result : Better than before

► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 60


Cluster POI MALEER

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 61


61
Cluster POI MALEER_Bad spot distribution

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 62


Cluster POI MALEER_BadSpot (COMPARISON BEFORE VS AFTER
► Analysis :
BEFORE AFTER Problem Found:
• Serving cell by
BSMMALEERMW1,BSMMALEERMW2,
GATOTSUBROTOMW3,JLCERMAIMW1
• Found high major alarm high temperatur
during drivetest on 10/09/2014 (OSS
KPI)
• HSPDSCHcodenum of JLCERMAIMW1
is "manual=1"
• high DL Power Congestion by
GATOTSUBROTOMW3 (current
CPICHPower is 346)
► Suggestion
• Modify HSPDSCHcodenum of JLCERMAIMW
from "manual=1" to "automatic,min=5,
max=10"
• Modify UPCPICHPower of
GATOTSUBROTOMW3 (decrease
CPICHPower from 346 to 343
► Action:
• Modify HSPDSCHcodenum of
JLCERMAIMW from "manual=1" to
"automatic,min=5, max=10"
• Modify UPCPICHPower of
GATOTSUBROTOMW3 (decrease
CPICHPower from 346 to 343
► DT Date : week 44
► Result : Better than before
► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 63


Cluster POI MALEER_Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 1944.12 Kbps 3392.75 Kbps
Maximum 9585.84 Kbps 9585.84 Kbps
Minimum 10.73 Kbps 234.28 Kbps
[0,56) 6 0
[56,128) 21 0
[128,256) 31 1
[256,512) 36 8
[512,1024) 12 21
[1024,2048) 18 31
[2048,14336) 68 122

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 64


Cluster POI UPI

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 65


65
Cluster POI UPI_Bad spot distribution

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 66


Cluster POI UPI
► Action:
Spot 1 :
BEFORE AFTER • Upgrade HSDPA Max user of HTLTLGSARIMW to 96
• Modify HSPDSCHCodeNum of HTLTLGSARIMW and
HTLTLGSARIMW from "manual=1" to "automatic,
min=5, max=10"
• Upgrade ULCE license of HTLTLGSARIMW
• Modify UCELLCAC of HTLTLGSARIMW (HSUPA Max
user 40, HSDPA Max user 96, UlNonCtrlThdForOther,
and modify UCELLHSUPA ( ErgchEhichCodeNum,
MaxTargetUlLoadFactor)
Spot 2 :
• Upgrade HSDPA Max user of HTLTLGSARIMW to 96
• Modify HSPDSCHCodeNum of LEDENGMX,
HTLTLGSARIMW, GERLONGGIRANGMW from
"manual=1" to "automatic, min=5, max=10"
• Upgrade ULCE license of HTLTLGSARIMW
• Modify UCELLCAC of HTLTLGSARIMW (HSUPA Max
user 40, HSDPA Max user 96, UlNonCtrlThdForOther,
and modify UCELLHSUPA ( ErgchEhichCodeNum,
MaxTargetUlLoadFactor)
Spot 3 :
• Upgrade HSDPA Max user of HTLTLGSARIMW to 96
• Modify HSPDSCHCodeNum of UPIBANDUNG2IW and
HTLTLGSARIMW from "manual=1" to "automatic,
min=5, max=10"
• Upgrade ULCE license of HTLTLGSARIMW
• Modify UCELLCAC of HTLTLGSARIMW (HSUPA Max
user 40, HSDPA Max user 96, UlNonCtrlThdForOther,
and modify UCELLHSUPA ( ErgchEhichCodeNum,
MaxTargetUlLoadFactor)
• physical tuning (Uptilt) cell ISOLAMW2 from Az155
M0E6 to Az155 M0E4

► DT Date : week 45
► Result : Better than before
► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 67


Cluster POI UPI - Analysis
► Analysis :
Problem Found:
Spot 1 :
• Low throughput by cell UPIBANDUNG2IW2 and HTLTLGSARIMW3
• High HS User and ULCE Congestion on cell HTLTLGSARIMW3, the current HSDPA Max User is 64
• HSPDSCHCodeNum current setting of cell UPIBANDUNG2IW2 and HTLTLGSARIMW3 is "manual=1",
• Missing neighbors from LEDENGMX2 to HOTELBANANAMX3
Spot 2 :
• Serving Celll from LEDENGMX3,HTLTLGSARIMW2,GERLONGGIRANGMX1
• High HS User and ULCE Congestion on cell HTLTLGSARIMW3, the current HSDPA Max User is 64
• HSPDSCHCodeNum HTLTLGSARIMW is "manual=1"
• HSPDSCHCodeNum site LEDENGMX3 is "manual=1“
Spot 3 :
• Low throughput by cell UPIBANDUNG2IW2 and HTLTLGSARIMW3
• High HS User and ULCE Congestion on cell HTLTLGSARIMW3, the current HSDPA Max User is 64
• HSPDSCHCodeNum current setting of cell UPIBANDUNG2IW2 and HTLTLGSARIMW3 is "manual=1",
• Missing neighbors from LEDENGMX2 to HOTELBANANAMX3
► Suggestion
Spot 1 :
• Modify HSPDSCHCodeNum site HTLTLGSARIMW From "manual=1" to "automatic, min=5, max=10"
• Audit neighbors relation
• Upgrade UCELLCAC of HTLTLGSARIMW (HSUPA Max user, HSDPA Max user, UlNonCtrlThdForOther) and modify UCELLHSUPA ( ErgchEhichCodeNum, MaxTargetUlLoadFactor)
• Upgrade ULCE License
Spot 2 :
• Modify HSPDSCHCodeNum site HTLTLGSARIMW From "manual=1" to "automatic, min=5, max=10"
• Modify HSPDSCHCodeNum site LEDENGMX3 From "manual=1" to "automatic, min=5, max=10"
• Upgrade UCELLCAC of HTLTLGSARIMW (HSUPA Max user, HSDPA Max user, UlNonCtrlThdForOther) and modify UCELLHSUPA ( ErgchEhichCodeNum, MaxTargetUlLoadFactor)
• Upgrade ULCE License
Spot 3 :
- Modify HSPDSCHCodeNum site HTLTLGSARIMW From "manual=1" to "automatic, min=5, max=10"
- Audit neighbors relation
- Upgrade ULCE License
- Upgrade UCELLCAC of HTLTLGSARIMW (HSUPA Max user, HSDPA Max user, UlNonCtrlThdForOther) and modify UCELLHSUPA ( ErgchEhichCodeNum, MaxTargetUlLoadFactor)

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 68


Cluster POI UPI_Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 1334.51 Kbps 1983.13 Kbps
Maximum 7299.84 Kbps 7299.84 Kbps
Minimum 122.82 Kbps 224.39 Kbps
[0,56) 0 0
[56,128) 1 0
[128,256) 6 1
[256,512) 26 3
[512,1024) 47 45
[1024,2048) 59 106
[2048,14336) 26 95

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 69


Cluster POI PASTEUR

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 70


70
Cluster POI PASTEUR_Bad spot distribution

Spot 1

Spot 2

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 71


Cluster POI PASTEUR_Spot 1
► Analysis :
Problem Found:
BEFORE AFTER • Serving cell from MARANATHAMW2,SUKAWARNAMW1
• MARANATHAMW2,SUKAWARNAMW1
• MARANATHAMW2,SUKAWARNAMW1 high hsdpa user
• MARANATHAMW2 HSPDSCHCodeNum already set
"automatic, min=5,max=10"
• HSPDSCHCodeNum cell SUKAWARNAMZ1 is
"manual=1"
► Suggestion
• Modify HSPDSCHCodeNum of serving cells to
"automatic,min=5,max=10"
► Action:
• Modify HSPDSCHCodeNum of serving cells to
"automatic,min=5,max=10"
► DT Date : week 44
► Result : Better than before
► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 72


Cluster POI PASTEUR_Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 1611.4 Kbps 2439.1 Kbps
Maximum 6679.69 Kbps 6679.69 Kbps
Minimum 1 Kbps 10.78Kbps
[0,56) 2 1
[56,128) 16 0
[128,256) 6 0
[256,512) 41 11
[512,1024) 73 23
[1024,2048) 106 75
[2048,14336) 89 160

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 73


Cluster POI PASTEUR_Spot 2
► Analysis :
Problem Found:
BEFORE AFTER • Serving cell
from_JUNJUNANMX2,BALADEWAMX3,MSJDHA
BB
• BALADEWAMW in good condition
• HSPDSCHCodeNum cell BALADEWAMW already
set "manual=5"
• HSPDSCHCodeNum cell JUNJUNANMW is
"manual=1"
• HSPDSCHCodeNum cell JUNJUNANMW and
MSJDHABB are "manual=1"
• Low throughput by JUNJUNANM and
MSJDHABBM
► Suggestion
• Modify HSPDSCHCodeNum of serving cells to
"automatic,min=5,max=10"
► Action:
• Modify HSPDSCHCodeNum of serving cells to
"automatic,min=5,max=10

► DT Date : week 44
► Result : Better than before
► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 74


Cluster POI PASTEUR_Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 1789.57 Kbps 2770.89 Kbps
Maximum 8476.91 Kbps 8476.91 Kbps
Minimum 0.96 Kbps 253.58 Kbps
[0,56) 8 0
[56,128) 17 0
[128,256) 20 1
[256,512) 51 5
[512,1024) 30 12
[1024,2048) 60 41
[2048,14336) 82 72

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 75


Cluster POI SARIJADI CLUSTER

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 76


76
Cluster POI SARIJADI CLUSTER_Bad spot distribution

Spot 1

Spot 2

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 77


Cluster POI SARIJADI CLUSTER _Spot 1
► Analysis :
Problem Found:
BEFORE AFTER • Serving cell from_BUKITINDAHMW
• HSPDSCHCodeNum cell BUKITINDAHMW is
"manual=1"
• Low throughput due to UE RRC State is FACH
► Suggestion
• Modify HSPDSCHCodeNum BUKITINDAHMW
From “manual=1” to "automatic,min=5,max=10
► Action:
• Modify HSPDSCHCodeNum BUKITINDAHMW
From “manual=1” to "automatic,min=5,max=10

► DT Date : week 44
► Result : Better than before
► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 78


Cluster POI SARIJADI CLUSTER_Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 3737.91 Kbps 4275.03 Kbps
Maximum 9091.2 Kbps 9091.2Kbps
Minimum 0.1 Kbps 10.03 Kbps
[0,56) 37 2
[56,128) 0 0
[128,256) 0 0
[256,512) 0 0
[512,1024) 1 3
[1024,2048) 30 27
[2048,14336) 196 245

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 79


Cluster POI SARIJADI CLUSTER _Spot 2
► Analysis :
Problem Found:
BEFORE AFTER • Serving cell by SARIJADIMW
• SARIJADIMW down since 14 October 2014, have
plan dismentle from customer and will be replace
with combat site
• There are congestion (Power,User) SARIJADIMW
• overshoot by GEGERKALONGMW2
► Suggestion
• - Modify HSPDSCHCodeNum SARIJADIMW From
"manual=1" to "automatic, min=5, max=10"
• - Down tilt cell GEGERKALONGMW2 to reduce
overshoot
► Action:
• Modify HSPDSCHCodeNum of SARIJADIMW
From "manual=1" to "automatic, min=5, max=10"
• Down tilt cell GEGERKALONGMW2 Az120 M5E3
to Az120 M5E5
► DT Date : week 44
► Result : Better than before
► Status : Closed

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 80


Cluster POI SARIJADI CLUSTER_Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 1846.95 Kbps 2067 Kbps
Maximum 7321.95 Kbps 7357.22 Kbps
Minimum 0.13 Kbps 138.17 Kbps
[0,56) 9 0
[56,128) 6 0
[128,256) 7 5
[256,512) 41 15
[512,1024) 58 46
[1024,2048) 102 5
[2048,14336) 120 136

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 81


Cluster POI SARIJADI ROAD

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 82


82
Cluster POI SARIJADI Road_Bad spot distribution

Spot 1

Spot 2

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 83


Cluster POI SARIJADI Road _Spot 2
► Analysis :
Problem Found:
BEFORE AFTER • Serving cell by
MARANATHAMX3,SARIJADI117MX1
• Bad Quality due to pollutant
• current seting HSPDSCHCodeNum
SARIJADI117MW is "manual=1"
• SARIJADIMW down, have plan dismentle from
customer and will be replace with combat site
► Suggestion
• Phsycal tuning site MARANATHAMW and
GEGERKALONGMMW2 to make dominant server
• Modify HSPDSCHCodeNumof SARIJADI117MW From
"manual=1" to "automatic, min=5, max=10"
► Action:
• Modify HSPDSCHCodeNumof SARIJADI117MW From
"manual=1" to "automatic, min=5, max=10“

► DT Date : week 44
► Result : Better than before
► Status :

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 84


Cluster POI SARIJADI Road_Statistic

TELKOMSEL Before TELKOMSEL After


Element RLC SDU Throughput DL_All Logs
Average 1311.19 Kbps 1444.85 Kbps
Maximum 7845.06 Kbps 7845.06 Kbps
Minimum 84.44 Kbps 73.64Kbps
[0,56) 0 0
[56,128) 4 2
[128,256) 21 2
[256,512) 32 8
[512,1024) 85 103
[1024,2048) 80 83
[2048,14336) 36 41

[14336,58000] 0 0

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential 85


Thank you
www.huawei.com

Copyright©2011 Huawei Technologies Co., Ltd. All Rights Reserved.


The information in this document may contain predictive statements including, without limitation, statements
regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number
of factors that could cause actual results and developments to differ materially from those expressed or implied in the
predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an
offer nor an acceptance. Huawei may change the information at any time without notice.

You might also like