Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 13

Process Redress Of SCSSV For Reuse

@NJG-A Yard

Location : NJG-A Yard


Date : 23 April 2020
Participations
1. Seksan J. Senior Technician, Workshop, OTN
2. Kitsada K. Technician, KIS
3. Somkait S. Technician, KIS
4. Thitinan T. Technician, KIS
5. Jaruthat M. Technician, KIS
6. Workshop Sub-Assembly Team.
Working Process Redress Of SCSSV For Reuse
1. Visual Check SCSSV Body and thread _OK
2. Cleaning SCSSV Body and thread _OK
3. Disassembly SCSSV for cleaning _OK
3.1 Borescope Inspection _OK
4. Visual Check all parts of SCSSV( O-Ring Size. 3.0mm. Thk. x 76.00mm. ID )_OK
5. Assemble and install material parts list SCSSV_OK
5.1 Dimension Check1430 mm_OK
6. FUNCTION TESTING SCSSV_OK
6.1 Open-Close _OK
6.2 Check Hydraulic Return _OK
7. P/T Body SCSSV( Open ) and ( Close ) SCSSV inflow Test( 3,000psi )_OK
8. Interior Drift 2.8 inch and Set plug to x-profile and P/T( 3,000psi )_OK
9. FUNCTION TESTING SCSSV DATA SHEET RECORD_OK
1. Visual Check SCSSV Body and thread_OK.
2. Cleaning SCSSV Body and thread_OK.
3. Disassembly SCSSV for cleaning _OK
3.1 Borescope Inspection _OK
4. Visual Check all parts of SCSSV( O-Ring Size. 3.0mm. Thk. x 76.00mm. ID )_OK
5. Assemble and install material parts list SCSSV_OK
5.1 Dimension Check 1430 mm _OK

1430 mm.
6. FUNCTION TESTING SCSSV_OK
6.1 Open-Close _OK
6.2 Check Hydraulic Return _OK
7. P/T Body SCSSV( Open ) and ( Close ) SCSSV inflow Test( 3,000psi )_OK
8. Interior Drift 2.8 Inch and Set plug 2.813 Inch to x-profile and P/T( 3,000psi )_OK
8. Set plug 2.813 Inch to x-profile and P/T( 3,000psi )_OK
9. FUNCTION TESTING SCSSV DATA SHEET RECORD_OK
End of Report