Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 27

TJ8300 / TJ8500

Engineer Training

Electrical Cabinet (EC)

Electrical Cabinet (EC)


TJ8300 / TJ8500
General Description
Engineer Training

 The electrical cabinet is located inside the electronics cabinet.


 The electrical cabinet (structure) is comprised of the base and
the panel door.
 It receives the main power supply line from the machine –
3X230VAC + Natural + GND – (max.) total of 63A (per phase).
 The electrical cabinet is responsible for the following functions:
 PDU – power distribution to all components in the machine
 Operation of drum heating
 Operations of pumps (vacuum and evacuation)
 Protections (overheat and under speed)
Confidential Electrical Cabinet (EC) 2
TJ8300 / TJ8500
Structure
Engineer Training

Panel

Base

Confidential Electrical Cabinet (EC) 3


TJ8300 / TJ8500
Inputs
Engineer Training

Power and auxiliary inputs are located at the bottom of the


Electrical cabinet.

Input of main power line Input of UPS Auxiliary


3x230VAC+N+GND outputs
63A Max (per phase)

Confidential Electrical Cabinet (EC) 4


TJ8300 / TJ8500
Power Distribution
Engineer Training

CN1

Stabilizer and protection from spikes


lightning T1-12VAC Transformer for
Main contactor 63A emergency switches
and noise reducer (up to 20DB)

Confidential Electrical Cabinet (EC) 5


TJ8300 / TJ8500
Power Distribution (Cont.)
Engineer Training

S2-Earth leakage current breaker S3-UPS breaker

S1-Main circuit breaker (4 pole) S5-Drum heating breaker

Confidential Electrical Cabinet (EC) 6


TJ8300 / TJ8500
Power Distribution (Cont.)
Engineer Training

Up to machine 74

OL1 - OL2 - Hot air OL3 -


CN5 -
CN6 - HA CN7 - Vacuum fans Evacuation
Vacuum
fan Evacuation blower overload blower overload
blower
contactor blower overload relay relay
contactor
contactor relay (up to 1.6A) (up to 1.6A)
(up to 6.3A)

Confidential Electrical Cabinet (EC) 7


TJ8300 / TJ8500
Power Distribution (Cont.)
Engineer Training

From machine 75

CN5 - CN6 - HA OL1- OL2 - Hot


Vacuum fan Vacuum air fans
blower contactor blower overload
contactor overload relay (up to
relay (up to 1.6A)
6.3A)

Confidential Electrical Cabinet (EC) 8


TJ8300 / TJ8500
Power Distribution (Cont.)
Engineer Training

Up to machine 74

PH1 – Phase relay.


Green and orange light
indicate the right phase order.
If the phase order is wrong,
the pumps will not work.

Confidential Electrical Cabinet (EC) 9


TJ8300 / TJ8500
Power Distribution (Cont.)
Engineer Training

S8-Breaker of Auxiliary 1 (J15).


S9-Breaker of Auxiliary 2 (J14).
S6-Breaker of Supply unit,
computer and peripherals. S11-Output power to J11
S12-output power to J12
S7-Transformer Breaker.

Confidential Electrical Cabinet (EC) 10


TJ8300 / TJ8500
Electrical Cabinet Panel
Engineer Training

The panel includes:

 Drum heat controller board


 Receives the requested temperature from the computer and
heats the drum with a combination of IR and hot air fans.
 Receives feedback of the real drum temperature measured
by the IR sensors.

 Controls for two under speed protection


(Tahco generator and under speed sensor).

Confidential Electrical Cabinet (EC) 11


TJ8300 / TJ8500
Electrical Cabinet Panel (Cont.)
Engineer Training

 Controls for two separate overheat protections


 Temperature readings from two IR sensors under the drum
are compared to the preset value in two separate voltage
relays.
 If the potentiometer on the voltage relay is set to 1, the
overheat message appears when the relevant IR sensor
reads more then 100ºC.

 Dryer enable
 HA fans and IR controls, control operations of all pumps.

Confidential Electrical Cabinet (EC) 12


TJ8300 / TJ8500
Door Panel (Cont.)
Engineer Training

Confidential Electrical Cabinet (EC) 13


TJ8300 / TJ8500
Door Panel
Engineer Training

 Voltage relay I – sets the


potentiometer to 1 (max)
displays the overheat 1
message at 100ºC .

 Voltage relay II – sets the


potentiometer to 1 (max)
displays the overheat 1
message at 100ºC.

 Normally, both units are set to 0.8, which means that the
overheat is set to 80ºC.

Confidential Electrical Cabinet (EC) 14


TJ8300 / TJ8500 Controller Board
Engineer Training (Drum Heat Controller)

Confidential Electrical Cabinet (EC) 15


TJ8300 / TJ8500 Controller Board
Engineer Training (Drum Heat Controller) – Cont.

CN3-IR heaters
CN2-UPS contactor contactor

Confidential Electrical Cabinet (EC) 16


TJ8300 / TJ8500 Controller Board
Engineer Training (Drum Heat Controller) – Cont.

F7, F8-IR heaters fuses (50A)

Confidential Electrical Cabinet (EC) 17


TJ8300 / TJ8500 Controller Board
Engineer Training (Drum Heat Controller) – Cont.

U3-24VDC Supply unit for the heating controller

Confidential Electrical Cabinet (EC) 18


TJ8300 / TJ8500 Controller Board
Engineer Training (Drum Heat Controller) – Cont.

Fuses for lamps and controls S15-Heat control breaker

S13-Breaker of IR units

Confidential Electrical Cabinet (EC) 19


TJ8300 / TJ8500 Controller Board
Engineer Training (Drum Heat Controller) – Cont.

1 – Solid state relay (SSR) unit for IR I heater control

2 – Solid state relay (SSR) unit for IR II heater control

Confidential Electrical Cabinet (EC) 20


TJ8300 / TJ8500
Indication Lights
Engineer Training

 L1, L2, L3 – indicates power phases input.

 UPS – Indicates UPS power input


(external source for computers only).

 ON – Lights up after machine initiates


(like in the traffic light indicator).

 VAC – Indicates when the vacuum pump is working.

Confidential Electrical Cabinet (EC) 21


TJ8300 / TJ8500
Indication Lights (Cont.)
Engineer Training

 HA – Indicates when the HA fans are working.

 EV - Indicates when the evacuation pump is working.

 EM SWITCH – Lights up as long as the emergency switches are


not pressed.

 MAIN/UPS switch selector – Manually switches between UPS


and Main Power.

Confidential Electrical Cabinet (EC) 22


TJ8300 / TJ8500
Indication Lights (Cont.)
Engineer Training

Confidential Electrical Cabinet (EC) 23


TJ8300 / TJ8500
Panel Door Indication Lights
Engineer Training

 OV1 – first protection for Over heat


(Reading temp’ from first IR sensor)

 OV2 – second protection for Over heat


(Reading temp’ from second IR sensor)

 Tacho speed – first protection for drum under speed from the
Tahco generator on the drum motor

Confidential Electrical Cabinet (EC) 24


TJ8300 / TJ8500
Panel Door Indication Lights (Cont.)
Engineer Training

 PROX speed – second protection for drum under speed,


monitoring the drum movement by the under speed sensor

 24VDC, 24VAC – indicates lights of controls

 Enable – dryer enabled signal

Confidential Electrical Cabinet (EC) 25


TJ8300 / TJ8500
Panel Door Indication Lights (Cont.)
Engineer Training

 HA control indication light

 IR control indication light

Confidential Electrical Cabinet (EC) 26


TJ8300 / TJ8500 Electrical Cabinet Components
Engineer Training

Confidential Electrical Cabinet (EC) 27