Configuration Guide
-- U2000 Web LCT
www.huawei.com
Configuration Tasks
Setting the
Hybrid/AM
attributes of the
XPIC Hybrid radio
link
Method 1:
Create an NE by
using the search
method.
①
②
④
Modify the NE ID.
The ID of an NE in
the network must
⑥ be unique.
⑤
③
If an ODU supports only one T/R spacing, set this parameter to the default value 0. The default transmission status of an
ODU is Unmute.
Set ATPC parameters according to the network planning documents. Note that before the antenna alignment, ATPC
Enabled must be set to Disabled.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Configuring the
Configuring Configuring the
Setting the Hybrid/AM an NE RF link mode
IF/ODU Information
of a Radio Link
Set AM Enable Status according to the network planning documents. Note that before the antenna alignment, make sure that AM
Enable Status is set to Disabled.
When AM Enable Status is set to Enabled, set Modulation Mode of the Guaranteed AM Capacity and Modulation
Mode of the Full AM Capacity according to the network planning documents.
E1 Capacity specifies the number of E1 services that can be transmitted in Hybrid microwave frames. Set this parameter according to
the design. Note that the number of E1 services at both ends of a radio link hop must be the same; otherwise, the services are
unavailable.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Configuring the
Creating an N+1 Configuring
an NE
Configuring the
RF link mode
IF/ODU Information
of a Radio Link
Protection Group
①
① ④
Use the
default Select a working IF board and a protection
value.
IF board. In the case of 1+1 FD/SD
protection group, the working board and
protection boards must be configured in
two paired slots.
Configuring the
IF/ODU Information
an NE RF radio link
of a Radio Link
①
④
Set the source slot, source port, source VC4, and source
timeslot of the working source and protection source. The
working service source and protection service source can be the
IF board or the line board. However, the IF 1+! protection board
cannot be used as the source of SNCP services.
Set the sink slot, sink port, sink VC4, and sink timeslot of the
SNCP service sink. If Sink is set to the slot of the tributary board,
Sink Port and Sink VC4 are unavailable.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Contents
1. Service Types of the OptiX RTN
900 V100R002
1 Setting the Setting the Setting the Setting the Setting the
parameters of parameters of parameters of parameters of parameters of
Ethernet ports Ethernet ports Ethernet ports Ethernet ports Ethernet ports
2 Setting the Setting the Setting the Setting the Setting the
parameters of parameters of parameters of parameters of the parameters of the
the IF_ETH the IF_ETH the IF_ETH IF_ETH ports IF_ETH ports
ports ports ports
Note:
① indicates that the configuration item is optional. Configure the services according to the service
requirements.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Configurations of Ethernet Services
Setting the Parameters of Ethernet Ports
Setting the Parameters of IF_ETH Ports
Configuring the LAG
Configuring the QinQ Link
Configuring the E-Line Service
Configuring the ERPS
Configuring the E-LAN Service
Configuring the QoS
Verifying Ethernet Service Configurations
VLAN-based E-Line
services: Setting Setting the Setting the
Configuring the layer 2 advanced
QinQ-based E-Line general
traffic control attributes attributes
attributes
services:
③ Ports on an
IF_ETH ports
④ Ethernet board
In the case of used ports, set Enable Port to Enabled. In the case of unused ports, set Enable Port to Disabled.
Encapsulation Type
In the case of P2P E-Line services and IEEE 802.1d bridge-based E-LAN services, set Encapsulation Type to Null.
In the case of VLAN-based E-Line services and IEEE 802.1d bridge-based E-LAN services, set Encapsulation Type to
802.1q.
In the case of QinQ-based E-Line services and IEEE 802.1ad bridge-based E-LAN services, if a UNI can access untagged
frames, set Encapsulation Type to NULL. If a UNI can access tagged frames only, set Encapsulation Type to 802.1q. In
the case of an NNI port, set Encapsulation Type to QinQ.
In the case of an Ethernet port that is connected to the external equipment, set Working Mode to a value the same as that of
the external equipment. (Generally, Working Mode of the external equipment is set to Auto-Negotiation. In the case of the
Ethernet ports within the network, set Working Mode to Auto-Negotiation.
When JUMBO frames are transmitted, set Max Frame Length (byte) according to the actual length of the JUMBO frames.
Otherwise, it is recommended that you set Max Frame Length (byte) to 1536.
After the traffic control is enabled, if the link is congested, the Ethernet port sends the PAUSE frame to
notify the peer end of stopping the transmission of Ethernet packets for a period, thus eliminating the
link congestion.
Required when the flow control function is enabled on the external equipment to which the Ethernet
port is connected. Set the parameters as follows:
When the external equipment uses the non-auto-negotiation flow control function, set Non-
Autonegotiation Flow Control Mode to Enable Symmetric Flow Control.
When the external equipment uses the auto-negotiation flow control function, set Auto-
Negotiation Flow Control Mode to Enable Symmetric Flow Control.
For P2P E-Line services and IEEE 802.1d bridge-based E-LAN services: You do not need to set the layer 2 attributes.
For VLAN-based E-Line services and IEEE 802.1 bridge-based E-LAN services: If all the accessed services carry VLAN
tags (tagged frames), set Tag to Tag Aware. If none of the accessed services carries VLAN tags (untagged frames), set
Tag to Access. If the access services contain both tagged frames and untagged frames, set Tag to Hybrid. Set Default
VLAN ID and VLAN Priority according to the network planning information.
For QinQ-based E-Line services and IEEE 802.1ad bridge-based E-LAN services: In the case of a UNI port, if
Encapsulation Type is set to 802.1q, Tag must be set to Tag Aware (default value). In the case of an NNI port that is
connected to the external equipment, set QinQ Type Domain according to the T-PID of the SVLAN that is supported by
the external equipment. In the case of an NNI port within the network, set QinQ Type Domain to the default value.
The advanced attributes of Ethernet ports are used to configure the MAC/PHY loopback and query the traffic rate on
the ports.
Required when you need to enable the port self-loop test and automatic loopback shutdown functions or to enable the
broadcast packet suppression function. Set Loopback Check, Loopback Port Shutdown, Enabling Broadcast Packet
Suppression, and Broadcast Packet Suppression Threshold according to the requirements.
①
⑤
Encapsulation Type
In the case of P2P E-Line services and IEEE 802.1d bridge-based E-LAN services, set
Encapsulation Type to Null.
② In the case of VLAN-based E-Line services and IEEE 802.1d bridge-based E-LAN services,
set Encapsulation Type to 802.1q
In the case of QinQ-based E-Line services and IEEE 802.1ad bridge-based E-LAN
services, if a UNI can access untagged frames, set Encapsulation Type to NULL. If a UNI
can access tagged frames only, set Encapsulation Type to 802.1q. In the case of an NNI
③
④ port, set Encapsulation Type to QinQ
For P2P E-Line services and IEEE 802.1d bridge-based E-LAN services: You do not need to set the
layer 2 attributes.
For VLAN-based E-Line services and IEEE 802.1 bridge-based E-LAN services: If all the accessed
services carry VLAN tags (tagged frames), set Tag to Tag Aware. If none of the accessed services
carries VLAN tags (untagged frames), set Tag to Access. If the access services contain both tagged
frames and untagged frames, set Tag to Hybrid. Set Default VLAN ID and VLAN Priority according to
the network planning information.
For QinQ-based E-Line services and IEEE 802.1ad bridge-based E-LAN services: In the case of a UNI
port, if Encapsulation Type is set to 802.1q, Tag must be set to Tag Aware (default value). In the case
of an NNI port that is connected to the external equipment, set QinQ Type Domain according to the T-
PID of the SVLAN that is supported by the external equipment. In the case of an NNI port within the
network, set QinQ Type Domain to the default value.
When the IF_ETH port transmits an Ethernet service that permits bit errors, such as a voice service
or a video service, you can set Error Frame Discard to Disabled.
① ⑤
③ ⑥
④
Set LAG Type to the same value as the opposite equipment. Generally,
set LAG Type to Static for the equipment at both ends.
In the case of FE/GE ports, set Load Sharing to the same value as the
opposite equipment. If the LAG is configured only to realize protection, it
is commended that you set Load Sharing to Non-Sharing for the
equipment at both ends. If the LAG is configured to increase the
bandwidth, it is recommended that you set Load Sharing to Sharing for
the equipment at both ends. When the Hybrid microwave uses the
N+0/XPIC configuration mode, set Load Sharing to Sharing for the
equipment at both ends.
Set Revertive Mode to the same value as the opposite equipment.
Generally, set Revertive Mode to Revertive for the equipment at both
ends. This parameter is valid to only LAGs whose
Set Load Sharing to Non-Sharing. Set System Priority to the default
value. This parameter is valid to only static LAGs.
Set Main Board, Main Port, and Selected Slave Ports according to
the planning information. It is recommended that you set this parameter to
the same value for the main and slave ports of the LAGs at both ends. The
Hybrid/AM attributes of the IF ports in the LAGs must be the same.
Port Priority indicates the priorities of the ports in a LAG as defined in the LACP
protocol. The smaller the value, the higher the priority. When ports are added into a
LAG, the port of the highest priority is preferred for service transmission.
Set System Load Sharing Hash Algorithm to the same value as that of the opposite
equipment. Unless otherwise specified, this parameter takes the default value. This
parameter is valid to only LAGs whose “Load Sharing” is set to Sharing. The load sharing
computation methods include:MAC address specific allocation (based on the source MAC
address, destination MAC address, and XOR between source MAC address and source
MAC address), IP address specific allocation (based on the source IP address, destination
IP address, and XOR between source IP address and destination IP address).
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Configurations of Ethernet Services
Setting the Parameters of Ethernet Ports
Setting the Parameters of IF_ETH Ports
Configuring the LAG
Configuring the QinQ Link
Configuring the E-Line Service
Configuring the ERPS
Configuring the E-LAN Service
Configuring the QoS
Verifying Ethernet Service Configurations
③ ⑤
④
⑤
②
③
④
② ④
③
③
④
Configured
ports
Click Next.
The OptiX RTN 900 has a default DS domain, for which Mapping Relation ID is set to 1 and
Mapping Relation Name is set to Default Map. Before another DS domain is created, all the ports
belong to this default DS domain. The default DS domain cannot be modified or deleted.
④
②
③
④
Select a mapping relation to be changed.
⑥
②
③
②
③
④
Configure the queue scheduling, policy weight, and queue shaping of the port queue.
Grooming Police After Reloading: Set the strict priority (SP) scheduling algorithm
according to the planning information. Note that except for the default value, the value of the
WRR scheduling algorithm and the value of the SP scheduling algorithm cannot be interleaved.
That is, except for the default value, Grooming Police After Reloading can be changed from
SP to WRR according to the queue priorities in a descending order (CS7-BE).
Policy Weight: specifies the weight of the policy in the WRR queue. The weight indicates
the percentage of the bandwidth resources obtained by the WRR queue.
Bandwidth Limit: indicates or specifies whether the traffic shaping function is enabled for
the PHB service class queues in the egress direction. CIR, PIR, CBS, PBS can be set only
when Bandwidth Limit is set to Enabled.
②
③
⑤
②
③
⑤
②
③
Select a port to be used
in Available Port.
③ ④
⑦
③
④
This task is required in the case that the NEs where the two Ethernet interfaces involved in the
service test are located. Set the main parameters as follows:
The MD names and levels of different NEs must be the same.
In the test of Ethernet services between two edge nodes on the transport network, it is
recommended that you set Maintenance Domain Level to 4. In the test of Ethernet services
between two NEs within the transport network, set Maintenance Domain Level to a value
less than 4. In the test of Ethernet services between two Ethernet ports on the same NE, set
Maintenance Domain Level to a value less than that set in the test of Ethernet services
between two NEs within the transport network.
⑦
③
④
⑥
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Creating Testing
Creating Creating Creating an Ethernet
remote MEPs
an MD an MA MEP point services
in an MA
③ ⑦
④
Set Maintenance Association Name to the value of Maintenance Association Name that is
set in the preceding step.
Set Board and Port to the Ethernet ports involved in the service test.
Set MP ID to different values for MEPs in the same MD.
In this example, Ethernet services between two internal NEs on the transport network are tested.
Hence, set Direction to Ingress for the MEPs.
The MP ID is used to identify the MEP during the LB test. Hence, set CC Status to Active.
③ ⑦
④
Set Maintenance Domain Name to the value of Maintenance Domain Name that is set in the
preceding step.
Set Maintenance Association Name to the value of Maintenance Association Name that is set
in the preceding step.
If other MEPs may initiate OAM operations to an MEP in the same MA, set the other MEPs to be
the remote MEPs.
⑦
③
④
Source Destination
maintenance point maintenance point
in the LB test in the LB test
Transmitted Packet Count: specifies the number of packets transmitted each time in the LB test. The
duration gets longer with the increase of numbers.
Transmitted Packet Length: specifies the length of a transmitted LBM packet. If the packet length is
different, the test result may be different. In normal cases, it is recommended that you use the default value.
Transmitted Packet Priority: specifies the priority of transmitted packets. 0 indicates the lowest priority,
and 7 indicates the highest priority. In normal cases, it is recommended that you set this parameter to the
highest priority.
Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.
Creating Testing
Creating Creating Creating an Ethernet
remote MEPs
an MD an MA MEP point services
in an MA