SEISMIC ANALYSIS OF TALL

STRUCTURES BY CONCRETE
DIAGRID SYSTEM USING
RESPONSE SPECTRUM
METHOD
Guide: Dr. Y.Himath Kumar

Department of Civil Engineering


OBJECTIVE
 To analyse and design the concrete diagrid structures using ETabs.

 To analyse the seismic performance behaviour of concrete diagrid structure.

 To analyse and design the concrete diagrid structure compare with brace frame tube structure

with the help Etabs software.


DIAGRID STRUCTURES:
Diagrid is an exterior structural system in which all perimeter vertical columns are eliminated
and consists of only inclined columns on the façade of the building. Shear and over-turning
moment developed are resisted by axial action of these diagonals compared to bending of
vertical columns in framed tube structure.

BRACE FRAME TUBE STRUCTURES:


A braced frame is a structural system designed to resist wind and earthquake forces. Members in

a braced frame are not allowed to sway laterally.


LITERATURE REVIEW

Author & Year Paper Title Objective Methodology Outcome Research Gap
It is concluded that
steel diagrid
Seismic seismic To evaluate the
structures had
performance performance of 36- effect of diagrid
larger initial
assessment of story diagrid core
Mahdi stiffness compared This paper doesn’t
tubular diagrid structures with on behavior of
Heshmatia,Alireza to CBFs and MRFs, show any shear lag
structures with varying angles are structures. Interior
Khatamia (2020) and ductility of phenomenon
varying evaluated using gravity frames are
diagrids could be an
angles in tall steel push over and non- replaced with
issue for diagrids in
buildings linear static analysis diagrid frames.
high seismic
regions.
The distribution of the
plastic
The seismic
Improving the seismic To improving the behavior of the
performance of This paper doesn’t
performance of diagrid seismic performance diagonals becomes
Saman Sadeghi,Fayaz diagrids equipped with show non-linear static
structures using of diagrid structures more uniform
R. Rofooei (2019) buckling restrained and dynamic analyses
buckling restrained through application of throughout the
braces (BRBs) is on diagrid model.
braces BRBs is proposed. structure
investigated.
when partially
equipped with BRBs.
To concluded that for
The diagrid structure different diagrid
To analyze the story This paper shows that
is designed, analyzed systems using ETABS
Analysis on the drift,displacement,max when compared
and is compared with software to find the
diagrid structure with imum bending and diagrid structures with
Neha Tirkey, G.B. the conventional stiffness and flexibility
the conventional shear force for the conventional
Ramesh Kumar (2019) building using ETABS of the high raised
building frame using diagrid buildings of structures it have must
software mainly structures and also for
ETABS rectangualr,I section less failure during
focusing on wind and an asymmetrical
and l sections shapes. earthquake.
earthquake parameters structure through
simple framework
It is concluded that the
The seismic pin and rigid types of
This paper shows the
performance of diagrid To improve the end-connection of
gap between axial
Quantification of the structures with seismic behaviour of diagrid perimeter
performance of
Saman Sadeghi, Fayaz seismic performance different no of floors diagrid structure beams was found to
diagrids and post yield
R. Rofooei (2018) factors for steel and various diagonal replace the rigid ended have no effects on
behaviour of end
diagrid structures angles are designed beam by pinned ended stiffness of the diagrid
connection of
using different r- beams. models.For diagrid the
perimeter beams
factors angles is 45,63.4 and
71.5.
To analyze the 60
The structure is This paper shown
story building
analysed statically the efficient results
model interstory
and dynamically of geometrical
Dynamic analysis height 3.2m and
The study is made both for seismic diagrid patteren of
of diagrid studied the
Akshat, Gurpreet on the basis of loads. This structure different angles of
structural system equivalent static
Singh (2018) lateral load due to analyzed the 67.38 and 71.56
in high rise method is used for
earthquake showing results degrees but it
buildings finding the response
story drift, story doesn’t shown the
of structures against
displacement and accurate angles like
the earthquake
story shear. 45, 63.4 degree
loads.

To analysis of 36,
To this aim 48, 60 storey The diagrid This paper shown
Response of High response of four diagrid structure structure is showing the results of by
Snehal S. Mali,D. Rise Building with different diagrid and then better solution for equivalent static
M. Joshi (2017) Different Diagrid structures of (G+30) comparison of these lateral load resisting method but doent
Structural System storey are carried buildings with system interms of shown response
out to obtain conventional lateral displacement spectrum method
optimized position structure.
of diagrid.