Patanjali SMU2430 Operating Rescrch
4. Fault Indication
1. Menu Switch
3. PV Charging Indication
2. Set Switch
5. Battery
6. Solar Connection
Connection
500W-12V Battery
12V or 24V
1000W-24V Battery
Battery
Function Description
1. Menu Switch :- Menu switch is used to change the basic setting of Boost Voltage, Float
Voltage, Mains Reconnect setting, Energy Saver Mode and for resetting the energy
counter.
2. Set Switch :- Set switch is used to change the parameter setting of Boost Voltage, Float
Voltage, Mains Reconnect Setting and energy saver Mode.
3. PV Charging Indication:- This indication shows the battery charge status i.e. Battery
full charge or charging under process.
4. Fault Indication:- This indication shows the various faults like low battery, battery over
voltage, solar reverse current.
5. Battery Connection:- This connector is used for battery connection. Battery voltage
(12V or 24V) auto sensing.
6. Solar Connection:- This connector is used for solar connection. For Battery voltage 12V
500W solar panel and for 24V battery 1000W Solar Panel is recommended.
Technical Specification
Efficiency >96%
Grid disconnect from Inverter After Battery goes to Float Charge mode and PV Energy available