CMTD
Objectives (upon completion operator should be able to)
Understand basic theory of operation of CMTD
Know the different CMTD Types and when they are used
Practical Tasks
Schlumberger Private
Perform Preventive maintenance
Use manual drawings to find parts and determine correct roller diameter
Measure CMTD roller diameter and check for acceptable tolerance
Equipment
CMTD, Basic Tools, Laminated Drawing, BOM, Micrometer / Caliper
References
CMTD Maintenance Manual (ID: 3012541)
GlobalTops-V1 (ID: 4033414)
WL-Training-
GlobalTOPS_V1.1_Oct 2011
Safety
• Complete Personnel Protection Equipment (PPE)
• Logging Unit should be moved ONLY after CMTD is Stowed for Transport
Schlumberger Private
• Pinch points while installing
• If in doubt, ASK
WL-Training-GlobalTOPS_V1.1_Oct 2011
CMTD
Schlumberger Private
Follow the SAFE WINCH OPERATIONS Placard at all times (ID: 3885138)
WL-Training-GlobalTOPS_V1.1_Oct 2011
CMTD
Description
The Cable Mounted Tension Device is a tension device to measure load on running cable
Schlumberger Private
WL-Training-GlobalTOPS_V1.1_Oct 2011
CMTD
Theory of Measurement
CMTD uses a strain axle to determine tension. (ID: 3012541)
Using the correct CMTD rollers (with wear within tolerance) is critical to maintain the angle the
cable makes against the strain axle.
Applied load on
strain axle is
Schlumberger Private
converted to
signal equivalent
to tension
Load on Axle
Cable bending
applies load on strain
axle
WL-Training-
GlobalTOPS_V1.1_Oct 2011
CMTD
H353160 (Ceramic) can be substituted with
H701074 (dimensions are the same)
Schlumberger Private
H701076 H701063 3.000
WL-Training-GlobalTOPS_V1.1_Oct 2011
CMTD
Nominal strain axle measurement for M.D Totco strain Nominal strain axle measurement for Interface strain
axles axles
Connector Pins Resistance Range Connector Pins Resistance Range
(ohms) (ohms)
From A-B 268-335 From A-B 268-335
Schlumberger Private
From D-A 268-335
From D-A 268-335
From A-C (excitation circuit) 370-510
From A-C (excitation circuit) 370-510
From B-D (Signal Circuit) 345-355
From B-D (Signal Circuit) 285-295
Schlumberger Private
Calibration for Tension Device Calibrator Yearly
(IT # 4862290): Always use the load cell and digital display together as
set, as they were calibrated. Otherwise the calibration performed
with different set of load cell and digital display will be wrong.
WL-Training-
GlobalTOPS_V1.1_Oct 2011
Maintenance - CMTD Maintenance Manual (ID: 3012541)
FIT TRIM Q Check
Before and after every job Every month Every year
Check resistance values of strain
axle before TRIM.
Inject standard automotive axle Measure the diameter of all Measure the strain axle pin-to-
Schlumberger Private
grease into all CMTD grease the CMTD rollers for wear pin resistance values and
fittings compare with the nominal values
Check that all the guide rollers Check insulation and continuity Disassemble the CMTD and
roll freely of the complete check the groove diameter of all
instrumentation cable to be used rollers
Clean the CMTD thoroughly Perform a Shop Calibration Replace those parts that have
after each job unacceptable
wear or damage.
WL-Training-