Building Services - III

A.DEVAROSHAN
WINDOW AC

 Size :
 Size for 0.75 ton - Indoor 60 cm x 38 cm x 56 cm
 Size for 1 ton – Indoor -75.5 x 66 x 43 cm
 Size for 1.5 ton - Indoor - 66cm x 70.5cm x 43cm.
 Indoor Unit Weight 35.1 kg
 Tonnage limited is 0.5 to 2 ton used in maximum 25
Sq.m.
 It is mainly used , Home , Shops , Small spaces.
PACKAGED AC
 These units are used commonly in
places like restaurants, telephone
exchanges, homes, small halls.
 The packaged air conditioners are
available in the fixed rated
capacities of 3, 5, 7, 10 and 15
tons.
 Standard dimensions - Outdoor Unit
Dimensions: 1020x420x950 mm For
5 ton
SPLIT AC
 Size and weight of unit for 1 ton
 Dimension of outdoor unit is 78 x 54 x 25 cm
 Dimension of indoor unit is 79 x 26.5 x 19.5 cm
 Weight of the indoor unit is 9 kilograms
 Outdoor unit is 35 kilograms
 Size and weight of unit for 2 ton
 Indoor unit 32 × 99.8× 23.8 cm And 13 kg
 Outdoor unit 65× 82 × 32 cm and 55 kg weight.
 The Tonnage limited is from 1 to 5 tons.
 Mainly used in Flats , Apartments , Residence , Small
meeting halls.
CENTRALIZED AIRCONDITIONER

 Size of the 20 ton unit - 80 * 79 * 65 cm.


 Mainly used in Malls , Shopping centers , Hospitals.
 The Tonnage limited is 5 to 20 tons
FAN COIL UNIT

 Capacity: 0.6 kW – 3.90 kW – LOW BODY: Fan coil unit


with or without casing, designed for installation in
small niches.
 Capacity: 0.6 kW – 3.90 kW. – CONCEALED: Fan coil
unit without casing. Capacity: 0.6 kW – 11.72 kW.
 A fan coil unit (FCU) is a device that uses a coil and a
fan to heat or cool a room without connecting to
ductwork.
 Indoor air moves over the coil, which heats or cools
the air before pushing it back out into the room
DISTRICT COOLING SYSTEM

 District cooling system (DCS) distributes


cooling capacity in the form of chilled
water or other medium from a central
source to multiple buildings through a
network of underground pipes for use in
space and process cooling.
 Mainly used big apartment large shopping
malls
 Tonnage limited is from 12 to 90 ton
CHILLER PLANT SYSTEM

 HVAC systems are responsible for regulating the


comfort levels of most indoor environments, a
chiller plant act as a centralized cooling system
which provides cooling for a building or a number
of buildings.
 It is Mainly used in High rised building
 Types of chiller
 Air
 Water
 Evaportive
THANK YOU