ASENWARE LTD.

FM200 gas suppression system


(2169 series)
FM-200 Fire Suppression Systems

• Asenware FM-200 Fire extinguishing system are designed for total flo
oding to protect high value assets
• Colorless and non-toxic gas, suitable for normally occupied area, whe
re there is any chance of presence of human present
• FM200 fire suppression is also known as HFC227ea( 七氟丙烷 ). FM2
00 is a waterless fire protection system, it is discharged into the risk w
ithin 10 seconds and suppresses the fire immediately.
FM-200 Benefits
Use less space, save cost
(Compare CO2 system,FM200 system need only small amount of agent to put o
ut fire, so use less cylinder)

More quick to put out fire


(Within 10 seconds achieved, put out fire before they cause much damage)Clea
n agent, better protection room equipment
 
Life safety
(The FM200 agent put out fire on a molecular level, low pressure, no harm to h
uman)
FM200 maintain
The general useful life: 20 years
FM-200 - types

• Cabinet type • N2 network pipe type


• 40L,70L, 90L, 120L, 150L • 40L,70L, 90L, 120L, 150L
• 2.5MPa • 4.2MPa, N2 cylinder :6.0MPa
Cabinet Type Network Type
• 40L, 70L, 90L, 120L, 150L,180L • 40L, 70L, 90L, 120L, 150L,180L
• Pressure: 25 Bar (2.5 MPa) • Pressure: 42 Bar (4.2 MPa)
Is there any sub-floor or above ceiling in the room?
Yes →choose Network Type No→ choose Cabinet Type
Cylinder Tank Fill Range
FM-200 Applications
CLASS A concentration 6.7%
• library Archives room

• museums art galleries


FM-200 Applications
CLASS B concentration it is recommended to go through the NFPA
cup burner test result or contact Asenware to know the proper concentration for specific hazard.
FM-200 Applications
CLASS C concentration 7%

• Telecommunications room server room

• data processing center data processing center


FM-200 - How it works
• N2 network pipe type Fm 200 system:
• 1. automatic control
• 2. manual control
• 3. mechanical emergency start (need to be used in case of automatic sy
stem failure only , care must be taken when operate manually.)

Cabinet type Fm200 system:


• 1. automatic control
• 2. manual control
1. Automatic Operation

• When the control panel operate the solenoid valve upon receiving signal from detectors,
solenoid will actuate the cartridge after certain delay time ( if given ) and gas will discharge
into the hazard area.

• * With Asenware Gas Release Control Panel : Normally, the panel remains in ‘Auto’ positi
on.Upon receiving the signal from detectors , panel immediately released discharge alar
m and turn off the HVAC or dampers if any. And then release the gas after predetermine
d delay period.
2. Remote Manual Operation
• When the operation is performed by Manual Release Station, an appropriate pull stati
on is operated after detecting fire in the specific hazard area.

• With Asenware Gas Release Control Panel : Asenware Gas Release panel additionally p
rovide manual operation from panel , one must put the key to ‘manual’ position.
• After pushing the manual release located on the panel, gas will be released as operati
on
described above.
3. Local Manual Operation

• In case of failure of automatic actuation, Asenware FM-200 system ha


s the provision to operate it manually.
• In this scenario, one must proceed to appropriate FM-200 cylinders a
rrangements for specific hazard area. Remove the safety pull pin from
the pilot cylinder as instructed on the nameplate. And pull the lever a
nd gas will release immediately.
FM-200 - Principle of operation
Network pipe type FM 200 system

1.The control panel will operate upon activation of a ZONE1 and ZONE2 or press Manual
release station
2.control panel give signal to fire bell or storbe sounder (fire alarm) → delay period will
operate→ Selenoid valve will actuate the cartridge after certain delay time ( if given )
and then N2 gas release.
3.Pneumatic control valve (气动控制阀) is mounted on selector valve body to
operate when nitrogen pilot tank of specify hazard actuated→ N2 gas go through Gas
control pipe( 铜管 )to FM200 cylinder and then operate the FM200 cylinder→gas release
on High pressure soft tube( 高压软管 )
4.When the agent is discharged in the distribution piping, it pressurize the switch to
operate and give signal to control panel and control panel will give signal to warning
Signage ,its will flashing ,give information that ‘agent is released in the piping’→Finally
,Gas will be released to the room through the nozzle
FM-200 - Principle of operation
Cabinet type FM 200 system

1.The control panel will operate upon activation of a ZONE1 and ZONE2 or press Manual
release station
2.control panel give signal to fire bell or storbe sounder (fire alarm) → delay period will
operate→ Selenoid valve will actuate the cartridge after certain delay time ( if given )
and then release the FM200 gas
3.FM200 gas release on High pressure soft tube( 高压软管 ), When the agent is
discharged it pressurize the switch to operate and give signal to control panel and control
panel will give signal to warning Signage.it will flashing ,give information that ‘agent is
released in the piping’→Finally ,Gas will be released to the room through the nozzle
FM-200 - fire extinguisher control p
art
• Automatic gas extinguisher control system
• 1. AW-GEC2169 Automatic Gas Extinguisher Contr
ol Panel
• 2.Manual Release Station
• 3.Maintenance Switch
• 4. Gas Release Warning Signage
• 5. Conventional smoke detector, heat detector, bel
l, strobe sounder
AW-GEC2169 Automatic Gas Extinguisher Co
ntrol Panel
• AW-GEC2169 is upgrade from AW-GEC2159 with new design. The panel has 2 det
ection zones and new version has much more fashionable and easily operate butt
on from panel,also with safe and durable/visible metal cabinet with visible glass
window .

• The automatic extinguisher control panel AW-GEC2169 is designed execute Europ


ean standards of EN54-2 and EN54-4 Fire Detection and Fire Alarm systems clause
,and Control and Indicating Equipment EN12094-1 firefighting system standards.
AW-GEC2169 Gas Extinguishing
Control Panel Feature
Gas Extinguishing Release Control Panel AW-GEC2169

wring diagram
Gas Extinguishing Release Control Panel AW-GEC
2169
• Internal Terminal

ZONE1/ZONE2→connect Detector
EM VALVE →connect Selenoid valve
OPTICAL WARNING- →connect Gas Release
warning signage
SOUNDER OUTPUT → connect Bell or Strobe
Sounder
MODE SELECT→ connect Maintenance switch
MANUAL RELEASE→ connect Manual release
station
ABORT INPUT→connect PUSH/HOLD
RELEASED SWITCH→ connect pressure switch
Gas Extinguishing Release Control Panel AW-GEC
2169
• Battery Installation

The panel uses two lead acid gel 12V/2.3Ah batteries connected i
n series.

Connect the batteries with the supplied free lead and the Batterie
s to the power supply unit with the red (positive) and black (nega
tive) wires.

When the green battery LED is on steady it shows that the battery
condition and connections are normal.
Conventional Smoke Detector - Model no.:
AW-CSD381
• Wire connection point: No.6: Remote indicator(+) / Next detector IN (+) No.3:
Remote indicator(-). No.2: IN + ( zone input + ) No.5: IN - ( zone input - )
Conventional Heat Detector - Model no.: AW-CSD382
• Wire connection point: No.6: Remote indicator(+) / Next detector IN (+) No.3
: Remote indicator(-). No.2: IN + ( zone input + ) No.5: IN - ( zone input - )
Manual Release Station & Abort Switc
h
• Open the protection cover
• Press down the red button t
o trigger a manual release
• Reset by a key
• Open the protection cover
• Press the yellow button to
trigger an abort function
Fire Suppression System Manual Release Stat
ion
• Wire connection of Manual Release Station
• note:Resistance 6.8 KΩ and 470 Ω

470Ω

6.8 KΩ
Fire Suppression System Abort Switch
• Wire connection of PUSH/HOLD
• note:Resistance 6.8 KΩ and 470 Ω

6.8KΩ
Maintenance Switch
• This MAINTENANCE panel is
a key switch, which disconn
ects actuation circuits in the
system to prevent accidenta
l discharge during maintena
nce operations.

• When the key is inserted and


turned towards “SYSTEM
INACTIVE”, the red LED
illuminates and the green LED
indicating “SYSTEM ARMED”
turns off.
Maintance Switch
• Wire connection of Maintance Switch
• note: Resistance 6.8 KΩ and 470 Ω

6.KΩ
Gas Release Warning Signage

• AW-GRS2158 Gas Release W


arning Signage is a necessar
y part of automatic gas extin
guishing control system (A
W-GEC2169).

• By the fire alarm controller


to make it work, said gas
spraying, remind personnel
shall not enter areas of gas
fire extinguishing.
Wire connection of Gas Release warning S
ignage

10KΩ

warning Signage panel connect


*Note:need to connected 6.8K
resistor and Diode - IN4007
Conventional Bell - Model: AW-CBL216
6-A
• Wire connection of Bell
• note:JP1 jumper1 and 2 mean have Diode - IN4007,need to connected 6.8Kresistor
• JP2 jumper2 and 3 mean have 6.8K resistor,need to connected Diode - IN4007
Conventional Strobe Sounder - Model: AW-CSS2166-2
• Wire connection of Conventional Fire Strobe Sounder.
• DC power supply connection.
• End Resistance 6.8 KΩ.
Wire connection of Conventional Fire Strob
e Sounder and fire bell

strobe sounder & Bell panel connect


Wire connection of Solenoid Valve
*Note:need to connected 6.8k resistor and Diode - IN4007

10KΩ

_ +
Wire connection of Pressure switch
*Note:need to connect Resistance 6.8 KΩ and 470 Ω

6.8KΩ

470Ω
FM-200 Overview
Why choose Asenware
• 1. Our projects:
• Cambodia Power Substation FM200 System Project

• Myanmar Yangon Huawei Data Center Project

• Laos Telecommunication room fire system and environment monitoring


system

• All projects were designed and tchnical support by Asenware engineers.


Professional engineers design solutions

• 1. what is the usage of room?


• 2.Is there any sub-floor or above ceiling in the room?
• 3. please inform us the size of room, drawing CAD, PDF.
• We will design the best solution for you.