NFPA 20 Standard for the

Installation of Stationary
Pumps
for Fire Protection
By
Eng. Sherif Azab
Fire Protection Engineer

NFPA
‫بـعرـبـى‬
‫لاـ‬
00966552207243
00201100835897
Course Content
 Intro to NFPA 20. ‫بالعربى‬
‫شريف عزب‬.‫م‬
 Pump Basics.
 Installation of Suction Piping and Related Components.
 Installation Discharge Piping and Related Components.
 Sensing Line Requirement.
 Water Flow Test Devices.
 Pressure Maintenance Pump.
 Fire Pump Enclosure Requirements.
 Fire Pump Selection and Pressure setting.
 Water Sources.
Acceptance Testing
 Drivers and control Panels
NFPA 20-2016
‫بالعربى‬
Lecture-2 ‫شريف عزب‬.‫م‬

(Pump Requirements as per NFPA 20 -2016)


NFPA 20-2016
‫بالعربى‬
‫شريف عزب‬.‫م‬

 State The purpose of afire pump.

 Define centrifugal pump.

 Identify the types of centrifugal


pumps used for fire protection.

 State the application for each


type of centrifugal pumps
State the Requirement for installation
as per NFPA 20
NFPA 20-2016
‫بالعربى‬
Fire Pump Unit Driver ‫شريف عزب‬.‫م‬

Pump
Control
Panel
NFPA 20-2016
‫بالعربى‬
Purpose of a fire pump: ‫شريف عزب‬.‫م‬

Increases the water supply pressure at a desired flow


rate so that the water supply can utilize by sprinkler
and standpipe system
NFPA 20-2016
‫بالعربى‬
Pump Categories ‫شريف عزب‬.‫م‬

Centrifugal Pump
1-Increased pressure developed
by centrifugal force
2-Most common pump come
in wide range of types , sizes
and capacity

3-Can handle large volumes of


water while providing high
pressure
NFPA 20-2016
‫بالعربى‬
Types of Centrifugal Pump ‫شريف عزب‬.‫م‬

Horizontal Split
Case Pump

In-Line Pump

End Suction Pump


1-Flow is split and enters the impeller from
opposite sides.
Vertical Turbine
2-Shaft is horizontal and the impeller case
Pump
can be opened for maintenance.
3-Most common pump very reliable ,wide
Multistage
range of capacities and pressure can be used
multiport Pump
with any driver.
NFPA 20-2016
‫بالعربى‬
Types of Centrifugal Pump ‫شريف عزب‬.‫م‬

Horizontal Split
Case Pump

In-Line Pump
1-Useful where space is limited.
End Suction Pump 2-Less expensive but more
expensive for maintenance
Vertical Turbine 3-Limited capacity no more
Pump than 1500 gpm

Multistage 4-Can only used with an electric


multiport Pump driver
NFPA 20-2016
‫بالعربى‬
Types of Centrifugal Pump ‫شريف عزب‬.‫م‬

Horizontal Split
Case Pump

In-Line Pump

End Suction Pump 1-Discharge outlet perpendicular to


the suction outlet
2-Limited to capacity max 750 gpm
Vertical Turbine
Pump

Vertical Turbine
Pump
NFPA 20-2016
‫بالعربى‬
Types of Centrifugal Pump ‫شريف عزب‬.‫م‬

Horizontal Split
Case Pump

In-Line Pump  Can used with under ground


tanks ,lakes and river
End Suction Pump  Come in large wide of
capacity and pressure

Vertical Turbine  Can be used with any driver


Pump

Multistage
multiport Pump
NFPA 20-2016
‫بالعربى‬
Types of Centrifugal Pump ‫شريف عزب‬.‫م‬

Horizontal Split
Case Pump

In-Line Pump

End Suction Pump  Multi impeller connecting in a series in a single


case
 Multi outlet each outlet has different flow and
Vertical Turbine pressure
Pump  Fewer pumps being required
 Less pipe works and fewer valve
Multistage  One tank is sufficient if we have different zones
 Energy conservations
multiport Pump
NFPA 20-2016
‫بالعربى‬
General Requirements ‫شريف عزب‬.‫م‬

 Stationary pumps shall be selected based on the conditions


under which they are to be installed and used.

 Fire pumps shall be dedicated to and listed for fire protection service

 Certified shop test curves showing head capacity and brake horsepower
of the pump shall be furnished by the manufacturer to the purchaser
NFPA 20-2016
‫بالعربى‬
Pump Accessories ‫شريف عزب‬.‫م‬

4.10 Nameplate
 Pumps shall be provided with a
nameplate.

 The name plate shall be made of


and attached using corrosion
resistant material
NFPA 20-2016
‫بالعربى‬
Pump Accessories ‫شريف عزب‬.‫م‬

4.11 Pressure Gauges


 Suction and discharge gauges are used
to measure pressure on both sides of
the fire pump when in operation and
during the regularly scheduled non
flow testing required by NFPA 25. The
gauges should be of sufficient quality
to provide a reasonably accurate
pressure reading, since they are used
for testing purposes on a weekly and
sometimes annual basis. These gauges
should be calibrated each year to
maintain accuracy
NFPA 20-2016
‫بالعربى‬
Pump Accessories ‫شريف عزب‬.‫م‬

4.12 Circulation Relief Valve

 When a centrifugal fire pump is


operating at churn, energy is
continuously imparted to the
water in the impeller, causing the
water to heat. For electrical drive
fire pumps and radiator-cooled
engine–driven fire pumps, a listed
circulation relief valve is needed to
provide cooling water when the
pump is operating at churn.
NFPA 20-2016
‫بالعربى‬
Pump Accessories ‫شريف عزب‬.‫م‬

6.3.3 Automatic Air Release.


 Air in the impeller can cause
cavitations, damage the impeller,
and negatively impact the pump
performance.
NFPA 20-2016
‫بالعربى‬
Reference No. ‫شريف عزب‬.‫م‬

Chapter -3 Chapter 4
 3.3.44.3 4.1
 3.3.44.4 4.2
4.2.1
 3.3.44.8
4.4
 3.3.44.9 4.5
 3.3.44.10 4.10
 3.3.44.11 4.11
 3.3.44.12 4.12
 3.3.44.14 Chapter 6
6.3.3
 3.3.44.19
NFPA 20-2016
‫بالعربى‬
‫شريف عزب‬.‫م‬

Thanks
By
Sherif Azab
Fire Protection Engineer

NFPA
‫بـعـرـبـى‬
‫لاـ‬
00966552207243

You might also like