CloudEdge Solution (FusionSphere

OpenStack+E9000&2288&HP C700
0)
www.huawei.com

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved.


Contents

1. CloudEdge Solution Overview


2. NFVI Overview
3. Networking
4. Operation & Alarms
5. Glossary

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 3
Contents

1. CloudEdge Solution Overview


2. NFVI Overview
3. Networking
4. Operation & Alarms
5. Glossary

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 4
NFV Architecture Overview
Network functions virtualization
orchestrator (NFVO)
OSS/BSS and  Orchestrates network services (NSs) and
collaboration layer
• Service and operation
NFVO
NFVO VNF data packets.
(Manage
 Performs lifecycle management for NSs.
support (Manage NSNS
Lifecycles)
 Manages, authenticates, and authorizes
• Virtualized network Lifecycles)
NFVI resource requests.
function collaboration  Manages policies related to NS instances.

Virtualized network function manager


VNFM
VNFM (VNFM)
VNF VNF Virtualized
Virtualized Network
Network Function
Function (Manage
(Manage VNF
VNF
 Performs lifecycle management for VNF
• NE management instances.
(for
(for example,
example, CloudIMS/CloudEPC)
CloudIMS/CloudEPC) Lifecycles)
Lifecycles)
(U2000)  Provides overall coordination between the
• Virtualized NEs NFVI and EMS.

Virtualized infrastructure management (VIM)


Cloud
Cloud OS
OS
NFVI VIM
VIM  Controls and manages computing, storage,
(Hypervisor
(Hypervisor ++ Management
Management Module)
Module) (Provision and network resources.
(Provision
Virtualized
 Collects and reports infrastructure
NFVI Virtualized performance counters and events
• Virtualized resource Resources)
Resources)
pool (OpenStack/KVM)
Hardware
Hardware
• Hardware resource pool (Server/Storage/Network)
(Server/Storage/Network)
(E9000/HP/DELL...)
MANO
NFVI: VNF: MANO:
Network Function Virtualized Network Management and
Virtualized Infrastructure Function Orchestration

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 5
NFV Advantages

Now Future

Limited business Network resources open to third parties Broader opportunities


opportunities

Long time to market (TTM) Simplified network deployment Agile deployment

NFV
Software and hardware Products provided by  Software and
Layered management and operation multiple vendors on a per hardware
coupling decoupling
layer basis
 Automatic scaling
 Standardized open
interfaces
Purpose-built hardware Hardware resource sharing COTS

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 6
CloudEdge Solution Overview
 MANO: lifecycle management software in NFV mode
U2000
for the Huawei CloudEdge pre-integration solution
Service NE (VNF) MANO  FusionSphere OpenStack: a Huawei cloud
management platform that is developed based on the
NFVO OpenStack+KVM architecture. The UVP is Hypervisor
CloudUSN CloudUGW CloudCG in the FusionSphere solution and is KVM-based. The
KVM is the virtual machine based on the Linux Kernel.
VNFM It is a system management program that has been
merged into the Linux kernel. The KVM requires the
Third-party support of virtualized hardware extension processor,
CloudSCEF CloudEPSN app such as the Intel-VT processor, virtualized PPC, and
ARM processor.
 E9000: an enterprise-level server that performs the
functions of elastic computing and telecommunication
FusionSphere(UVP) VIM computing. It converges computing, storage, and
network resources to support operator and enterprise
high-end core applications.
E9000 2288 HP C7000  U2000: provides centralized configuration
maintenance, fault management, performance
management, and software management.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 7
CloudEdge Solution Overview
Management zone Service zone
Independent cluster Independent cluster Independent cluster

MNGVDC CloudEPC CloudMSE CloudSCEF


ServiceVDC01
MNGVPC
ServiceVPC_ ServiceVPC ServiceVPC Service ServiceVPC_SCEF
Manager
Fusion Manager

UGW _USN _EPSN VPC-APP


OpenStack
OpenStack

U2000

APP2
APP1
OMU
VNFM
U2000

OMU
APP2
APP1
OMU
VNFM

SDU
OMU
OMU

SPU

OMU
SDU
SPU
SDU
SPU

SDU
OMU
OMU

SDU

SPU
IPU
SPU

SDU
SPU
SDU
SPU

IPU
SDU

IPU
SPU
IPU
IPU

IPU
IPU
IPU
Fusion

Clusters
HA Mgt HA HA HA

CloudOS
FusionSphere
Storage 5500v3/HP 3PAR 8400

Management LUNs Service LUNs

COTS
E9000/2288/HP C7000

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 8
Contents

1. CloudEdge Solution Overview


2. NFVI Overview
3. Networking
4. Operation & Alarms
5. Glossary

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 9
Contents
2. NFVI Overview
2.1 FusionSphere OpenStack
2.2 E9000
2.3 2288
2.4 5500 V3
2.5 HP C7000
2.6 Switches

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 10
FusionSphere OpenStack
FusionSphere OpenStack is a Huawei OpenStack platform that
has enhanced functions based on the OpenStack Havana
version. Targeting on enterprise customers, FusionSphere
OpenStack is available for commercial use.

FusionSphere OpenStack inherits the openness and compatibility


of OpenStack and has the following characteristics:
 Supports computing, storage, network, and security
hardware devices from third-party vendors.
 Supports computing, storage, network, and security
resource virtualization products from third-party vendors.
 In regard to cloud services, FusionSphere OpenStack
provides OpenStack-based cloud services including
backup, live migration, affiliated resource scheduling,
telecom cloud service customization, and physical resource
pool expansion.
 In regard to O&M capabilities, FusionSphere OpenStack
provides OpenStack-based O&M services including
installation and deployment, upgrades and patching,
management data backup and restoration, information
collection, and health checks.

FusionSphere OpenStack incorporates the IT infrastructure and


service platform features required by both telecom operators and
ordinary enterprises and provides standard northbound interfaces
based on OpenStack.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 11
Automatic Discovery and Installation
 Large-scale fast installation
Supports plug-and-play.
 Automatic software loading and installation; Automatically discovers new X86 servers.
Takes only 80 minutes to complete installation on the
multi-nodes simultaneous installation. first node.

 Automatic control over the installation process; Takes only 40 minutes to complete installation on
100 physical servers. KVM/host OS and the
One-click operation. Install
OpenStack are installed from the management
OpenStack software.
Supports simultaneous installation on a maximum of
FusionSphere OpenStack
40 nodes within a L2 network.
Install
service Install
Host OS  Wide-range compatibility with mainstream X86
servers
Automatic installation applies to a wide range of
mainstream X86 servers.
Boot from
PXE

...

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 12
WebUI Installation and Cloud Automatic Deployment – Im
proving O&M Efficiency
Controller1 ControllerN Host1 Host2 HostN

Software Repository Openstack Openstack Openstack

OpenstackPackages Standard OS Interface


Web UI
HostOSPackages Control script Control script … Control script

Deployment Service

Native OpenStack Enhanced Huawei modules

Enhancement of OpenStack installation and deployment: Advantages and benefits:


 Provides a Web UI-based installation and deployment tool and supports one-click installation.  Supports one-click installation.
 Provides installation and deployment based on standard operating system interfaces, facilitating
 Supports heterogeneous hardware at a site.
OpenStack deployment on different operating systems and improving deployment flexibility.
 Supports automatic deployment of other OpenStack and FusionSphere management modules,  Supports role-based automatic and multi-node concurrent installation.
including automatic installation, uninstallation, start, termination, and restart of tasks and processes.  Enables hardware to be newly added to cloud within 15 minutes.
 Improves configuration efficiency of the administrator by providing complete configuration  Improves the capability of installing and deploying the open-source
management functions including unified frame and interface configuration, and configuration change
OpenStack and enhances installation and deployment efficiency.
notification.

WebUI Installation and Cloud Automatic Deployment – Improving O&M Efficiency

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 13
Unified Alarm Management U2000
1. Quickly detects OpenStack alarms based on the Huawei OpenStack alarm notification
Restful VNFMs only manage
mechanism. corresponding
2. Actively reports alarms for OpenStack faults. VNFM alarms and do not
act as forwarding SNMP alarm
3. Manages Ceilometer-defined alarms. channel. interface
OpenStack
4. Monitors infrastructure (servers, storage devices, or network devices) fault alarms.
Rest interface Rest/SNMP
Alarm interface
FusionSphere Fusion eSight
Manager
HTTP
Infrastruc
ture
Keystone OpenStack OMM
HTTP
service Glance Nova Cinder Neutron Heat
Swift Nova-Compute Cinder-Volume Neutron
Alarm Alarm
Driver Driver Plug-in Ceilometer Management Management
HTTP

Non-
Non-
Virtual VM
VM VM
VM VM
VM Storage Network virtualized
Storage Network
FusionNetwork virtualized
resource FusionCompute FusioSrage
virtualization
virtualization virtualization
virtualization resource
resource
UVP
SNMP

Key technology: The OpenStack service


Physical actively detects faults and reports alarms to
resource the OMM immediately. Then, the OMM
reports these alarms to the FM.
Physical
X86 server Storage Network
device

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 14
Contents
2. NFVI Overview
2.1 FusionSphere OpenStack
2.2 E9000
2.3 2288
2.4 5500 V3
2.5 HP C7000
2.6 Switches

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 15
E9000 Appearance

Item Specifications

Dimensions (Height x 530 mm x 442 mm x 840 mm


Width x Depth) (12U)

Color Black
530 mm
Empty weight: 70 kg
Weight
Fully configured: 220 kg

220 V AC
Rated input voltage
48 V DC

Rated input current 16 A


840 mm
442 mm Rated power
9000–15000 W
consumption

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 16
E9000 Front View
CH121/CH140 CH240/CH242/CH242 V3 CH220/CH221/CH222
1 1
8 6 8 6
1 1
7 5 7 5
1 1
6 6
4
1 4
1
5 5
3 3
1 1
4 4
2 2
1 1
3 1 3 1
1 1
2 2
0 0
1 9 1 9

Half-width slot number Full-width slot number (1) Full-width slot number (2)

Eight full-width or sixteen half-width compute nodes can be installed in front slots.
Numbering rules for slots of full-width compute nodes based on compute node types are as follows:
Slot numbers of the CH240, CH242, CH242 V3 in ascending order: 1–8. The CH24X series is not recommended.
Slot numbers of the CH220, CH221, CH222 in ascending order: 9–16. Full-width compute nodes of the CH220, CH221 and
CH222 are expanded from half-width compute nodes of the CH121. The CH222 V3 is used as the management node FS. Half-
width slots use CH121 V3, CH121H V3, or CH121 V5.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 17
E9000 Rear View

1E 2X 3X 4E
1 1 Identifier Description
3 4 1
6 6
3 2 Supports 2 management modules
1MM/2MM
2MM working in active/standby mode.
5 11

Supports two E\X switch modules.


1 5
2 4 If CH121 V3 is used, use CX310 in
0
2X and 3X; use CX710 in 1E and
3 9 1E/2X/3X/4E 4E.
1MM If CH121H V3 or CH121 V5 is used,
1 4 use CX920 in 2X and 3X; use
PSU 2 8 CX710 in 1E and 4E.

1 7
Fan module Fan module Supports 14 fan modules.

Supports 6 PSUs and N+N


PSU
redundancy mode.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 18
Half-Width CH121 V3 Compute Node
Item Half-Width 2P Blade Server with One Slot
Front view
Number of
1 or 2
processors
Processor
Intel Xeon E5-2600 v3 series (core option: 4, 6, and 8)
type

Memory slot 24 DDR4 DIMM slots with a maximum memory of 1.5 TB

Number of
Two 2.5-inch SSDs, SAS disks, or SATA disks
hard disks
Axial view
2 SATA DOMs
Mezz Card Onboard 2 Micro SDs (RAID 1) which can be removed or inserted without
storage opening the cover
1 USB flash drive (USB3.0)

Supported
RAID 0 and 1 (LSISAS2308 RAID card)
RAIDs

Supports expanding two PCIe x16 mezz cards.


PCIe
Supports expanding one PCIe x16 full-height half-length standard
PCIe expansion slot expansion
card.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 19
Half-Width CH121H V3 Compute Node
Front view Item Half-Width 2P Blade Server with One Slot

Number of processors 1 or 2

Processor type Intel Xeon E5-2600 v4 series (12 cores)

Memory slot 24 DDR4 DIMM slots with a maximum memory of 1.5 TB

Number of hard disks 2 x 2.5-inch HDD (SAS or SATA) or NVMe SSD disks

Axial view 2 SATA DOMs


Onboard storage 2 Micro SDs (RAID 1)
1 USB flash drive (USB3.0)

2 x 2.5-inch SAS or SATA disks, RAID 0 and RAID 1


Supported RAIDs 1 GB or 2 GB RAID Cache
LSI RAID 3008, 3108

Supports expanding two PCIe x16 mezz cards.


PCIe expansion Supports expanding one FPGA card.
Supports LOM, providing two 10GE Ethernet ports.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 20
Half-Width CH121 V5 Compute Node
Front view
Item Half-Width 2P Blade Server with One Slot

Number of processors 1 or 2

Processor type Intel Xeon Gold v5 series (14 cores)

Memory slot 24 DDR4 DIMM slots with a maximum memory of 1.5 TB


2 x 2.5-inch HDD (SAS or SATA) or NVMe SSD disks
Number of hard disks

Axial view 2 SATA DOM


Onboard storage
2 Micro SDs (RAID 1)
1 USB flash drive (USB3.0)

Supported RAIDS 2 x 2.5-inch SAS or SATA disks, RAID 0 and RAID 1


1 GB or 2 GB RAID Cache
LSI RAID 3508

Supports expanding two PCIe x16 mezz cards.


PCIe expansion
Supports expanding one FPGA card.
Supports LOM, providing two 10GE Ethernet ports.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 21
Comparison Between CH121 V3, CH121H V3,
and CH121 V5
CH121 V5 CH121H V3 CH121 V3
Half-width 2P blade server with one slot
Item Half-width 2P blade server with one slot Half-width 2P blade server with one slot

Processor type Intel Xeon Gold v5 series Intel Xeon E5-2600 v4 series Intel Xeon E5-2600 v3 series
Number of
2 2 2
processors
24 DDR4 DIMM slots with a maximum 24 DDR4 DIMM slots with a maximum 24 DDR4 DIMM slots with a maximum memory of
Memory slot memory of 1.5 TB memory of 1.5 TB 1.5 TB
Number of hard 2 x 2.5-inch HDD (SAS or SATA) or NVMe 2 x 2.5-inch HDD (SAS or SATA) or SSD 2 x 2.5-inch HDD (SAS or SATA) or SSD (SAS or
disks SSD disks (SAS or SATA) disks SATA) disks

Supported RAIDs RAID 0 and RAID 1 RAID 0 and RAID 1 RAID 0 and RAID 1

Supports expanding two mezz cards. Supports expanding two mezz cards. Supports expanding two mezz cards.
PCIe expansion
Supports expanding one FPGA card. Supports expanding one FPGA card. Supports expanding one PCIe standard card.
LOM 2 x 10GE 2 x 10GE N/A

2 SATA DOM
2 SATA DOM 2 SATA DOMs
2 Micro SDs (RAID 1)
Onboard storage 2 Micro SDs (RAID 1) 2 Micro SDs (RAID 1)
1 USB flash drive (USB3.0)
1 USB flash drive (USB3.0) 1 USB flash drive (USB3.0)

Dimensions 60.46 mm x 210 mm x 537.2 mm 60.46 mm x 210 mm x 537.2 mm 60.46 mm x 210 mm x 537.2 mm

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 22
LOM on CH121H V3 or CH121 V5
Comparing with CH121 V3, CH121H V3 and CH121 V5 are equipped with a LOM, which works together with the
switch boards to provide a 10 GE plane.

CH121 V5 CH121H V3 CH121 V3


Connections between mezz slots Connections between mezz slots Connections between mezz
and the switch boards and the switch boards slots and the switch boards

Backplane
Backplane Backplane
1E 1E 1E
MEZZ1 Mezz 1 Mezz 1

MEZZ2 Mezz 2 Mezz 2 2X


2X 2X

LOM LOM
3X
X722 82599 3X
3X

4E
4E
4E

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 23
CX310: 10GE Converged Switch Module CX310 Logical Architecture
Panel
Backplane
CX310

Downlink:
Serial 16 x (2 x 10GE) 10GE Uplink:
port Switch 16 x 10GE
Chip
Stacking over
the backplane:
Ethernet optical module: 1 x 40GE
SFP+ 10 Gbit/s: Used by a 10GE port;
single-mode or multimode LC fiber ports
SFP 1 Gbit/s: Used by a GE port;  10GE Ethernet L2/L3 switching:
single-mode or multimode LC fiber ports
 Supports 16 10GE ports in the uplink.
16 x  Supports 32 10GE ports in the downlink (two for each half-
Ethernet RJ45 electrical interface module:
10GE Used by a GE port; 1000 Base-T width slot)
SFP+ RJ45 twisted pair ports  Stackable:
port • Provides one 40GE port for module stacking over the
backplane.
DAC cable: Used by a 10GE port; • If you need a larger stacking bandwidth, you can add
Provided with interface modules;
Length: 1 m, 3 m, 5 m, 7 m, or 10 m stacking connections by using ports on the panel.
• Supports a maximum of four internal stacking switch
modules.
Note: The preceding modules and cables can be  Supports L2/L3 switching.
deployed on the SFP+ ports at the same time.
 Converged switching:
 Supports DCB (PFC, ETS, DCBX) and TRILL.
 Supports FIP Snooping Bridge (FSB).
 The two CX310s in a pair of slots can implement independent
switching, work in 1+1 redundancy mode, or work in load sharing
mode by working with the operating system (OS) and network
interface cards (NICs).

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 24
CX710: 40GE Converged Switch Module

 Uplink
8 x 40GE
6 of them can be each divided into four 10GE
ports.
 Downlink
STAT 16 x 40GE

HLY Each 40GE port can be dynamically divided


BMC
into two 10GE ports. The ports are compatible
2 x RJ45

Backplane
with 10GE mezz card.
 Backplane direct links
2 x 40GE (can be used to stack devices or as
interconnection channels)

8x 40GE  Mezz card type: MZ710


QSFP+ Ethernet

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 25
CX920: Multi-Plane Switch Module
The CX920 switch module (referred to as CX920) is the switching control unit that provides data
switching for server blades and provides external service and management ports in a centralized manner.
The 10GE and 40GE switching planes are physically isolated from each other and work independently.
The 10GE switching plane connects to the LOMs of blades (Currently only the CH121H V3 server
supports LOMs). The 40GE switching plane connects to mezzanine card 1 or 2 of blades.
The CX920s are installed in the rear slots of the E9000 chassis. They are installed in slots 2X and 3X. If
they are installed in slots 1E and 4E, the 10GE switching plane is unavailable. Through the E9000
chassis backplane, the CX920s are connected to the compute nodes, storage nodes, and management
modules to implement switching for internal data packets and management packets, providing high-
speed data transmission for users.

The CX920 logical architecture consists of four modules: baseboard management controller (BMC)
module, CPU system module, 10GE switch module, and 40GE switch module, as shown in the figure on
the left. The BMC powers on and off nodes and modules, monitors the system, and upgrades
components.
The CPU system module is the controlling core for the CX920. It processes network protocol packets and
manages user configuration.
The 10GE and 40GE switch modules are the data processing core of the CX920. They forward data
between internal data processing modules and external network devices.
 Uplink: 8 x 40GE + 8 x 10GE
 Downlink: 16 x 40GE + 16 x 10GE
 Backplane direct links
2 x 40GE (40GE switching plane) + 1 x 40GE (10GE switching plane)
 Mezz card type: MZ710 and LOM

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 26
Contents
2. NFVI Overview
2.1 FusionSphere OpenStack
2.2 E9000
2.3 2288
2.4 5500 V3
2.5 HP C7000
2.6 Switches

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 27
2288 Appearance

The 2288 is a general-purpose 2U dual-socket rack server launched to meet


requirements of the Internet, Internet data center (IDC), cloud computing,
enterprise market, and telecom service applications.

The 2288 applies to IT core services, cloud computing virtualization, high-


performance computing, distributed storage, big data processing, enterprise or
telecom service applications, and other complex workloads. This server features
low power consumption, high scalability and reliability, and easy management, and
deployment.

Currently, the RH2288H V3 and 2288H V5 are used in CloudEdge.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 28
Front Panel of the RH2288H V3 with 25 2.5-
Inch Hard Disks

1 Fault diagnosis LED 2 Health indicator

3 UID button/indicator 4 Power button/indicator

Hard disks (numbered 0 to 24 from left


5 Customized label 6
to right)

7 USB 2.0 port 8 Network port link status indicator 4

9 Network port link status indicator 3 10 Network port link status indicator 2

11 Network port link status indicator 1 12 Hard disk fault indicator

13 Hard disk activity indicator - -

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 29
Rear Panel of the RH2288H V3

1 PSU 2 PSU indicator


I/O module 2 (providing slots 6 to 8 from
top to bottom) or NVMe PCIe SSD
3 Power socket for a PSU 4
adapter (corresponding to CPU 2, providing slots 6 and 7 from top
to bottom)
5 Connection status indicator 6 Data transmission status indicator
Onboard PCIe slots (numbered
7 8 I/O module 1 (providing slots 1 to 3 from top to bottom)
4 and 5 from left to right)
9 LOM 10 UID indicator
11 USB 3.0 port 12 Mgmt management network port
13 VGA port 14 Serial port

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 30
Front Panel of the 2288H V5 with 25 2.5-
Inch Hard Disks

2 Fault diagnosis LED


1 Network port link status indicators
(numbered 1 to 4 from top to bottom)

3 Health indicator 4 UID button/indicator

5 Power button/indicator – –

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 31
Front Panel of the 2288H V5

Or

1 10GE electrical port 2 10GE optical port

3 VGA port 4 GE electrical port

5 Management network port 6 Serial port

7 USB 3.0 port 8 PSU port

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 32
RH2288H V3 and 2288H V5 Specifications Comparison
Type Sub-category RH2288H V3 2288H V5
Chassis N/A N610E-22 N610E-22

Model RH2288H V3 (25 hard disk chassis EXP) H22H-03 2288H V5 (25 hard disk chassis EXP) H22H-05

CPU 2 x E5-2658A V3 (Haswell-EP 12 cores)/2 x E5-2658 V4 (Broadwell-14 cores) 2 x 5120 TB

Memory 16 x 16 = 256 GB DDR4 8 x 32 = 256 GB DDR4

Hard disk 2 x 800 GB SSD 2 x 800 GB SSD

RAID card LSI3108 LSI3508

Management Onboard NIC 2 x 10GE optical ports (82599). The NIC is used for NFVI management and storage. 2 x 10GE optical ports. The NIC is used for NFVI management and storage.
server
Extended NIC 1 SP310 (Intel 82599 2 x 10GE). The NIC is used for services. SP330 (IntelX710 2 x 10GE). The NIC is used for services.

Extended NIC 2 N/A N/A


For delivery outside China, the TPM (Infineon chip) is delivered. For delivery in China, the
TPM N/A
TPM is not delivered.

Model RH2288H V3 (25 hard disk chassis EXP) H22H-03 2288H V5 (25 hard disk chassis EXP) H22H-05

CPU 2 x E5-2658A V3 (Haswell-EP 12 cores)/2 x E5-2658 V4 (Broadwell-14 cores) 2 x 5120 TB (14 cores, recommended)

Memory 16 x 16 = 256 GB DDR4 8 x 32 = 256 GB DDR4

Hard disk 2 x 600 GB SAS, 2.5. rear disk 2 x 600 GB SAS, 2.5. rear disk

RAID card LSI3008 LSI3408

Onboard NIC 2 x 10GE optical ports (82599). The NIC is used for NFVI management and storage. 2 x 10GE optical ports. The NIC is used for NFVI management and storage.
Service server
Extended NIC 1 SP310 (Intel 82599 2 x 10GE). The NIC is used for services. SP330 (IntelX710 2 x 10GE). The NIC is used for services.

Extended NIC 2 SP310 (Intel 82599 2 x 10GE). The NIC is used for services. SP330 (IntelX710 2 x 10GE). The NIC is used for services.

For delivery outside China, the TPM (Infineon chip) is delivered. For delivery in China, the
TPM N/A
TPM is not delivered.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 33
Contents
2. NFVI Overview
2.1 FusionSphere OpenStack
2.2 E9000
2.3 2288
2.4 5500 V3
2.5 HP C7000
2.6 Switches

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 34
5500 V3 Overview
 The OceanStor V3 series uses a new Pangea V2R1C00/C01 hardware platform.
 5500 V3: disk and controller integration (2U)

5500 V3
Name Description
Processor (single controller) One 6-core processor
Cache capacity (single controller) 48 GB or 128 GB
Max. number of controllers per subrack 2
2U SAS enclosure,
Disk enclosure type supporting 25 2.5-inch
disks

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 35
5500 V3 Controller Enclosure with 25 Disk Slots

Icon Description on the Left Icon Icon Description on the Disk Unit Icon Description on the Right Mounting
Icon Icon
Mounting Ear Ear
1. Disk powered off: off
Disk slot label (The 2. Disk working properly: steady on green Enclosure ID indicator
left figure indicates (when the disk is powered on and
that the controller performs data reading and writing) Enclosure location indicator
enclosure supports 3. Disk alarms reported: steady on red 1. Enclosure not being located: off
25 disk slots.) 4. Disk to be invalid: blinking red (0.5 Hz) 2. Enclosure being located: blinking
5. Disk being located: blinking blue (2 Hz) blue (2 Hz)
Wi-Fi button
(reserved but not Enclosure alarm indicator
supported) Disk type label 1. No alarm reported: off
2. Alarms reported: steady on red

Power indicator/Power button


1. System powered off: off
Note: The numbers of slots on a 2U 25-slot controller enclosure range from 0 to 24. The numbers 2. System powered on: steady on
of slots for installing coffers range from 0 to 3. green

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 36
Ports on the Rear Panel of the 5500 V3

Serial port

USB port Configuration


SAS expansion port
 A controller provides network port
 A controller provides
Module integrated with the
two SAS expansion one USB port Management
PSU, BBU, and fan
ports. (reserved for future network port
 Supports 1+1 redundancy mode.
use)
 The power conversion efficiency
reaches 94%. Port module
 A BBU can be replaced  A controller provides two slots for installing port modules.
Board-mounted daughter card port
independently.  The 5500 V3 supports four 8G  Supports hot swapping.
 Supports –48 V and 240 V DC.  Type: 16 Gbit/s FC, 12 Gbit/s SAS, GE, 10GE TOE, 10GE FCoE, and 8
FC ports.
Gbit/s FC

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 37
2U 2.5-Inch Disk Enclosure

2.5-inch disk unit


 Converter-free

 Supports 6G SAS/NL-

SAS/6G SAS SSD.

Expansion module
 Dual-expansion board

 12G SAS in the

uplink/downlink

600 W PSU
 Supports the 1+1 redundancy

1 2 3 mode.
 Integrates the fan of the disk

enclosure (1+1 redundancy


1 Serial port 2 Mini SAS HD expansion port 3 Disk enclosure ID display mode; one fan per PSU).
 Supports DC/AC power supply.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 38
Contents
2. NFVI Overview
2.1 FusionSphere OpenStack
2.2 E9000
2.3 2288
2.4 5500 V3
2.5 HP C7000
2.6 Switches

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 39
HP Blade System C7000 Enclosure
Industry-leading blade density
Hosts up to 16 half-width or 8 full-width blades

Local storage blade PARSEC-based heat dissipation system

8 interconnect modules
GE and 10GE
4Gb SAN, iSCSI
Infiniband interconnects
10U Pass-thru module

Powerful onboard administrator management module,


Unique Insight Display screen capable of managing multiple enclosures
N+N power supply redundancy; Supports both single- and three-phase input

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 40
HP C7000 BL460C Gen9 (Half Width)
Item Half-width blade server

Number of processors 1 or 2

Processor type Intel® Xeon® E5-2600 v3 or v4

16 DDR4 DIMM slots with a maximum memory


Memory slot
of 2 TB

Number of hard disks 2 x 2.5-inch SSD, SAS or SATA hot-plug disk

HPE Smart HBA H244br Controller with RAID 0


Supported RAID
and RAID 1

PCIe expansion 2 x16 PCIe slots

Internal View
1. FlexibleLOM adapter
2. Nand Flash & Micro SD
3. Mezzanine Slots (x16 PCI 3.0) Connector
4. Sixteen (16) DDR4 DIMM slots (8 per processor)
5. Up to two (2) Intel? Xeon? E5-2600 v3 or v4 family processors
6. HPE BLc 12W Smart Storage Battery connector
7. USB 3.0 and TPM
8. Embedded SATA Connector
9. Solid State Device
10. Two hot-plug drive bays
11. HPE Smart Array P244br Controller with 1GB FBWC
12. iLO Management Engine

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 41
HP BLc VC FlexFabric-20/40 F8

Features:
 16 x 10/20Gb Ethernet downlinks to server blade NICs and

FlexFabric Adapters. Each 10/20Gb downlink supports up


to 3 FlexNICs and 1 FlexHBA or 4 FlexNICs.
 8xSFP+ external uplink ports configurable as either 1/10Gb

Ethernet or 2/4/8Gb auto-negotiating Fibre Channel


connections to external LAN or SAN switches.
 4xQSFP+ external uplink ports configurable as 1x40Gb or

4x10Gb Ethernet connected to external LAN switches.


 2 x 20Gb cross connects for stacking.

 MTU up to 9216 Bytes - Jumbo Frames.


 Supports up to 128K MAC entries.

1. Module status 12. X1-X4 Flexports


2. Module locator (UID) 13. X7-X8 paired Flexports
3. Q1-Q4 QSFP+ 40Gb ports 14. X5-X6 paired Flexports
4. L/A 15. X8 port status
5. PID 16. X7 port status
6. FC mode 17. X6 port status
7. Ethernet 18. X5 port status
8. X1 port status 19. Fourth 10Gb port status for QSFP+ Q4 in 4x10 mode
9. X2 port status 20. Third 10Gb port status for QSFP+ Q4 in 4x10 mode
10. X3 port status 21. Second 10Gb port status for QSFP+ Q4 in 4x10 mode
11. X4 port status 22. First 10Gb port status for QSFP+ Q4 in 4x10 mode

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 42
HP 6125XLG Ethernet Blade Switch

1. Ejector Lever Features:


 240Gb uplink bandwidth / 160Gb available server side bandwidth
2. Four (4) 40 GbE (QSFP+) ports
 Separate 4 x10Gb Internal cross-connect between switches
3. Release tab
 4 x 40GE QSFP+ and 8 x 10GE SFP+ over uplink
4. Eight (8) 10 GbE (SFP+) ports
 Wire-speed switching and IPv4/IPv6 routing on all ports
5. Reset button
 Supports FCoE N_Port Virtualization (NPV) and Fibre Channel Forwarder (FCF) modes
6. Console port
7. Port LED  Supports FCoE FIP Snooping mode
 Supports RoCE
8. Health LED
 QSFP+ ports support 4 x 10Gb with optional breakout cable
9. Unit ID (UID) LED
 SFP+ ports support either 1Gb or10Gb depending on module inserted

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 43
Adapter for HP BL460C Gen9

Type Specifications Recommendation

Dual 20Gb ports provide up to 80Gb bi-directional per adapter

Multi-speed adapter operates at either 20GbE or 10GbE

Converges FCoE or RoCE with LAN traffic on a single Ethernet wire

Mixed Storage - supports NIC + FCoE on one port, and NIC + iSCSI
on the other
HPE FlexFabric Virtual Connect
20Gb 2-port 650FLB Adapter 20Gb 2-port FlexFabric-20/40 F8
650FLB Adapter Concurrent Storage - concurrently supports NIC, FCoE, and iSCSI Module
storage functions on the same port (NIC + FCoE + iSCSI)

Jumbo Frames support

User configurable bandwidth settings when combined with the 20Gb


Flex-20 Virtual Connect module. From 100Mb/s to10Gb/s on up to
eight "Physical Function" NICs per port, in increments of 100Mb/s for
NIC.

Dual 10Gb ports provide up to 40Gb full duplex per adapter


10Gb 2-port Hardware and software acceleration and intelligent offloads for HPE 6125XLG
560M Adapter stateless TCP/IP Jumbo frames support Ethernet Blade Switch
support DPDK
10Gb 2-port 560M Adapter

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 44
HP BL460C Gen9 Onboard Ports Connections
 HP C7000 BL460C Gen9 supports LOMs. (If FC SAN is used, 650FLB is recommended.)
 BL460C Gen9 has to mezz slots for expansion.
 The backplane hosts up to eight half-width switch modules.
The example configuration here includes one 650FLB LOM, two 560M mezz cards, and six half-width switch modules.
Connections between BL460C Gen9 mezz
slots and switch modules

LOM
Backplane
Bay1 Bay2 Port 1 connects to Bay 1. Port 2 connects to Bay 2. Bay
LOM
650FLB
1 and Bay 2 can be stacked.

Mezz 1 (560M)
Bay3 Bay4 Port 1 connects to Bay 3. Port 2 connects to Bay 4.
Bay 3 and Bay 4 can be stacked.
MEZZ1
560M
Mezz 2 (560M)
Bay5 Bay6 Port 1 connects to Bay 5. Port 2 connects to Bay 6. Bay
5 and Bay 6 can be stacked.
MEZZ2
560M
Mezz 2 (with 4 ports)
Bay7 Bay8 Ports 3 and 4 connect to Bay 7 and Bay 8. However, Bay
7 and Bay 8 are not used in CloudEdge.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 45
Contents
2. NFVI Overview
2.1 FusionSphere OpenStack
2.2 E9000
2.3 2288
2.4 5500 V3
2.5 HP C7000
2.6 HP 3PAR 8000
2.7 Switches

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 46
HPE 3PAR StoreServ 8000 Storage 

3Par 8400 rear view


3Par 8400 Front View
Supports up to four controllers

Drive layout Controller ports:


24 disks per row (0-23) 1: GE ports 2: Fabric channels 16Gb FC-1/FC-2
(The 8400 model supports 48 disks per row) 3: SAS port DP-1/DP-2 4: Cluster interconnect links
Slots: 2.5- or 3.5-inch SAS, 2.5-inch SSD 5: MFG 6: PCI-HBA: PCIe expansion slot

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 47
Contents
2. NFVI Overview
2.1 FusionSphere OpenStack
2.2 E9000
2.3 2288
2.4 5500 V3
2.5 HP C7000
2.6 HP 3PAR 8000
2.7 Switches

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 48
CE6855HI

Front (power supply side)

Rear (port side)

Left side

Right side

In standard configurations, the CE6855HI is a TOR for CloudEdge V100R018C10 and can be used as an EOR
in small-capacity scenarios.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 49
CE6855HI (Cont.)
Power supply slot 1 Power supply slot 2
Applicable power modules: Applicable power modules:
1 350 W DC power module
2 350 W DC power module

600 W AC power module 600 W AC power module

Fan slot 1 Fan slot 2


3 4
Applicable fan modules: FAN-40EA series fan modules Applicable fan modules: FAN-40EA series fan modules
5 Console port 6 ETH management port (RJ45)
ESN label
7 Note: This label is drawable, and you can pull it outward to view the ESN and 8 USB port
MAC address of the switch.

Forty-eight 10GE SFP+ Ethernet optical ports Six 40GE QSFP+ Ethernet optical ports
Applicable transceiver modules and cables: Note:
 10GE optical module (OSXD22N00 and LE2MXSC80FF0 not supported) A 40GE QSFP+ port can be split into four 10GE ports.
 10GE-CWDM optical module Applicable modules and cables:
9  GE optical module 10 40GE optical module

 GE-CWDM optical module 10 m QSFP+ AOC cable (QSFP+ to QSFP+)

 GE copper transceiver module (only working at 1000 Mbit/s) 1 m, 3 m, and 5 m QSFP+ copper cables (QSFP+ to 4*SFP+)

 3 m, 10 m, and 20 m SFP+ AOC cables 1 m, 3 m, and 5 m QSFP+ copper cables (QSFP+ to QSFP+)

 1 m, 3 m, 5 m, 7 m (active), and 10 m (active) SFP+ copper cables

11 Three port-side mounting holes for mounting brackets 12 Four power-supply-side mounting holes for mounting brackets
13 Ground screw - -

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 50
CE6851HI

In standard configurations, the CE6851HI is a


TOR for the CloudEdge V100R017C10 or
V100R018C00 and can be used an EOR in
small-capacity scenarios.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 51
CE6851HI (Cont.)
Power supply slot 1 Power supply slot 2
Applicable power modules: Applicable power modules:
1 350 W DC power module
2 350 W DC power module

600 W AC power module 600 W AC power module

Fan slot 1 Fan slot 2


3 4
Applicable fan modules: FAN-40EA series fan modules Applicable fan modules: FAN-40EA series fan modules
5 Console port 6 ETH management port (RJ45)
ESN label
7 Note: This label is drawable, and you can pull it outward to view the ESN and 8 USB port
MAC address of the switch.

Forty-eight 10GE SFP+ Ethernet optical ports Six 40GE QSFP+ Ethernet optical ports
Applicable transceiver modules and cables: Note:
 10GE optical module (OSXD22N00 and LE2MXSC80FF0 not supported) A 40GE QSFP+ port can be split into four 10GE ports.
 10GE-CWDM optical module Applicable modules and cables:
9  GE optical module 10 40GE optical module

 GE-CWDM optical module 10 m QSFP+ AOC cable (QSFP+ to QSFP+)

 GE copper transceiver module (only working at 1000 Mbit/s) 1 m, 3 m, and 5 m QSFP+ copper cables (QSFP+ to 4*SFP+)

 3 m, 10 m, and 20 m SFP+ AOC cables 1 m, 3 m, and 5 m QSFP+ copper cables (QSFP+ to QSFP+)

 1 m, 3 m, 5 m, 7 m (active), and 10 m (active) SFP+ copper cables

11 Three port-side mounting holes for mounting brackets 12 Four power-supply-side mounting holes for mounting brackets
13 Ground screw - -

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 52
CE7850

The CE7850 can function as the EOR in the CloudEdge solution for Telekom Austria (currently, the CE7850
is not included in the standard configurations).

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 53
CE7850 (Cont.)

Power supply slot 1 Power supply slot 2


1 2
Applicable power module: 600 W AC power module Applicable power module: 600 W AC power module

Fan slot 1 Fan slot 2


3 4
Applicable fan modules: FAN-40HA series fan modules Applicable fan modules: FAN-40HA series fan modules

5 Console port 6 ETH management port (RJ45)

ESN label
7 Note: This label is drawable, and you can pull it outward to view the 8 USB port
ESN and MAC address of the switch.

Thirty-two 40GE QSFP+ Ethernet optical ports


Note: A 40GE QSFP+ port can be split into four 10GE ports.
Applicable modules and cables:
9  40GE optical module 10 Three port-side mounting holes for mounting brackets
 10 m QSFP+ AOC cable (QSFP+ to QSFP+)
 1 m, 3 m, and 5 m QSFP+ copper cables (QSFP+ to 4*SFP+)
 1 m, 3 m, and 5 m QSFP+ copper cables (QSFP+ to QSFP+)

11 Four middle mounting holes for mounting brackets 12 Four power-supply-side mounting holes for mounting brackets

13 Ground screw - -

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 54
CE12804S
1. Two MPUs
2. Four interface
boards
3. Two switching
boards

The CE12804S is used as the EOR of the CloudEdge. It applies to all current CloudEdge versions.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 55
CE12804S (Cont.)
Slot Type Slot ID Module Supported Remarks

 E line cards:
CE-L24LQ-EC1 24*40G
CE-L48XS-EC 48*10G
CE-L04CF-EF 4*100G
The cards match blades of class C.
LPU slots Slot 1 to slot 4 LPUs provide GE, 10GE, 40GE and 100GE ports.
 F line cards:
CE-L48XS-FD/FDA 48*10G
CE-L36LQ-FD 36*40G
CE-L12CQ-FD 12*100G
The cards match blades of class F.

MPU slots Slot 5 to slot 6 CE-MPUA-S MPUs work in 1:1 hot backup mode.
SFUs complete switching of service data in the entire system and work in
SFU slots Slot 7 to slot 8 2 CE-SFU-S cards
load balancing and redundancy mode.
The AC&high-voltage DC chassis can support a maximum of four 3000 W
AC&high-voltage DC chassis: 3000 W AC&high-voltage DC power modules. The DC chassis does not support
Power module
PM1 to PM4 AC&high-voltage DC power module such a power module.
slots
DC chassis: 2200 W DC power module 2200 W DC power module: –48 V DC/–60 V DC input; 48.5 V DC/2200 W
output
Fan module slots FAN1 to FAN3 FAN-600A-B fan module Standard configuration: 3

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 56
CE12808S
Front Rear

1. Two MPUs
2. Eight interface boards
3. Four switching boards

Socket 8 Socket 7 Socket 6 Socket 5


Socket 4 Socket 3 Socket 2 Socket 1

Area A Area B Area B Area A


As the EOR of the CloudEdge, the CE12808S is introduced in the later phase of the CloudEdge V100R018C00 and co-exists with
the CE12804S. The specifications of the CE12808S are twice those of the CE12804S.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 57
CE12808S (Cont.)
Slot Type Slot ID Module Supported Remarks
LPU slots Slot 1 to Slot 8  E line cards: LPUs provide GE, 10GE, 40GE and 100GE ports.
CE-L24LQ-EC1 24*40G
CE-L48XS-EC 48*10G
CE-L04CF-EF 4*100G
The cards match blades of class C.
 F line cards:
CE-L48XS-FD/FDA 48*10G
CE-L36LQ-FD 36*40G
CE-L12CQ-FD 12*100G
The cards match blades of class F.
MPU slots Slot 9 to Slot 10 CE-MPUA-S MPUs work in 1:1 hot backup mode.
Slot 11 to Slot 14 4 CE-SFU-S cards SFUs complete switching of service data in the entire
SFU slots system and work in load balancing and redundancy
mode.
PM1 to PM8 AC&high-voltage DC chassis: 3000 W The AC&high-voltage DC chassis can support a
AC&high-voltage DC power module maximum of eight 3000 W AC&high-voltage DC
Power module DC chassis: 2200 W DC power module power modules. The DC chassis does not support
slots such a power module.
2200 W DC power module: –48 V DC/–60 V DC
input; 48.5 V DC/2200 W output
Fan module slots FAN1 to FAN6 FAN-600A-B fan module Standard configuration: 6

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 58
Contents

1. CloudEdge Solution Overview


2. NFVI Overview
3. Networking
4. Operation & Alarms
5. Glossary

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 59
Contents
3. Networking
3.1 E9000 Networking
3.2 2288 Networking
3.3 HP C7000 Networking

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 60
E9000 Physical Networking

1. NFVI management & storage traffic is routed to the


CE6855 switches through the switch modules in slots 2X
Management traffic and 3X.
PE1 PE2 Storage traffic
2. For CH121 V3 blades, service, OM, vFabric, and vBase
traffic is routed to the TOR switches through switch
Service traffic modules in slots 1E and 4E.
For CH121 V5 or CH121H V3 blades, service and OM
traffic is routed to the TOR switches through switches
EOR
modules in slots 1E and 4E, and vFabric and vBase
traffic is routed to EOR switches through switch modules
in slots 2X and 3X.
3. E9000 hardware management traffic generated by
CE6855
MM910 is routed to the CE6855 switches.
4. Hardware management and storage traffic of S5500 V3
disk arrays is also routed to the CE6855 switches.
IP SAN
5500 V3

E9000 E9000

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 61
E9000 Cable Connections When CH121 V3 Blades Ar
e Used
External
ports for
External ports for External ports for service External ports for
service
mgmt. traffic and OM traffic management traffic
and OM
traffic

10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE


40GE 40GE

EOR EOR
40GE 40GE
40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE
40GE 40GE 40GE 40GE
Stack

5500 V3 5500 V3
Controller A Controller B Controller A Controller B External ports for
storage&mgmt. traffic
GE 10GE 10GE 10GE 10GE GE 10GE 10GE 10GE 10GE GE 10GE 10GE 10GE 10GE GE 10GE 10GE 10GE 10GE

Ports for Ports for Ports for Ports for


storage&mgmt.traffic storage data storage$mgmt. traffic storage data
External ports for External ports for service Ports for Ports for External ports for service
storage&mgmt.traffic and OM traffic vFabric&vBase traffic vFabric&vBase traffic and OM traffic

40GE 40GE 40GE 40GE

Ports for GE
10GE 10GE 10GE 10GE GE
10GE 10GE 10GE 10GE 40GE
GE
10GE 10GE 10GE 10GE GE 10GE 10GE 10GE 10GE Ports for
40GE
hardware hardware
management CE6851-1 Ports for NFVI management traffic Ports for storage data Ports for storage data Ports for NFVI management traffic CE6851-2 management
10GE 10GE 10GE 10GE 10GE 40GE 40GE 10GE 10GE 10GE 10GE 10GE
GE GE

Stack

GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 40GE 40GE 40GE 40GE 40GE 40GE GE
40GE 40GE 40GE 40GE 40GE 40GE

40GE
40GE
MM910- 1 CX710(1E) CX310(2X) 40GE 40GE CX310(3X) CX710(4E) MM910- 2
Stack
40GE 40GE
40GE 40GE 40GE 40GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 40GE 40GE 40GE 40GE

Stack Stack

Ports for Ports for Ports for


10GE 10GE 40GE 40GE 40GE 40GE Storage&Mgmt. 10GE
Mgmt. ports Storageports north-south east-west Stack ports north-south
ports
traffic traffic traffic

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 62
E9000 Cable Connections When CH121 V5 or CH121
H V3 Blades Are Used
Router(Customer)-1 Router(Customer)-2
10GE 10GE 10GE/100 10GE/100 10GE/100 10GE/100
10GE 10GE
GE GE GE GE

External
External ports External ports for service
ports for
for mgmt. traffic and OM traffic External ports for
service
management traffic
and OM
traffic

10GE/100 10GE/100 10GE/100 10GE/100


10GE 10GE 10GE 10GE
GE GE GE GE
40GE 40GE

CE12804S/CE8860 CE12804S/CE8860
40GE 40GE
40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE
40GE 40GE Stack 40GE 40GE

5500 V3 5500 V3
Controller A Controller B Controller A Controller B External ports for
storage&mgmt.traffic
GE 10GE 10GE GE 10GE 10GE GE 10GE 10GE GE 10GE 10GE

Ports for Ports for Ports for


Ports for storage data
storage&mgmt.traffic storage data storage&mgmt.traffic
External ports for
storage&mgmt.traffic
External ports for service Ports for vFabric&vBase Ports for External ports for service
and OM traffic traffic vFabric&vBase traffic and OM traffic
40GE 40GE 40GE 40GE

GE GE GE GE
10GE 10GE 10GE 10GE 40GE 10GE 10GE 10GE 10GE
40GE
Ports for hardware Ports for NFVI
management traffic CE6851-1 management traffic Ports for storage data Ports for storage data Ports for NFVI management traffic CE6851-2
10GE 10GE 10GE 10GE 10GE 40GE 40GE 10GE 10GE 10GE 10GE 10GE
GE GE

Stack

GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 40GE 40GE 40GE 40GE 40GE 40GE GE
40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE

40GE 40GE
40GE
MM910- 1 CX710(1E) CX920(2X) Stack 40GE CX920(3X) CX710(4E) MM910- 2
40GE
40GE
40GE 40GE 40GE 10GE 10GE 40GE 40GE 40GE 40GE 10GE 10GE 40GE 40GE 40GE

Stack Stack

Ports for Ports for Ports for


10GE 10GE 40GE 40GE 40GE 40GE Storage&Mgmt. 10GE
Mgmt. ports Storageports north-south east-west Stack ports north-south
ports
traffic traffic traffic

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 63
E9000 Cabinet Layout – N610E-22 DC Cabinets
N610E-22 N610E-22 N610E-22 N610E-22
One cabinet with two chassis One cabinet with two chassis One cabinet with two chassis One cabinet with one chassis
Dual 6-inputs (DC 63 A for each input) supply
Dual 6-inputs (DC 63 A for each input) supply power to two Dual 6-inputs (DC 63 A for each input) supply power
power to two E9000 chassis + one dual-inputs (1+1 inputs 100 A) + (3+3 inputs 63 A)
E9000 chassis + one dual-inputs (80 A). to two E9000 chassis + one dual-inputs (80 A).
(80 A).
DC PDB 4U DC PDB 4U DC PDB 4U DC PDB 4U
DC PDB 2U DC PDB 2U DC PDB 2U Plastic filler panel 1U
Filler panel 1U Filler panel 1U Filler panel 1U DC PDB 2U
CE-LSW-1 1U CE-LSW-1 1U CE-LSW-1 1U CE-LSW-3 1U
Cabling slot 1U Cabling slot 1U Cabling slot 1U Cabling slot 1U
CE-LSW-0 1U CE-LSW-0 1U CE-LSW-0 1U CE-LSW-2 1U
Cabling slot 1U Cabling slot 1U Cabling slot 1U Cabling slot 1U
CE-LSW-1 1U
  5500-1 2U (disk enclosure)  
Cabling slot 1U
CE-LSW-0 1U
  5500-0 2U (disk enclosure)  
Cabling slot 1U
 
5500-1 2U (controller enclosure) 5500-1 2U (controller enclosure)  
Cabling slot 1U
 
5500-0 2U (controller enclosure) 5500-0 2U (controller enclosure)  
Cabling slot 1U
Filler panel 1U Filler panel 1U Filler panel 1U Filler panel 3U
Filler panel 2U
Cabling slot 1U
E9000-1 12U E9000-1 12U E9000-1 12U 5500-3 2U
5500-2 2U
5500-1 2U
Assembled rail 1U Assembled rail 1U Assembled rail 1U 5500-0 2U
E9000-0 12U E9000-0 12U E9000-0 12U E9000-0 12U
Assembled rail 1U Assembled rail 1U Assembled rail 1U Assembled rail 1U

Only the controller Both controller and disk Disk arrays are deployed Both controller and disk
enclosures are deployed enclosures are deployed. in a separate cabinet. enclosures are deployed.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 64
E9000 Cabinet Layout – N610E-22 AC Cabinets
N610E-22 N610E-22 N610E-22 N610E-22
One cabinet with two chassis One cabinet with two chassis One cabinet with two chassis One cabinet with one chassis
Dual 2-inputs (32 A for each input)
Dual 3-inputs Dual 3-inputs Dual 3-inputs The configuration ratio of disk array controller enclosures to disk
(32 A for each input) (32 A for each input) (32 A for each input) enclosures is 1:1.

AC PDB 3U AC PDB 3U AC PDB 3U


AC PDB 3U
02120437 02120437 02120437
Filler panel 1U Filler panel 1U Filler panel 1U Filler panel 1U
CE6851-3 1U CE6851-3 1U CE6851-3 1U Filler panel 1U
Cabling slot 1U Cabling slot 1U Cabling slot 1U
CE6851-2 1U CE6851-2 1U CE6851-2 1U AC-PDB 3U
Cabling slot 1U Cabling slot 1U Cabling slot 1U
Filler panel 1U Filler panel 1U Filler panel 1U Filler panel 1U
CE-LSW-3 1U
  S5500 V3 disk enclosure-1 2U  
Cabling slot 1U
Cabling slot 1U Cabling slot 1U Cabling slot 1U CE-LSW-2 1U
Filler panel 1U Filler panel 1U Filler panel 1U Cabling slot 1U
 
  S5500 V3 disk enclosure-0 2U  
Cabling slot 1U
Cabling slot 1U Cabling slot 1U Cabling slot 1U  
Cabling slot 1U
S5500 V3 controller enclosure-1 2U S5500 V3 controller enclosure-1 2U  
Filler panel 1U
S5500 V3 controller enclosure-0 2U S5500 V3 controller enclosure-0 2U    
Cabling slot 1U
Filler panel 1U
CE8860 2U
E9000-1 12U E9000-1 12U E9000-1 12U Cabling slot 1U
5500-3 2U
5500-2 2U
5500-1 2U
High-load guide rail 1U High-load guide rail 1U High-load guide rail 1U 5500-0 2U
E9000-0 12U E9000-0 12U E9000-0 12U E9000-0 12U
High-load guide rail 1U High-load guide rail 1U High-load guide rail 1U Assembled rail 1U

Only the controller Both controller and disk Disk arrays are deployed Both controller and disk
enclosures are deployed enclosures are deployed. in a separate cabinet. enclosures are deployed.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 65
E9000 Cabinet Layout – IT Cabinets
2113809 2113809 2113809 2113809

42U IT cabinet 42U IT cabinet 42U IT cabinet 42U IT cabinet

One cabinet with two chassis One cabinet with two chassis One cabinet with two chassis One cabinet with two chassis
1+1 inputs (32 A and AC 380 V for each input)
1+1 inputs (32 A and AC 380 V for each input) 1+1 inputs (32 A and AC 380 V for each input) 1+1 inputs (32 A and AC 380 V for each input)
Apply the same power supply in other scenarios.
Apply the same power supply in other scenarios. Apply the same power supply in other scenarios. Apply the same power supply in other scenarios.

CE6851-1 1U CE6851-1 1U CE6851-3 1U CE6851-3 1U

Cabling slot 1U Cabling slot 1U Cabling slot 1U Cabling slot 1U

CE6851-0 1U CE6851-0 1U CE6851-2 1U CE6851-2 1U

Cabling slot 1U Cabling slot 1U Cabling slot 1U Cabling slot 1U

Filler panel 1U Filler panel 1U Filler panel 1U Filler panel 1U

S5500 V3 disk enclosure-1 2U      

Cabling slot 1U Cabling slot 1U Cabling slot 1U Cabling slot 1U

Filler panel 1U Filler panel 1U Filler panel 1U Filler panel 1U

S5500 V3 disk enclosure-0 2U      

Cabling slot 1U Cabling slot 1U Cabling slot 1U Cabling slot 1U

S5500 V3 controller enclosure-1 2U   S5500 V3 controller enclosure 2U  


S5500 V3 controller enclosure-0 2U   S5500 V3 controller enclosure 2U  
E9000 12U E9000 12U    

Filler panel 1U Filler panel 1U Filler panel 1U Filler panel 1U

E9000 12U E9000 12U E9000 12U E9000 12U

Filler panel 1U Filler panel 1U Filler panel 1U Filler panel 1U

Both controller and disk Disk arrays are deployed Only the controller Disk arrays are deployed
enclosures are deployed. in a separate cabinet. enclosures are deployed in a separate cabinet.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 66
NFVI Port Planning (A Disk Array Contains One Disk
and One Controller Enclosure Respectively or Only
One Controller Enclosure)  A pair of CE6855 switches is connected to four E9000
chassis and four disk arrays. Each disk array can be
11 13 11 13 3 3 17 61 21 65 17 61 21 65 25 29 25 29 DAD 71 83
composed of one disk enclosure and one controller
CE6851HI
7 9 7 9 19 63 23 67 19 63 23 67 27 31 27 31 73 84
enclosure or of only one controller enclosure.
5 5
Disk
array Disk array Ports to Stack
E9000 and FS E9000 storage area Reserved
manage
management area
ment
storage area EOR ports
 Ports in the E9000 and FS management area
a rea 26 30 26 30 83
12 14 12 14 4 4 18 62 22 66 18 62 22 66 DAD 72

28 32 28 32
CE6851HI highlighted on the CE6855 switches are connected to
8 10 8 10 6 6 20 64 24 68 20 64 24 68 74 84

the hardware management ports provided by the


MM910 and NFVI management ports provided by the
switch modules in slots 2X and 3X.
7
9  Ports in the disk array management area highlighted on
33 34 17 18 19 2035 36
41 42 61 62 63 64 43 44
37 38 21 22
23 24 39 40
49 50 65 66 67 68 51 52
the CE6855 switches are connected to the
45 46 47 48 53 54 5556

11 12 13 14 management ports provided by the disk array


8
10 controllers.
 Ports in the E9000 storage area highlighted on the
1E 2X 3X 4E 1E 2X 3X 4E

CE6855 switches are connected to the storage data


25
26 3
25
26 3 ports provided by the E9000.
27 27
4 4
28 28

29 29
5
 Ports in the disk array storage area highlighted on the
30 5 30
31 31 6
32
6
32 CE6855 switches are connected to the storage data
ports provided by the S5500 V3 disk arrays.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 67
NFVI Port Planning (A Disk Array Contains One
Controller Enclosure and Three Disk Enclosures
11 13 11 13 3 17 61 21 65 17 61 21 65 25 29 25 29 DAD 71 83  A pair of CE6855 switches is connected to four E9000
CE6851HI
7 9 7 9 5 19 63 23 67 19 63 23 67 27 31 27 31 73 84 chassis and two disk arrays. Each disk array is
Disk
array Ports
E9000 and FS
manage E9000 storage area
Disk array Reserved to
Stack
ports
composed of one controller and three disk enclosures.
management area storage area EOR
ment
12 14 12 14 a 4rea 18 62 22 66 18 62 22 66 26 30 26 30 DAD 72 83  Ports in the E9000 and FS management area
CE6851HI
8 10 8 10 6 20 64 24 68 20 64 24 68 28 32 28 32 74 84 highlighted on the CE6855 switches are connected to
the hardware management ports provided by the
MM910 and NFVI management ports provided by the
switch modules in slots 2X and 3X.
 Ports in the disk array management area highlighted on
7
9

the CE6855 switches are connected to the


37 38 21 22
33 34 17 18 19 2035 36 23 24 39 40
41 42 61 62 63 6443 44 49 50 65 66 67 68 51 52
45 46 47 48 53 54 5556 management ports provided by the disk array
11 12 13 14
controllers.
8
10  Ports in the E9000 storage area highlighted on the
CE6855 switches are connected to the storage data
1E 2X 3X 4E 1E 2X 3X 4E

ports provided by the E9000.


25 25
3
 Ports in the disk array storage area highlighted on the
26 26
27 27
28 28
4
CE6855 switches are connected to the storage data
29 29
5
30 30
31 31 6
ports provided by the S5500 V3 disk arrays.
32 32

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 68
Service Port Planning When CH121 V3 Blades Are Used
Ports, on EOR switches, for switch stacks as well as north-
south and east-west traffic between VNFs and EOR
switches are planned as illustrated in the figure above.
The number of ports required for east-west traffic as well as
switch stacks is determined by the service traffic volume.
For more details on cable connections, see the network
design document.

The figure below illustrates the ports planned on switch


modules in an E9000 chassis.

Ports for north-south traffic between VNFs and


EOR switches
Ports for east-west traffic between VNFs
and EOR switches
Ports for EOR switch stacks

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 69
Virtual Switching Methods Used by Logical Netw
orks of Management Nodes (CH121 V3)
OVS; NICs are Multiple vNICs share one
bound and work in 40GE physical NIC and
active/standby work in load-sharing mode.
mode.

10G 10G 10G 10G 40G 40G 10G 10G 10G 10G 40G 40G 10G 10G 10G 10G 40G 40G

MEZZ1 MEZZ2 MEZZ1 MEZZ2 MEZZ1 MEZZ2

bond bond bond bond bond bond


Storage_
Storage_
Storage_ data1
data1
data1
OVS OVS OVS OVS OVS OVS
Internal Enternal Internal Enternal Internal Enternal
_base _base _base
Enternal_OM Enternal_OM Enternal_OM
_API _API _API

FS -Control FS -Control FS -Control


FM(M) FM(M)
(in Hos t) (in Hos t) (in Hos t)

Blade Blade

E9000 (FS Domain)


 FusionSphere requires three controllers nodes (FS-Control) and these nodes span on three blades that function as management nodes. Management VNFs, such as the CloudOpera CSM
and U2000, are deployed on the management nodes.
 The Base planes of both management and service nodes use the OVS networking. The eFabric plane of the management nodes uses the OVS networking while that of service nodes use the
SR-IOV networking.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 70
Virtual Switching Methods Used by Logical Networks
of EMS Service Nodes (CH121 V3)
40 40
CX710(1E) CX310(2X) 40 Stack 40 CX310(3X) CX710(4E)
GE GE
GE GE
40 40 40 40 40 10 10 10 10 10 10 10 10 40 40 40 40 40
GE GE GE GE GE GE GE GE GE GE GE GE GE GE GE GE GE GE

NICs are bound Stack


Stack
and work in load-
sharing mode.

eth0 eth1 eth2 eth3 eth0 eth1

10GE 10GE 10GE 10GE 40GE 40GE

MEZZ1 MEZZ2

bond bond

storage_data1
OVS OVS
internal_base OSS_HDFS
OSS_Service N E_LOG
external_om OSS_Self_
ha1
Maintenan
CS ce
VIM
M_b
_API
ase vU2000 vPRS vTSP
F-C CSM vTSP
(ALL (ALL (Worker/Manager/
(in Host) (VNFM ) (Collector)
VMs) VMs) Data)

Blade (CH121 V3)

E9000 (Management Domain)

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 71
SR-IOV Networking Used by Logical Networks of Cl
oudEPC Service Nodes (CH121 V3)
CX710(1E) 40GE CX310(2X) Stack
40GE
CX310(3X) 40GE CX710(4E)
40GE

40GE 40GE 40GE 40GE 40GE 40GE


40GE 40GE 40GE 40GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE

Stack
Stack

Multiple vNICs
share one 40GE
physical NIC.
eth0 eth1 eth2 eth3 eth0 eth1

10GE 10GE 10GE 10GE 40GE 40GE

MEZZ1 MEZZ2 VF
SR-IOV

ha2
bond ha3

storage
_data1 CloudUSN_Fabric_2 CloudUSN_Fabric_2 CloudUSN_OM_2
OVS CloudUSN_Fabric_2 CloudUSN_OM_1
CloudUSN_Fabric_1 CloudUSN_Fabric_1 CloudUSN_Fabric_1
internal external
CloudUSN_Base_2 CloudUSN_Base_2 CloudUSN_Base_2 CloudUSN_Base_2
_base _om CloudEPC_External_2
CloudUSN_Base_1 CloudUSN_Base_1 CloudUSN_Base_1
CloudEPC_External_1 CloudUSN_Base_1

F-C
(in Host)

IPU SPU SDU OMU

Blade1 (CH121 V3)


E9000 (Service Domain)

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 72
EVS Networking Used by Logical Networks of Cl
oudEPC Service Nodes (CH121 V3)

Load-sharing

E9000 (Service Domain)

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 73
Internal Service Flows Between VNF VMs on an S
R-IOV Network (CH121 V3)
 VMs for a VNF communicate with each
10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 40GE 40GE 40GE 40GE
40GE 40GE 40GE 40GE

40GE 40GE

CX710(1E)

40GE
CX310(2X) 40GE 40GE CX310(3X) CX710(4E)
other over the internal vBase and vFabric
40GE

planes. The management traffic is


40GE 40GE 40GE 40GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 40GE 40GE 40GE 40GE

exchanged over the vBase plane and the


signaling and data traffic is exchanged over
the vFabric plane.
 In the SR-IOV networking, traffic between
10GE 10GE 10GE 10GE 40GE 40GE 10GE 10GE 10GE 10GE 40GE 40GE 10GE 10GE 10GE 10GE 40GE 40GE VMs running on the same blade is
VF VF VF
MEZZ1 MEZZ2 MEZZ1 MEZZ2 MEZZ1 MEZZ2

exchanged by the vNICs directly, while


SR-IOV SR-IOV SR-IOV

bond bond bond

OVS
EPC_Base_1
OVS
EPC_Fabric_2
EPC_Fabric_1 EPC_Fabric_2
EPC_OM_2
EPC_OM_1
traffic between VMs running on different
EPC_OM_1 EPC_OM_2 OVS
EPC_Base_2 EPC_Base_2 EPC_Fabric_1 EPC_Base_2 EPC_Fabric_2

blades is exchanged through physical NICs


EPC_Srv_2 EPC_Base_1
EPC_Fabric_1EPC_Fabric_2 EPC_Base_1 EPC_Fabric_1
EPC_Srv_1

and switch modules.


OMU (standby) SDU IPU OMU (standby)
SPU SPU

CH121 V3 CH121 V3 CH121 V3

E9000

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 74
Internal Service Flows Between VNF VMs on an EV
S Network (CH121 V3)
40GE 40GE 40GE 40GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 40GE 40GE 40GE 40GE

40GE 40GE

CX710(1E) CX310(2X) 40GE 40GE CX310(3X) CX710(4E)  VMs for a VNF communicate with each
40GE 40GE
40GE 40GE 40GE 40GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 40GE 40GE 40GE 40GE
other over the internal vBase and vFabric
planes. The management traffic is
exchanged over the vBase plane and the
signaling and data traffic is exchanged
over the vFabric plane.
10GE 10GE 10GE 10GE 40GE 40GE 10GE 10GE 10GE 10GE 40GE 40GE 10GE 10GE 10GE 10GE 40GE 40GE
 In the EVS networking, traffic between
MEZZ1 MEZZ2 MEZZ1 MEZZ2
VMs running on the same blade is
MEZZ1 VF MEZZ2
SR-IOV

bond bond bond


bond bond bond
EVS EVS EVS
EPC_OM_2 exchanged by the EVS directly, while
OVS OVS OVS
EPC_OM
EPC_Fabric

traffic between VMs running on different


EPC_Fabric EPC_Base
EPC_Srv
EPC_Fabric
EPC_Base EPC_OM EPC_Base EPC_Fabric EPC_Base EPC_Base EPC_Fabric

OMU OMU
blades is exchanged through physical
SDU SPU IPU SPU
(standby) (standby)

NICs and switch modules.


CH121 V3 CH121 V3 CH121 V3
E9000

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 75
Service Port Planning When CH121 V5 or CH121H
V3 Blades Are Used
Ports, on EOR switches, for switch stacks as well as north-
south and east-west traffic between VNFs and EOR switches
are planned as illustrated in the figure above.
The number of ports required for east-west traffic as well as
switch stacks is determined by the service traffic volume.
For more details on cable connections, see the network
design document.

The figure below illustrates the ports planned on switch


modules in an E9000 chassis.

Ports for north-south traffic between VNFs and


EOR switches
Ports for east-west traffic between VNFs
and EOR switches
Ports for EOR switch stacks

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 76
Virtual Switching Methods Used by Logical Networks
of Management Nodes (CH121 V5 or CH121H V3)
OVS; NICs are Multiple vNICs share
bound and work one 40GE physical
in active/standby NIC and work in load-
mode. sharing mode.
10G 10G 40G 40G 40G 40G 10G 10G 40G 40G 40G 40G 10G 10G 40G 40G 40G 40G

LOM MEZZ1 MEZZ2 LOM MEZZ1 MEZZ2 LOM MEZZ1 MEZZ2

bond bond bond bond bond bond bond bond bond


Storage_ Storage_
data1 data1
OVS OVS OVS OVS OVS OVS OVS OVS OVS
Internal Internal Internal Enternal
Enternal
_base _base _base
Enternal_OM Enternal Enternal_OM
_API _API _API

FS -Control FS -Control FS -Control


FM(M) e S ight(M) FM(S ) e S ight(S ) (in Hos t)
(in Hos t) (in Hos t)

Blade Blade Blade

E9000 (FS Domain)


 FusionSphere requires three controllers nodes (FS-Control) and these nodes span on three blades that function as management nodes. Management VNFs, such as the CloudOpera CSM and
U2000, are deployed on the management nodes.
 The Base planes of both management and service nodes use the OVS networking. The eFabric plane of the management nodes uses the OVS networking while that of service nodes use the
SR-IOV networking.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 77
Virtual Switching Methods Used by Logical Networks
of EMS Service Nodes (CH121 V5 or CH121H V3)
40GE Stack 40GE
CX710(1E) 40GE
CX920(2X) CX920(3X) 40GE internal_base
CX710(4E)
40GE 40GE
40GE 40GE 40GE 40GE 40GE 10GE 10GE 40GE 40GE 40GE 40GE 10GE 10GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE external_api
Stack
external_om
Stack Stack
NICs are bound
and work in load- storage_data1
sharing mode.
HA
eth0 eth1 eth2 eth3 eth4 eth5

10GE 10GE 40GE 40GE 40GE 40GE OSS_Self_ Maintenance

LOM MEZZ1 MEZZ2 OSS_Service

VNFM_Network_VIM
bond bond
storage_data1
VNFM_Network_Internal
OVS OVS
external_om OSS_Service
internal_ OSS_Self_
base external_api Maintenance
ha VNFM_Network_
Internal

VNFM_Network_VIM

FS-Control CSM U2000


(in Host) (VNFM) (ALL VMs)

Blade (CH121HV3)
E9000 (Management Domain)

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 78
SR-IOV Networking Used by Logical Networks of Clo
udEPC Service Nodes (CH121 V5 or CH121H V3)

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 79
EVS Networking Used by Logical Networks of CloudE
PC Service Nodes (CH121 V5 or CH121H V3)

Load-sharing Load-sharing

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 80
Contents
3. Networking
3.1 E9000 Networking
3.2 2288 Networking
3.3 HP C7000 Networking

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 81
RH2288H V3 or 2288H V5 Physical Networking
The RH2288H V3 or 2288H V5 uses four NICs (one onboard NIC
and three PCIe NICs):
1. Onboard NIC (2 x 10GE): is used to transmit NFVI management
and storage traffic (integration of NFVI management and
storage is recommended in the version) and provides external
ports to connect to the NFVI management and storage TOR
(CE6855).
2. PCIe1 (2 x 10GE): is reserved for storage in NFVI management
and storage separation scenarios and provides external ports to
connect to the storage TOR (CE6855). For example, the NIC is
used at China Mobile and China Unicom sites.
3. PCIe2 (2 x 10GE): is used for service east-west traffic. The
vFabric and vBase traffic of apps is connected to the service
TOR (CE6855) through the external port.
4. PCIe3 (2 x 10GE): is used for service north-south traffic. The
external service port of apps and O&M traffic are connected to
the service TOR (CE6855) through the external port.
5. 2288 hardware management is connected to the TOR (CE5855)
through the management network port.
6. The NFVI management TOR, storage TOR, service TOR, and
device management TOR are connected to the EOR
(CE12804S or CE12808S).

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 82
Virtual Switching Methods Used by Logical Networks
of Management Nodes (RH2288H V3 or 2288H V5)

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 83
Virtual Switching Methods Used by Logical Networks
of EMS Service Nodes (RH2288H V3 or 2288H V5)

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 84
SR-IOV Networking Used by Logical Networks of Cloud
EPC Service Nodes (RH2288H V3 or 2288H V5)

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 85
EVS Networking Used by Logical Networks of CloudEP
C Service Nodes (RH2288H V3 or 2288H V5)

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 86
Contents
3. Networking
3.1 E9000 Networking
3.2 2288 Networking
3.3 HP C7000 Networking

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 87
EVS Topology for the Network Running on HP C
7000 and FusionSphere
S ta c k T O R (N F V I S ta c k
T O R (N F V I
F C S w itc h F C S w itc h T O R (V N F tra ffic ) T O R (V N F tr a ffic )
s to ra g e & m g m t. tr a ffic ) s to ra g e & m g m t. tr a ffic )

4 *8 G E F C 4 *8 G E F C
VNF single Base plane
O A m o d u le _ 1 O A m o d u le _ 2
10G E 10G E 40G E

VNF OM plane
B a y 1 s iw tc h 2 0 G E S ta c k 2 0 G E B a y 2 s w itc h B a y 3 & 4 S w itc h s ta c k B a y 5 & 6 S w itc h s ta c k

20G E 20G E FC 10G E 10G E 10G E 10G E 10G E 10G E 10G E 10G E
ETH ETH ETH FC ETH ETH ETH

VNF single Fabric plane


E a s t-
w est
tra ffic N o rth -

e th 0 FC e th 1 FC
w est
tra ffic
VNF Ext plane
ETH FC ETH FC 10G E 10GE 10G E 10G E

20G E 20G E B a y 2 s w itc h


MEZZ1 M EZ Z2
NFVI management
LOM
and data plane
bond bond bond
NFVI FC storage
OVS
in te r n a l_
EVS EVS data ports
base e x t e r n a l_ a p i
b ase F a b ir c
e x te r n a l_ o m OMA Ext

F -C OMU IP U S PU
(in H o s t)

B la d e ( C H 1 2 1 V 3 )

E 9 0 0 0 ( M a n a g e m e n t D o m a in )

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 88
FC SAN Topology for the Network Running on H
P C7000 and FusionSphere
HP C7000 Blades
Blades
Blades

FL VC FL VC

1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
N N N N N N N N
F F F F F F F F
FC Storage data ports
FC Switch-1 FC Switch-2
GE Management ports

FC FC FC FC GE FC FC FC FC GE
Controller A Controller B
FC SAN

TOR-1: L2 LSW TOR-2: L2 LSW

L2 Fabric

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 89
HP C7000+FusionSphere Networking Diagram
Subrack 1 Subrack 2 Subrack 3

Management Management

Controller A Controller B Controller A Controller B Storage traffic


Service traffic
Controller Controller
Disk enclosure Disk enclosure Aggregation EOR Device management traffic
array 1 array 2
NFVI management traffic
Disk Disk
enclosure enclosure
External network

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 90
Contents

1. CloudEdge Solution Overview


2. NFVI Overview
3. Networking
4. Operation & Alarms
5. Glossary

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 91
Management Operations

Users can perform O&M through the following:


①WebUI ②OSS ③WebUI
1. FusionSphere OpenStack OM web client
Client
2. OSS client: VNF configuration, management, and
FusionSphere
U2000
performance monitoring
Openstack OM
3. VNFM web client: VNF deployment
4. FusionSphere OpenStack web client
Cloud
USN
CloudUG
W
Cloud
CG
VNFM 5. HMM Web of the E9000 management module
6. SSH connections: over which users can log in to
FSP
the MM910 and then proceed to the switch
④WebUI
(FSP Controller) modules.
Storage Storage 7. S5500 V3 disk array web client
Data Management
8. SSH connections: over which users can log in to
⑤WebUI MM910
1E/4E
E9000
OceanStor 5500V3 ⑦WebUI the switch modules.
⑥SSH 2X/3X

⑧SSH CE6851/CE7850/CE12804S

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 92
Alarm Management
Alarms
U2000 VNFM  FusionSphere OpenStack, E9000,
S5500 V3, and CE6851&CE12804S
Alarms Alarms alarms are reported to FusionSphere
FusionSphere OpenStack OM/eSight.
OpenStack OM
Cloude /eSight  FusionSphere OpenStack OM/eSight
CloudUSN CloudUGW CloudCG
PDG
then reports the NFVI alarms to the
FSP VNFM.
Alarms
 The VNFM then reports the NFVI
(FSP Controller) alarms to the U2000.
Alarms
 VNF alarms are reported to the
U2000.

E9000 OceanStor 5500 V3

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 93
Contents

1. CloudEdge Solution Overview


2. NFVI Overview
3. Networking
4. Operation & Alarms
5. Glossary

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 94
Glossary (Solution and Product)

Full Name Acronyms and Abbreviations Description

CloudEdge is the solution name used in both layered cloud and pre-
CloudEdge N/A integration scenarios.

The CloudUSN is a VNF instance that provides the functions of an


SGSN and an MME. The CloudUSN consists of the following
Cloud Unified Service Node CloudUSN components: VNFP, VNRS_VNFC, CSDB_VNFC, CSLB_VNFC, and
USN_VNFC.
The CloudUGW is a VNF instance that provides the functions of a
GGSN, a P-GW, and an S-GW. The CloudUGW consists of the
Cloud Unified Gateway CloudUGW following components: VNFP, VNRS_VNFC, CSDB_VNFC,
CSLB_VNFC, and UGW_VNFC.
The CSM, as a component of the MANO, manages lifecycles of NEs
CloudOpera CSM CSM and has automation capabilities, such as deployment, scale-out, scale-
in, and off-boarding.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 95
Glossary (VNFC, VNF Component)
Full Name Acronyms and Abbreviations Description
The VNFP provides functions including OM proxy, management of
Virtualized Network Function Platform VNFP
virtualized devices, VNFC management, and bus communication.
The VNRS_VNFC is a VNFC instance that provides link layer
Virtualized Network Routing Service VNFC VNRS_VNFC
protocols and routing protocols.

The CSDB_VNFC is a VNFC instance that provides data storage,


Cloud Session Database VNFC CSDB_VNFC
data backup, and data publication for telecommunication services.

The CSLB_VNFC is a VNFC instance that provides a flexible load


Cloud Service Load Balance VNFC CSLB_VNFC
balancing function for telecommunication services.

The USN_VNFC is the core component of the CloudUSN. It is a


Unified Service Node VNFC USN_VNFC
VNFC instance that provides basic protocol processing functions.

The UGW_VNFC is the core component of the CloudUGW. It is a


Unified Gateway VNFC UGW_VNFC
VNFC instance that provides basic data forwarding functions.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 96
Glossary (VDU, Virtualization Deployment Unit)
Full Name Acronyms and Abbreviations Description

Operation Management Unit OMU An OMU is a VM instance and is used to deploy VNFC O&M RUs.

An IPU is a VM instance and is used to deploy VNFC service processing


Interface Process Unit IPU
RUs. An IPU provides virtual network switching capabilities.

An SPU is a VM instance and is used to deploy VNFC interface


Service Process Unit SPU
processing RUs. An SPU provides powerful computing capabilities.

An SDU is a VM instance and is used to deploy CSDB session database


Session Database Unit SDU
RUs. An SDU provides memory space for session data.

An RDU is a VM instance. Similar to an SDU, an RDU is pre-installed


Relational Database Unit RDU
with a relational database.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 97
Questions
 What does the architecture of the layered cloud solution (CloudEdge solution) loo
k like?
 What are the networking differences when the CH121 V3, CH121H V3, or CH121
V5 is used?
 What are the differences between the RH2288H V3+E9000 networking and RH22
88H V5+E9000 networking?

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 98
Conclusion
 The layered cloud solution (CloudEdge solution) using the E9000 or RH2288 is re
commended.

Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 99