Professional Documents
Culture Documents
CloudEdge V100R018C10 Layered Cloud Solution (FusionSphere OpenStack+E9000&2288&HP C7000) - B-V1.0 - OK
CloudEdge V100R018C10 Layered Cloud Solution (FusionSphere OpenStack+E9000&2288&HP C7000) - B-V1.0 - OK
CloudEdge V100R018C10 Layered Cloud Solution (FusionSphere OpenStack+E9000&2288&HP C7000) - B-V1.0 - OK
OpenStack+E9000&2288&HP C700
0)
www.huawei.com
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 3
Contents
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 4
NFV Architecture Overview
Network functions virtualization
orchestrator (NFVO)
OSS/BSS and Orchestrates network services (NSs) and
collaboration layer
• Service and operation
NFVO
NFVO VNF data packets.
(Manage
Performs lifecycle management for NSs.
support (Manage NSNS
Lifecycles)
Manages, authenticates, and authorizes
• Virtualized network Lifecycles)
NFVI resource requests.
function collaboration Manages policies related to NS instances.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 5
NFV Advantages
Now Future
NFV
Software and hardware Products provided by Software and
Layered management and operation multiple vendors on a per hardware
coupling decoupling
layer basis
Automatic scaling
Standardized open
interfaces
Purpose-built hardware Hardware resource sharing COTS
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 6
CloudEdge Solution Overview
MANO: lifecycle management software in NFV mode
U2000
for the Huawei CloudEdge pre-integration solution
Service NE (VNF) MANO FusionSphere OpenStack: a Huawei cloud
management platform that is developed based on the
NFVO OpenStack+KVM architecture. The UVP is Hypervisor
CloudUSN CloudUGW CloudCG in the FusionSphere solution and is KVM-based. The
KVM is the virtual machine based on the Linux Kernel.
VNFM It is a system management program that has been
merged into the Linux kernel. The KVM requires the
Third-party support of virtualized hardware extension processor,
CloudSCEF CloudEPSN app such as the Intel-VT processor, virtualized PPC, and
ARM processor.
E9000: an enterprise-level server that performs the
functions of elastic computing and telecommunication
FusionSphere(UVP) VIM computing. It converges computing, storage, and
network resources to support operator and enterprise
high-end core applications.
E9000 2288 HP C7000 U2000: provides centralized configuration
maintenance, fault management, performance
management, and software management.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 7
CloudEdge Solution Overview
Management zone Service zone
Independent cluster Independent cluster Independent cluster
U2000
APP2
APP1
OMU
VNFM
U2000
OMU
APP2
APP1
OMU
VNFM
SDU
OMU
OMU
SPU
OMU
SDU
SPU
SDU
SPU
SDU
OMU
OMU
SDU
SPU
IPU
SPU
SDU
SPU
SDU
SPU
IPU
SDU
IPU
SPU
IPU
IPU
IPU
IPU
IPU
Fusion
Clusters
HA Mgt HA HA HA
CloudOS
FusionSphere
Storage 5500v3/HP 3PAR 8400
COTS
E9000/2288/HP C7000
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 8
Contents
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 9
Contents
2. NFVI Overview
2.1 FusionSphere OpenStack
2.2 E9000
2.3 2288
2.4 5500 V3
2.5 HP C7000
2.6 Switches
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 10
FusionSphere OpenStack
FusionSphere OpenStack is a Huawei OpenStack platform that
has enhanced functions based on the OpenStack Havana
version. Targeting on enterprise customers, FusionSphere
OpenStack is available for commercial use.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 11
Automatic Discovery and Installation
Large-scale fast installation
Supports plug-and-play.
Automatic software loading and installation; Automatically discovers new X86 servers.
Takes only 80 minutes to complete installation on the
multi-nodes simultaneous installation. first node.
Automatic control over the installation process; Takes only 40 minutes to complete installation on
100 physical servers. KVM/host OS and the
One-click operation. Install
OpenStack are installed from the management
OpenStack software.
Supports simultaneous installation on a maximum of
FusionSphere OpenStack
40 nodes within a L2 network.
Install
service Install
Host OS Wide-range compatibility with mainstream X86
servers
Automatic installation applies to a wide range of
mainstream X86 servers.
Boot from
PXE
...
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 12
WebUI Installation and Cloud Automatic Deployment – Im
proving O&M Efficiency
Controller1 ControllerN Host1 Host2 HostN
Deployment Service
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 13
Unified Alarm Management U2000
1. Quickly detects OpenStack alarms based on the Huawei OpenStack alarm notification
Restful VNFMs only manage
mechanism. corresponding
2. Actively reports alarms for OpenStack faults. VNFM alarms and do not
act as forwarding SNMP alarm
3. Manages Ceilometer-defined alarms. channel. interface
OpenStack
4. Monitors infrastructure (servers, storage devices, or network devices) fault alarms.
Rest interface Rest/SNMP
Alarm interface
FusionSphere Fusion eSight
Manager
HTTP
Infrastruc
ture
Keystone OpenStack OMM
HTTP
service Glance Nova Cinder Neutron Heat
Swift Nova-Compute Cinder-Volume Neutron
Alarm Alarm
Driver Driver Plug-in Ceilometer Management Management
HTTP
Non-
Non-
Virtual VM
VM VM
VM VM
VM Storage Network virtualized
Storage Network
FusionNetwork virtualized
resource FusionCompute FusioSrage
virtualization
virtualization virtualization
virtualization resource
resource
UVP
SNMP
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 14
Contents
2. NFVI Overview
2.1 FusionSphere OpenStack
2.2 E9000
2.3 2288
2.4 5500 V3
2.5 HP C7000
2.6 Switches
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 15
E9000 Appearance
Item Specifications
Color Black
530 mm
Empty weight: 70 kg
Weight
Fully configured: 220 kg
220 V AC
Rated input voltage
48 V DC
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 16
E9000 Front View
CH121/CH140 CH240/CH242/CH242 V3 CH220/CH221/CH222
1 1
8 6 8 6
1 1
7 5 7 5
1 1
6 6
4
1 4
1
5 5
3 3
1 1
4 4
2 2
1 1
3 1 3 1
1 1
2 2
0 0
1 9 1 9
Half-width slot number Full-width slot number (1) Full-width slot number (2)
Eight full-width or sixteen half-width compute nodes can be installed in front slots.
Numbering rules for slots of full-width compute nodes based on compute node types are as follows:
Slot numbers of the CH240, CH242, CH242 V3 in ascending order: 1–8. The CH24X series is not recommended.
Slot numbers of the CH220, CH221, CH222 in ascending order: 9–16. Full-width compute nodes of the CH220, CH221 and
CH222 are expanded from half-width compute nodes of the CH121. The CH222 V3 is used as the management node FS. Half-
width slots use CH121 V3, CH121H V3, or CH121 V5.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 17
E9000 Rear View
1E 2X 3X 4E
1 1 Identifier Description
3 4 1
6 6
3 2 Supports 2 management modules
1MM/2MM
2MM working in active/standby mode.
5 11
1 7
Fan module Fan module Supports 14 fan modules.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 18
Half-Width CH121 V3 Compute Node
Item Half-Width 2P Blade Server with One Slot
Front view
Number of
1 or 2
processors
Processor
Intel Xeon E5-2600 v3 series (core option: 4, 6, and 8)
type
Number of
Two 2.5-inch SSDs, SAS disks, or SATA disks
hard disks
Axial view
2 SATA DOMs
Mezz Card Onboard 2 Micro SDs (RAID 1) which can be removed or inserted without
storage opening the cover
1 USB flash drive (USB3.0)
Supported
RAID 0 and 1 (LSISAS2308 RAID card)
RAIDs
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 19
Half-Width CH121H V3 Compute Node
Front view Item Half-Width 2P Blade Server with One Slot
Number of processors 1 or 2
Number of hard disks 2 x 2.5-inch HDD (SAS or SATA) or NVMe SSD disks
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 20
Half-Width CH121 V5 Compute Node
Front view
Item Half-Width 2P Blade Server with One Slot
Number of processors 1 or 2
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 21
Comparison Between CH121 V3, CH121H V3,
and CH121 V5
CH121 V5 CH121H V3 CH121 V3
Half-width 2P blade server with one slot
Item Half-width 2P blade server with one slot Half-width 2P blade server with one slot
Processor type Intel Xeon Gold v5 series Intel Xeon E5-2600 v4 series Intel Xeon E5-2600 v3 series
Number of
2 2 2
processors
24 DDR4 DIMM slots with a maximum 24 DDR4 DIMM slots with a maximum 24 DDR4 DIMM slots with a maximum memory of
Memory slot memory of 1.5 TB memory of 1.5 TB 1.5 TB
Number of hard 2 x 2.5-inch HDD (SAS or SATA) or NVMe 2 x 2.5-inch HDD (SAS or SATA) or SSD 2 x 2.5-inch HDD (SAS or SATA) or SSD (SAS or
disks SSD disks (SAS or SATA) disks SATA) disks
Supported RAIDs RAID 0 and RAID 1 RAID 0 and RAID 1 RAID 0 and RAID 1
Supports expanding two mezz cards. Supports expanding two mezz cards. Supports expanding two mezz cards.
PCIe expansion
Supports expanding one FPGA card. Supports expanding one FPGA card. Supports expanding one PCIe standard card.
LOM 2 x 10GE 2 x 10GE N/A
2 SATA DOM
2 SATA DOM 2 SATA DOMs
2 Micro SDs (RAID 1)
Onboard storage 2 Micro SDs (RAID 1) 2 Micro SDs (RAID 1)
1 USB flash drive (USB3.0)
1 USB flash drive (USB3.0) 1 USB flash drive (USB3.0)
Dimensions 60.46 mm x 210 mm x 537.2 mm 60.46 mm x 210 mm x 537.2 mm 60.46 mm x 210 mm x 537.2 mm
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 22
LOM on CH121H V3 or CH121 V5
Comparing with CH121 V3, CH121H V3 and CH121 V5 are equipped with a LOM, which works together with the
switch boards to provide a 10 GE plane.
Backplane
Backplane Backplane
1E 1E 1E
MEZZ1 Mezz 1 Mezz 1
LOM LOM
3X
X722 82599 3X
3X
4E
4E
4E
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 23
CX310: 10GE Converged Switch Module CX310 Logical Architecture
Panel
Backplane
CX310
Downlink:
Serial 16 x (2 x 10GE) 10GE Uplink:
port Switch 16 x 10GE
Chip
Stacking over
the backplane:
Ethernet optical module: 1 x 40GE
SFP+ 10 Gbit/s: Used by a 10GE port;
single-mode or multimode LC fiber ports
SFP 1 Gbit/s: Used by a GE port; 10GE Ethernet L2/L3 switching:
single-mode or multimode LC fiber ports
Supports 16 10GE ports in the uplink.
16 x Supports 32 10GE ports in the downlink (two for each half-
Ethernet RJ45 electrical interface module:
10GE Used by a GE port; 1000 Base-T width slot)
SFP+ RJ45 twisted pair ports Stackable:
port • Provides one 40GE port for module stacking over the
backplane.
DAC cable: Used by a 10GE port; • If you need a larger stacking bandwidth, you can add
Provided with interface modules;
Length: 1 m, 3 m, 5 m, 7 m, or 10 m stacking connections by using ports on the panel.
• Supports a maximum of four internal stacking switch
modules.
Note: The preceding modules and cables can be Supports L2/L3 switching.
deployed on the SFP+ ports at the same time.
Converged switching:
Supports DCB (PFC, ETS, DCBX) and TRILL.
Supports FIP Snooping Bridge (FSB).
The two CX310s in a pair of slots can implement independent
switching, work in 1+1 redundancy mode, or work in load sharing
mode by working with the operating system (OS) and network
interface cards (NICs).
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 24
CX710: 40GE Converged Switch Module
Uplink
8 x 40GE
6 of them can be each divided into four 10GE
ports.
Downlink
STAT 16 x 40GE
Backplane
with 10GE mezz card.
Backplane direct links
2 x 40GE (can be used to stack devices or as
interconnection channels)
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 25
CX920: Multi-Plane Switch Module
The CX920 switch module (referred to as CX920) is the switching control unit that provides data
switching for server blades and provides external service and management ports in a centralized manner.
The 10GE and 40GE switching planes are physically isolated from each other and work independently.
The 10GE switching plane connects to the LOMs of blades (Currently only the CH121H V3 server
supports LOMs). The 40GE switching plane connects to mezzanine card 1 or 2 of blades.
The CX920s are installed in the rear slots of the E9000 chassis. They are installed in slots 2X and 3X. If
they are installed in slots 1E and 4E, the 10GE switching plane is unavailable. Through the E9000
chassis backplane, the CX920s are connected to the compute nodes, storage nodes, and management
modules to implement switching for internal data packets and management packets, providing high-
speed data transmission for users.
The CX920 logical architecture consists of four modules: baseboard management controller (BMC)
module, CPU system module, 10GE switch module, and 40GE switch module, as shown in the figure on
the left. The BMC powers on and off nodes and modules, monitors the system, and upgrades
components.
The CPU system module is the controlling core for the CX920. It processes network protocol packets and
manages user configuration.
The 10GE and 40GE switch modules are the data processing core of the CX920. They forward data
between internal data processing modules and external network devices.
Uplink: 8 x 40GE + 8 x 10GE
Downlink: 16 x 40GE + 16 x 10GE
Backplane direct links
2 x 40GE (40GE switching plane) + 1 x 40GE (10GE switching plane)
Mezz card type: MZ710 and LOM
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 26
Contents
2. NFVI Overview
2.1 FusionSphere OpenStack
2.2 E9000
2.3 2288
2.4 5500 V3
2.5 HP C7000
2.6 Switches
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 27
2288 Appearance
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 28
Front Panel of the RH2288H V3 with 25 2.5-
Inch Hard Disks
9 Network port link status indicator 3 10 Network port link status indicator 2
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 29
Rear Panel of the RH2288H V3
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 30
Front Panel of the 2288H V5 with 25 2.5-
Inch Hard Disks
5 Power button/indicator – –
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 31
Front Panel of the 2288H V5
Or
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 32
RH2288H V3 and 2288H V5 Specifications Comparison
Type Sub-category RH2288H V3 2288H V5
Chassis N/A N610E-22 N610E-22
Model RH2288H V3 (25 hard disk chassis EXP) H22H-03 2288H V5 (25 hard disk chassis EXP) H22H-05
Management Onboard NIC 2 x 10GE optical ports (82599). The NIC is used for NFVI management and storage. 2 x 10GE optical ports. The NIC is used for NFVI management and storage.
server
Extended NIC 1 SP310 (Intel 82599 2 x 10GE). The NIC is used for services. SP330 (IntelX710 2 x 10GE). The NIC is used for services.
Model RH2288H V3 (25 hard disk chassis EXP) H22H-03 2288H V5 (25 hard disk chassis EXP) H22H-05
CPU 2 x E5-2658A V3 (Haswell-EP 12 cores)/2 x E5-2658 V4 (Broadwell-14 cores) 2 x 5120 TB (14 cores, recommended)
Hard disk 2 x 600 GB SAS, 2.5. rear disk 2 x 600 GB SAS, 2.5. rear disk
Onboard NIC 2 x 10GE optical ports (82599). The NIC is used for NFVI management and storage. 2 x 10GE optical ports. The NIC is used for NFVI management and storage.
Service server
Extended NIC 1 SP310 (Intel 82599 2 x 10GE). The NIC is used for services. SP330 (IntelX710 2 x 10GE). The NIC is used for services.
Extended NIC 2 SP310 (Intel 82599 2 x 10GE). The NIC is used for services. SP330 (IntelX710 2 x 10GE). The NIC is used for services.
For delivery outside China, the TPM (Infineon chip) is delivered. For delivery in China, the
TPM N/A
TPM is not delivered.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 33
Contents
2. NFVI Overview
2.1 FusionSphere OpenStack
2.2 E9000
2.3 2288
2.4 5500 V3
2.5 HP C7000
2.6 Switches
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 34
5500 V3 Overview
The OceanStor V3 series uses a new Pangea V2R1C00/C01 hardware platform.
5500 V3: disk and controller integration (2U)
5500 V3
Name Description
Processor (single controller) One 6-core processor
Cache capacity (single controller) 48 GB or 128 GB
Max. number of controllers per subrack 2
2U SAS enclosure,
Disk enclosure type supporting 25 2.5-inch
disks
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 35
5500 V3 Controller Enclosure with 25 Disk Slots
Icon Description on the Left Icon Icon Description on the Disk Unit Icon Description on the Right Mounting
Icon Icon
Mounting Ear Ear
1. Disk powered off: off
Disk slot label (The 2. Disk working properly: steady on green Enclosure ID indicator
left figure indicates (when the disk is powered on and
that the controller performs data reading and writing) Enclosure location indicator
enclosure supports 3. Disk alarms reported: steady on red 1. Enclosure not being located: off
25 disk slots.) 4. Disk to be invalid: blinking red (0.5 Hz) 2. Enclosure being located: blinking
5. Disk being located: blinking blue (2 Hz) blue (2 Hz)
Wi-Fi button
(reserved but not Enclosure alarm indicator
supported) Disk type label 1. No alarm reported: off
2. Alarms reported: steady on red
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 36
Ports on the Rear Panel of the 5500 V3
Serial port
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 37
2U 2.5-Inch Disk Enclosure
Supports 6G SAS/NL-
Expansion module
Dual-expansion board
uplink/downlink
600 W PSU
Supports the 1+1 redundancy
1 2 3 mode.
Integrates the fan of the disk
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 38
Contents
2. NFVI Overview
2.1 FusionSphere OpenStack
2.2 E9000
2.3 2288
2.4 5500 V3
2.5 HP C7000
2.6 Switches
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 39
HP Blade System C7000 Enclosure
Industry-leading blade density
Hosts up to 16 half-width or 8 full-width blades
8 interconnect modules
GE and 10GE
4Gb SAN, iSCSI
Infiniband interconnects
10U Pass-thru module
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 40
HP C7000 BL460C Gen9 (Half Width)
Item Half-width blade server
Number of processors 1 or 2
Internal View
1. FlexibleLOM adapter
2. Nand Flash & Micro SD
3. Mezzanine Slots (x16 PCI 3.0) Connector
4. Sixteen (16) DDR4 DIMM slots (8 per processor)
5. Up to two (2) Intel? Xeon? E5-2600 v3 or v4 family processors
6. HPE BLc 12W Smart Storage Battery connector
7. USB 3.0 and TPM
8. Embedded SATA Connector
9. Solid State Device
10. Two hot-plug drive bays
11. HPE Smart Array P244br Controller with 1GB FBWC
12. iLO Management Engine
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 41
HP BLc VC FlexFabric-20/40 F8
Features:
16 x 10/20Gb Ethernet downlinks to server blade NICs and
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 42
HP 6125XLG Ethernet Blade Switch
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 43
Adapter for HP BL460C Gen9
Mixed Storage - supports NIC + FCoE on one port, and NIC + iSCSI
on the other
HPE FlexFabric Virtual Connect
20Gb 2-port 650FLB Adapter 20Gb 2-port FlexFabric-20/40 F8
650FLB Adapter Concurrent Storage - concurrently supports NIC, FCoE, and iSCSI Module
storage functions on the same port (NIC + FCoE + iSCSI)
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 44
HP BL460C Gen9 Onboard Ports Connections
HP C7000 BL460C Gen9 supports LOMs. (If FC SAN is used, 650FLB is recommended.)
BL460C Gen9 has to mezz slots for expansion.
The backplane hosts up to eight half-width switch modules.
The example configuration here includes one 650FLB LOM, two 560M mezz cards, and six half-width switch modules.
Connections between BL460C Gen9 mezz
slots and switch modules
LOM
Backplane
Bay1 Bay2 Port 1 connects to Bay 1. Port 2 connects to Bay 2. Bay
LOM
650FLB
1 and Bay 2 can be stacked.
Mezz 1 (560M)
Bay3 Bay4 Port 1 connects to Bay 3. Port 2 connects to Bay 4.
Bay 3 and Bay 4 can be stacked.
MEZZ1
560M
Mezz 2 (560M)
Bay5 Bay6 Port 1 connects to Bay 5. Port 2 connects to Bay 6. Bay
5 and Bay 6 can be stacked.
MEZZ2
560M
Mezz 2 (with 4 ports)
Bay7 Bay8 Ports 3 and 4 connect to Bay 7 and Bay 8. However, Bay
7 and Bay 8 are not used in CloudEdge.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 45
Contents
2. NFVI Overview
2.1 FusionSphere OpenStack
2.2 E9000
2.3 2288
2.4 5500 V3
2.5 HP C7000
2.6 HP 3PAR 8000
2.7 Switches
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 46
HPE 3PAR StoreServ 8000 Storage
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 47
Contents
2. NFVI Overview
2.1 FusionSphere OpenStack
2.2 E9000
2.3 2288
2.4 5500 V3
2.5 HP C7000
2.6 HP 3PAR 8000
2.7 Switches
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 48
CE6855HI
Left side
Right side
In standard configurations, the CE6855HI is a TOR for CloudEdge V100R018C10 and can be used as an EOR
in small-capacity scenarios.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 49
CE6855HI (Cont.)
Power supply slot 1 Power supply slot 2
Applicable power modules: Applicable power modules:
1 350 W DC power module
2 350 W DC power module
Forty-eight 10GE SFP+ Ethernet optical ports Six 40GE QSFP+ Ethernet optical ports
Applicable transceiver modules and cables: Note:
10GE optical module (OSXD22N00 and LE2MXSC80FF0 not supported) A 40GE QSFP+ port can be split into four 10GE ports.
10GE-CWDM optical module Applicable modules and cables:
9 GE optical module 10 40GE optical module
GE copper transceiver module (only working at 1000 Mbit/s) 1 m, 3 m, and 5 m QSFP+ copper cables (QSFP+ to 4*SFP+)
3 m, 10 m, and 20 m SFP+ AOC cables 1 m, 3 m, and 5 m QSFP+ copper cables (QSFP+ to QSFP+)
11 Three port-side mounting holes for mounting brackets 12 Four power-supply-side mounting holes for mounting brackets
13 Ground screw - -
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 50
CE6851HI
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 51
CE6851HI (Cont.)
Power supply slot 1 Power supply slot 2
Applicable power modules: Applicable power modules:
1 350 W DC power module
2 350 W DC power module
Forty-eight 10GE SFP+ Ethernet optical ports Six 40GE QSFP+ Ethernet optical ports
Applicable transceiver modules and cables: Note:
10GE optical module (OSXD22N00 and LE2MXSC80FF0 not supported) A 40GE QSFP+ port can be split into four 10GE ports.
10GE-CWDM optical module Applicable modules and cables:
9 GE optical module 10 40GE optical module
GE copper transceiver module (only working at 1000 Mbit/s) 1 m, 3 m, and 5 m QSFP+ copper cables (QSFP+ to 4*SFP+)
3 m, 10 m, and 20 m SFP+ AOC cables 1 m, 3 m, and 5 m QSFP+ copper cables (QSFP+ to QSFP+)
11 Three port-side mounting holes for mounting brackets 12 Four power-supply-side mounting holes for mounting brackets
13 Ground screw - -
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 52
CE7850
The CE7850 can function as the EOR in the CloudEdge solution for Telekom Austria (currently, the CE7850
is not included in the standard configurations).
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 53
CE7850 (Cont.)
ESN label
7 Note: This label is drawable, and you can pull it outward to view the 8 USB port
ESN and MAC address of the switch.
11 Four middle mounting holes for mounting brackets 12 Four power-supply-side mounting holes for mounting brackets
13 Ground screw - -
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 54
CE12804S
1. Two MPUs
2. Four interface
boards
3. Two switching
boards
The CE12804S is used as the EOR of the CloudEdge. It applies to all current CloudEdge versions.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 55
CE12804S (Cont.)
Slot Type Slot ID Module Supported Remarks
E line cards:
CE-L24LQ-EC1 24*40G
CE-L48XS-EC 48*10G
CE-L04CF-EF 4*100G
The cards match blades of class C.
LPU slots Slot 1 to slot 4 LPUs provide GE, 10GE, 40GE and 100GE ports.
F line cards:
CE-L48XS-FD/FDA 48*10G
CE-L36LQ-FD 36*40G
CE-L12CQ-FD 12*100G
The cards match blades of class F.
MPU slots Slot 5 to slot 6 CE-MPUA-S MPUs work in 1:1 hot backup mode.
SFUs complete switching of service data in the entire system and work in
SFU slots Slot 7 to slot 8 2 CE-SFU-S cards
load balancing and redundancy mode.
The AC&high-voltage DC chassis can support a maximum of four 3000 W
AC&high-voltage DC chassis: 3000 W AC&high-voltage DC power modules. The DC chassis does not support
Power module
PM1 to PM4 AC&high-voltage DC power module such a power module.
slots
DC chassis: 2200 W DC power module 2200 W DC power module: –48 V DC/–60 V DC input; 48.5 V DC/2200 W
output
Fan module slots FAN1 to FAN3 FAN-600A-B fan module Standard configuration: 3
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 56
CE12808S
Front Rear
1. Two MPUs
2. Eight interface boards
3. Four switching boards
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 57
CE12808S (Cont.)
Slot Type Slot ID Module Supported Remarks
LPU slots Slot 1 to Slot 8 E line cards: LPUs provide GE, 10GE, 40GE and 100GE ports.
CE-L24LQ-EC1 24*40G
CE-L48XS-EC 48*10G
CE-L04CF-EF 4*100G
The cards match blades of class C.
F line cards:
CE-L48XS-FD/FDA 48*10G
CE-L36LQ-FD 36*40G
CE-L12CQ-FD 12*100G
The cards match blades of class F.
MPU slots Slot 9 to Slot 10 CE-MPUA-S MPUs work in 1:1 hot backup mode.
Slot 11 to Slot 14 4 CE-SFU-S cards SFUs complete switching of service data in the entire
SFU slots system and work in load balancing and redundancy
mode.
PM1 to PM8 AC&high-voltage DC chassis: 3000 W The AC&high-voltage DC chassis can support a
AC&high-voltage DC power module maximum of eight 3000 W AC&high-voltage DC
Power module DC chassis: 2200 W DC power module power modules. The DC chassis does not support
slots such a power module.
2200 W DC power module: –48 V DC/–60 V DC
input; 48.5 V DC/2200 W output
Fan module slots FAN1 to FAN6 FAN-600A-B fan module Standard configuration: 6
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 58
Contents
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 59
Contents
3. Networking
3.1 E9000 Networking
3.2 2288 Networking
3.3 HP C7000 Networking
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 60
E9000 Physical Networking
E9000 E9000
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 61
E9000 Cable Connections When CH121 V3 Blades Ar
e Used
External
ports for
External ports for External ports for service External ports for
service
mgmt. traffic and OM traffic management traffic
and OM
traffic
EOR EOR
40GE 40GE
40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE
40GE 40GE 40GE 40GE
Stack
5500 V3 5500 V3
Controller A Controller B Controller A Controller B External ports for
storage&mgmt. traffic
GE 10GE 10GE 10GE 10GE GE 10GE 10GE 10GE 10GE GE 10GE 10GE 10GE 10GE GE 10GE 10GE 10GE 10GE
Ports for GE
10GE 10GE 10GE 10GE GE
10GE 10GE 10GE 10GE 40GE
GE
10GE 10GE 10GE 10GE GE 10GE 10GE 10GE 10GE Ports for
40GE
hardware hardware
management CE6851-1 Ports for NFVI management traffic Ports for storage data Ports for storage data Ports for NFVI management traffic CE6851-2 management
10GE 10GE 10GE 10GE 10GE 40GE 40GE 10GE 10GE 10GE 10GE 10GE
GE GE
Stack
GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 40GE 40GE 40GE 40GE 40GE 40GE GE
40GE 40GE 40GE 40GE 40GE 40GE
40GE
40GE
MM910- 1 CX710(1E) CX310(2X) 40GE 40GE CX310(3X) CX710(4E) MM910- 2
Stack
40GE 40GE
40GE 40GE 40GE 40GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 40GE 40GE 40GE 40GE
Stack Stack
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 62
E9000 Cable Connections When CH121 V5 or CH121
H V3 Blades Are Used
Router(Customer)-1 Router(Customer)-2
10GE 10GE 10GE/100 10GE/100 10GE/100 10GE/100
10GE 10GE
GE GE GE GE
External
External ports External ports for service
ports for
for mgmt. traffic and OM traffic External ports for
service
management traffic
and OM
traffic
CE12804S/CE8860 CE12804S/CE8860
40GE 40GE
40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE
40GE 40GE Stack 40GE 40GE
5500 V3 5500 V3
Controller A Controller B Controller A Controller B External ports for
storage&mgmt.traffic
GE 10GE 10GE GE 10GE 10GE GE 10GE 10GE GE 10GE 10GE
GE GE GE GE
10GE 10GE 10GE 10GE 40GE 10GE 10GE 10GE 10GE
40GE
Ports for hardware Ports for NFVI
management traffic CE6851-1 management traffic Ports for storage data Ports for storage data Ports for NFVI management traffic CE6851-2
10GE 10GE 10GE 10GE 10GE 40GE 40GE 10GE 10GE 10GE 10GE 10GE
GE GE
Stack
GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 40GE 40GE 40GE 40GE 40GE 40GE GE
40GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE
40GE 40GE
40GE
MM910- 1 CX710(1E) CX920(2X) Stack 40GE CX920(3X) CX710(4E) MM910- 2
40GE
40GE
40GE 40GE 40GE 10GE 10GE 40GE 40GE 40GE 40GE 10GE 10GE 40GE 40GE 40GE
Stack Stack
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 63
E9000 Cabinet Layout – N610E-22 DC Cabinets
N610E-22 N610E-22 N610E-22 N610E-22
One cabinet with two chassis One cabinet with two chassis One cabinet with two chassis One cabinet with one chassis
Dual 6-inputs (DC 63 A for each input) supply
Dual 6-inputs (DC 63 A for each input) supply power to two Dual 6-inputs (DC 63 A for each input) supply power
power to two E9000 chassis + one dual-inputs (1+1 inputs 100 A) + (3+3 inputs 63 A)
E9000 chassis + one dual-inputs (80 A). to two E9000 chassis + one dual-inputs (80 A).
(80 A).
DC PDB 4U DC PDB 4U DC PDB 4U DC PDB 4U
DC PDB 2U DC PDB 2U DC PDB 2U Plastic filler panel 1U
Filler panel 1U Filler panel 1U Filler panel 1U DC PDB 2U
CE-LSW-1 1U CE-LSW-1 1U CE-LSW-1 1U CE-LSW-3 1U
Cabling slot 1U Cabling slot 1U Cabling slot 1U Cabling slot 1U
CE-LSW-0 1U CE-LSW-0 1U CE-LSW-0 1U CE-LSW-2 1U
Cabling slot 1U Cabling slot 1U Cabling slot 1U Cabling slot 1U
CE-LSW-1 1U
5500-1 2U (disk enclosure)
Cabling slot 1U
CE-LSW-0 1U
5500-0 2U (disk enclosure)
Cabling slot 1U
5500-1 2U (controller enclosure) 5500-1 2U (controller enclosure)
Cabling slot 1U
5500-0 2U (controller enclosure) 5500-0 2U (controller enclosure)
Cabling slot 1U
Filler panel 1U Filler panel 1U Filler panel 1U Filler panel 3U
Filler panel 2U
Cabling slot 1U
E9000-1 12U E9000-1 12U E9000-1 12U 5500-3 2U
5500-2 2U
5500-1 2U
Assembled rail 1U Assembled rail 1U Assembled rail 1U 5500-0 2U
E9000-0 12U E9000-0 12U E9000-0 12U E9000-0 12U
Assembled rail 1U Assembled rail 1U Assembled rail 1U Assembled rail 1U
Only the controller Both controller and disk Disk arrays are deployed Both controller and disk
enclosures are deployed enclosures are deployed. in a separate cabinet. enclosures are deployed.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 64
E9000 Cabinet Layout – N610E-22 AC Cabinets
N610E-22 N610E-22 N610E-22 N610E-22
One cabinet with two chassis One cabinet with two chassis One cabinet with two chassis One cabinet with one chassis
Dual 2-inputs (32 A for each input)
Dual 3-inputs Dual 3-inputs Dual 3-inputs The configuration ratio of disk array controller enclosures to disk
(32 A for each input) (32 A for each input) (32 A for each input) enclosures is 1:1.
Only the controller Both controller and disk Disk arrays are deployed Both controller and disk
enclosures are deployed enclosures are deployed. in a separate cabinet. enclosures are deployed.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 65
E9000 Cabinet Layout – IT Cabinets
2113809 2113809 2113809 2113809
One cabinet with two chassis One cabinet with two chassis One cabinet with two chassis One cabinet with two chassis
1+1 inputs (32 A and AC 380 V for each input)
1+1 inputs (32 A and AC 380 V for each input) 1+1 inputs (32 A and AC 380 V for each input) 1+1 inputs (32 A and AC 380 V for each input)
Apply the same power supply in other scenarios.
Apply the same power supply in other scenarios. Apply the same power supply in other scenarios. Apply the same power supply in other scenarios.
Both controller and disk Disk arrays are deployed Only the controller Disk arrays are deployed
enclosures are deployed. in a separate cabinet. enclosures are deployed in a separate cabinet.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 66
NFVI Port Planning (A Disk Array Contains One Disk
and One Controller Enclosure Respectively or Only
One Controller Enclosure) A pair of CE6855 switches is connected to four E9000
chassis and four disk arrays. Each disk array can be
11 13 11 13 3 3 17 61 21 65 17 61 21 65 25 29 25 29 DAD 71 83
composed of one disk enclosure and one controller
CE6851HI
7 9 7 9 19 63 23 67 19 63 23 67 27 31 27 31 73 84
enclosure or of only one controller enclosure.
5 5
Disk
array Disk array Ports to Stack
E9000 and FS E9000 storage area Reserved
manage
management area
ment
storage area EOR ports
Ports in the E9000 and FS management area
a rea 26 30 26 30 83
12 14 12 14 4 4 18 62 22 66 18 62 22 66 DAD 72
28 32 28 32
CE6851HI highlighted on the CE6855 switches are connected to
8 10 8 10 6 6 20 64 24 68 20 64 24 68 74 84
29 29
5
Ports in the disk array storage area highlighted on the
30 5 30
31 31 6
32
6
32 CE6855 switches are connected to the storage data
ports provided by the S5500 V3 disk arrays.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 67
NFVI Port Planning (A Disk Array Contains One
Controller Enclosure and Three Disk Enclosures
11 13 11 13 3 17 61 21 65 17 61 21 65 25 29 25 29 DAD 71 83 A pair of CE6855 switches is connected to four E9000
CE6851HI
7 9 7 9 5 19 63 23 67 19 63 23 67 27 31 27 31 73 84 chassis and two disk arrays. Each disk array is
Disk
array Ports
E9000 and FS
manage E9000 storage area
Disk array Reserved to
Stack
ports
composed of one controller and three disk enclosures.
management area storage area EOR
ment
12 14 12 14 a 4rea 18 62 22 66 18 62 22 66 26 30 26 30 DAD 72 83 Ports in the E9000 and FS management area
CE6851HI
8 10 8 10 6 20 64 24 68 20 64 24 68 28 32 28 32 74 84 highlighted on the CE6855 switches are connected to
the hardware management ports provided by the
MM910 and NFVI management ports provided by the
switch modules in slots 2X and 3X.
Ports in the disk array management area highlighted on
7
9
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 68
Service Port Planning When CH121 V3 Blades Are Used
Ports, on EOR switches, for switch stacks as well as north-
south and east-west traffic between VNFs and EOR
switches are planned as illustrated in the figure above.
The number of ports required for east-west traffic as well as
switch stacks is determined by the service traffic volume.
For more details on cable connections, see the network
design document.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 69
Virtual Switching Methods Used by Logical Netw
orks of Management Nodes (CH121 V3)
OVS; NICs are Multiple vNICs share one
bound and work in 40GE physical NIC and
active/standby work in load-sharing mode.
mode.
10G 10G 10G 10G 40G 40G 10G 10G 10G 10G 40G 40G 10G 10G 10G 10G 40G 40G
Blade Blade
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 70
Virtual Switching Methods Used by Logical Networks
of EMS Service Nodes (CH121 V3)
40 40
CX710(1E) CX310(2X) 40 Stack 40 CX310(3X) CX710(4E)
GE GE
GE GE
40 40 40 40 40 10 10 10 10 10 10 10 10 40 40 40 40 40
GE GE GE GE GE GE GE GE GE GE GE GE GE GE GE GE GE GE
MEZZ1 MEZZ2
bond bond
storage_data1
OVS OVS
internal_base OSS_HDFS
OSS_Service N E_LOG
external_om OSS_Self_
ha1
Maintenan
CS ce
VIM
M_b
_API
ase vU2000 vPRS vTSP
F-C CSM vTSP
(ALL (ALL (Worker/Manager/
(in Host) (VNFM ) (Collector)
VMs) VMs) Data)
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 71
SR-IOV Networking Used by Logical Networks of Cl
oudEPC Service Nodes (CH121 V3)
CX710(1E) 40GE CX310(2X) Stack
40GE
CX310(3X) 40GE CX710(4E)
40GE
Stack
Stack
Multiple vNICs
share one 40GE
physical NIC.
eth0 eth1 eth2 eth3 eth0 eth1
MEZZ1 MEZZ2 VF
SR-IOV
ha2
bond ha3
storage
_data1 CloudUSN_Fabric_2 CloudUSN_Fabric_2 CloudUSN_OM_2
OVS CloudUSN_Fabric_2 CloudUSN_OM_1
CloudUSN_Fabric_1 CloudUSN_Fabric_1 CloudUSN_Fabric_1
internal external
CloudUSN_Base_2 CloudUSN_Base_2 CloudUSN_Base_2 CloudUSN_Base_2
_base _om CloudEPC_External_2
CloudUSN_Base_1 CloudUSN_Base_1 CloudUSN_Base_1
CloudEPC_External_1 CloudUSN_Base_1
F-C
(in Host)
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 72
EVS Networking Used by Logical Networks of Cl
oudEPC Service Nodes (CH121 V3)
Load-sharing
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 73
Internal Service Flows Between VNF VMs on an S
R-IOV Network (CH121 V3)
VMs for a VNF communicate with each
10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 40GE 40GE 40GE 40GE
40GE 40GE 40GE 40GE
40GE 40GE
CX710(1E)
40GE
CX310(2X) 40GE 40GE CX310(3X) CX710(4E)
other over the internal vBase and vFabric
40GE
OVS
EPC_Base_1
OVS
EPC_Fabric_2
EPC_Fabric_1 EPC_Fabric_2
EPC_OM_2
EPC_OM_1
traffic between VMs running on different
EPC_OM_1 EPC_OM_2 OVS
EPC_Base_2 EPC_Base_2 EPC_Fabric_1 EPC_Base_2 EPC_Fabric_2
E9000
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 74
Internal Service Flows Between VNF VMs on an EV
S Network (CH121 V3)
40GE 40GE 40GE 40GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 40GE 40GE 40GE 40GE
40GE 40GE
CX710(1E) CX310(2X) 40GE 40GE CX310(3X) CX710(4E) VMs for a VNF communicate with each
40GE 40GE
40GE 40GE 40GE 40GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 10GE 40GE 40GE 40GE 40GE
other over the internal vBase and vFabric
planes. The management traffic is
exchanged over the vBase plane and the
signaling and data traffic is exchanged
over the vFabric plane.
10GE 10GE 10GE 10GE 40GE 40GE 10GE 10GE 10GE 10GE 40GE 40GE 10GE 10GE 10GE 10GE 40GE 40GE
In the EVS networking, traffic between
MEZZ1 MEZZ2 MEZZ1 MEZZ2
VMs running on the same blade is
MEZZ1 VF MEZZ2
SR-IOV
OMU OMU
blades is exchanged through physical
SDU SPU IPU SPU
(standby) (standby)
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 75
Service Port Planning When CH121 V5 or CH121H
V3 Blades Are Used
Ports, on EOR switches, for switch stacks as well as north-
south and east-west traffic between VNFs and EOR switches
are planned as illustrated in the figure above.
The number of ports required for east-west traffic as well as
switch stacks is determined by the service traffic volume.
For more details on cable connections, see the network
design document.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 76
Virtual Switching Methods Used by Logical Networks
of Management Nodes (CH121 V5 or CH121H V3)
OVS; NICs are Multiple vNICs share
bound and work one 40GE physical
in active/standby NIC and work in load-
mode. sharing mode.
10G 10G 40G 40G 40G 40G 10G 10G 40G 40G 40G 40G 10G 10G 40G 40G 40G 40G
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 77
Virtual Switching Methods Used by Logical Networks
of EMS Service Nodes (CH121 V5 or CH121H V3)
40GE Stack 40GE
CX710(1E) 40GE
CX920(2X) CX920(3X) 40GE internal_base
CX710(4E)
40GE 40GE
40GE 40GE 40GE 40GE 40GE 10GE 10GE 40GE 40GE 40GE 40GE 10GE 10GE 40GE 40GE 40GE 40GE 40GE 40GE 40GE external_api
Stack
external_om
Stack Stack
NICs are bound
and work in load- storage_data1
sharing mode.
HA
eth0 eth1 eth2 eth3 eth4 eth5
VNFM_Network_VIM
bond bond
storage_data1
VNFM_Network_Internal
OVS OVS
external_om OSS_Service
internal_ OSS_Self_
base external_api Maintenance
ha VNFM_Network_
Internal
VNFM_Network_VIM
Blade (CH121HV3)
E9000 (Management Domain)
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 78
SR-IOV Networking Used by Logical Networks of Clo
udEPC Service Nodes (CH121 V5 or CH121H V3)
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 79
EVS Networking Used by Logical Networks of CloudE
PC Service Nodes (CH121 V5 or CH121H V3)
Load-sharing Load-sharing
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 80
Contents
3. Networking
3.1 E9000 Networking
3.2 2288 Networking
3.3 HP C7000 Networking
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 81
RH2288H V3 or 2288H V5 Physical Networking
The RH2288H V3 or 2288H V5 uses four NICs (one onboard NIC
and three PCIe NICs):
1. Onboard NIC (2 x 10GE): is used to transmit NFVI management
and storage traffic (integration of NFVI management and
storage is recommended in the version) and provides external
ports to connect to the NFVI management and storage TOR
(CE6855).
2. PCIe1 (2 x 10GE): is reserved for storage in NFVI management
and storage separation scenarios and provides external ports to
connect to the storage TOR (CE6855). For example, the NIC is
used at China Mobile and China Unicom sites.
3. PCIe2 (2 x 10GE): is used for service east-west traffic. The
vFabric and vBase traffic of apps is connected to the service
TOR (CE6855) through the external port.
4. PCIe3 (2 x 10GE): is used for service north-south traffic. The
external service port of apps and O&M traffic are connected to
the service TOR (CE6855) through the external port.
5. 2288 hardware management is connected to the TOR (CE5855)
through the management network port.
6. The NFVI management TOR, storage TOR, service TOR, and
device management TOR are connected to the EOR
(CE12804S or CE12808S).
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 82
Virtual Switching Methods Used by Logical Networks
of Management Nodes (RH2288H V3 or 2288H V5)
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 83
Virtual Switching Methods Used by Logical Networks
of EMS Service Nodes (RH2288H V3 or 2288H V5)
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 84
SR-IOV Networking Used by Logical Networks of Cloud
EPC Service Nodes (RH2288H V3 or 2288H V5)
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 85
EVS Networking Used by Logical Networks of CloudEP
C Service Nodes (RH2288H V3 or 2288H V5)
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 86
Contents
3. Networking
3.1 E9000 Networking
3.2 2288 Networking
3.3 HP C7000 Networking
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 87
EVS Topology for the Network Running on HP C
7000 and FusionSphere
S ta c k T O R (N F V I S ta c k
T O R (N F V I
F C S w itc h F C S w itc h T O R (V N F tra ffic ) T O R (V N F tr a ffic )
s to ra g e & m g m t. tr a ffic ) s to ra g e & m g m t. tr a ffic )
4 *8 G E F C 4 *8 G E F C
VNF single Base plane
O A m o d u le _ 1 O A m o d u le _ 2
10G E 10G E 40G E
VNF OM plane
B a y 1 s iw tc h 2 0 G E S ta c k 2 0 G E B a y 2 s w itc h B a y 3 & 4 S w itc h s ta c k B a y 5 & 6 S w itc h s ta c k
20G E 20G E FC 10G E 10G E 10G E 10G E 10G E 10G E 10G E 10G E
ETH ETH ETH FC ETH ETH ETH
e th 0 FC e th 1 FC
w est
tra ffic
VNF Ext plane
ETH FC ETH FC 10G E 10GE 10G E 10G E
F -C OMU IP U S PU
(in H o s t)
B la d e ( C H 1 2 1 V 3 )
E 9 0 0 0 ( M a n a g e m e n t D o m a in )
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 88
FC SAN Topology for the Network Running on H
P C7000 and FusionSphere
HP C7000 Blades
Blades
Blades
FL VC FL VC
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
N N N N N N N N
F F F F F F F F
FC Storage data ports
FC Switch-1 FC Switch-2
GE Management ports
FC FC FC FC GE FC FC FC FC GE
Controller A Controller B
FC SAN
L2 Fabric
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 89
HP C7000+FusionSphere Networking Diagram
Subrack 1 Subrack 2 Subrack 3
Management Management
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 90
Contents
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 91
Management Operations
⑧SSH CE6851/CE7850/CE12804S
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 92
Alarm Management
Alarms
U2000 VNFM FusionSphere OpenStack, E9000,
S5500 V3, and CE6851&CE12804S
Alarms Alarms alarms are reported to FusionSphere
FusionSphere OpenStack OM/eSight.
OpenStack OM
Cloude /eSight FusionSphere OpenStack OM/eSight
CloudUSN CloudUGW CloudCG
PDG
then reports the NFVI alarms to the
FSP VNFM.
Alarms
The VNFM then reports the NFVI
(FSP Controller) alarms to the U2000.
Alarms
VNF alarms are reported to the
U2000.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 93
Contents
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 94
Glossary (Solution and Product)
CloudEdge is the solution name used in both layered cloud and pre-
CloudEdge N/A integration scenarios.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 95
Glossary (VNFC, VNF Component)
Full Name Acronyms and Abbreviations Description
The VNFP provides functions including OM proxy, management of
Virtualized Network Function Platform VNFP
virtualized devices, VNFC management, and bus communication.
The VNRS_VNFC is a VNFC instance that provides link layer
Virtualized Network Routing Service VNFC VNRS_VNFC
protocols and routing protocols.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 96
Glossary (VDU, Virtualization Deployment Unit)
Full Name Acronyms and Abbreviations Description
Operation Management Unit OMU An OMU is a VM instance and is used to deploy VNFC O&M RUs.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 97
Questions
What does the architecture of the layered cloud solution (CloudEdge solution) loo
k like?
What are the networking differences when the CH121 V3, CH121H V3, or CH121
V5 is used?
What are the differences between the RH2288H V3+E9000 networking and RH22
88H V5+E9000 networking?
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 98
Conclusion
The layered cloud solution (CloudEdge solution) using the E9000 or RH2288 is re
commended.
Copyright © 2018 Huawei Technologies Co., Ltd. All rights reserved. Page 99
Thank you
www.huawei.com