Professional Documents
Culture Documents
ELE - Inter1.1 - Charging Detail - DX225LCA
ELE - Inter1.1 - Charging Detail - DX225LCA
Expandable Directory
Components of power supply system (DX225LCA)
Target
Contents
Warning signal
to EPOS
To EPOS
Energizing
field coil
Under starter switch ON/ Engine stop condition, Battery power goes
into alternator B terminal
Energizing field coil initially
Warning signal with not charging condition
Charging system
Charging system To starter controller
Engine running
To battery
Warning signal
to EPOS
To fuse box
To EPOS
Engine running
To battery
Warning signal
to EPOS
To fuse box
To EPOS
While engine running, discharging power from R(I) makes battery relay
be connecting condition, that is why discharging power could be charged
on battery
And finally alternator rotating is stop, battery relay will be disconnected
Charging system
Charging system
Engine running
Diode
Above 3.3V
O
from alternator
Zener
Below 3.3V X Diode
from alternator
Zener diode works till 3.3V of discharging voltage power from R(I)
Charging system
Charging system