SIN2011_4

Charging system of DX225LCA


HOW TO NAVIGATE
Resources
- Attachment link to view
any associated information
Outline View to this course

Expandable Directory
Components of power supply system (DX225LCA)

Target

- To understand charging system with related components


- To understand alternator detail

Contents

- Exact location and name, function of major components with pictures


- Components detail on the pictures
Quiz & Answer

Questions of charging system

1. What is main function of zener diode on R(I) line on alternator ?

2. Where the P(R) signal go to?

3. Why does battery power go to alternator B(B+) terminal under starter


switch ON with engine stop condition?
Charging system
Components of charging system To starter controller

Review component name and wiring

To EPOS (Charging warning)


Charging system
Charging system To starter controller

Engine stop/Start switch ON

Warning signal
to EPOS

To EPOS
Energizing
field coil

Under starter switch ON/ Engine stop condition, Battery power goes
into alternator B terminal
 Energizing field coil initially
 Warning signal with not charging condition
Charging system
Charging system To starter controller

Engine running

To battery
Warning signal
to EPOS
To fuse box

To EPOS

While engine running, discharging power from B(B+) goes to battery


and fuse box
Discharging power from P(R) goes to starter controller to protect re
starting by operator
Charging system
Charging system To starter controller

Engine running

To battery
Warning signal
to EPOS
To fuse box

To EPOS

While engine running, discharging power from R(I) makes battery relay
be connecting condition, that is why discharging power could be charged
on battery
And finally alternator rotating is stop, battery relay will be disconnected
Charging system
Charging system

Engine running

Diode
Above 3.3V
O
from alternator

Zener
Below 3.3V X Diode
from alternator

Zener diode works till 3.3V of discharging voltage power from R(I)
Charging system
Charging system

Try to check indicated point value at machine with multi meter


① ② ③ ① ② ③

Engine stop condition Engine running condition


① with ground : 0V ① with ground : 13.5V
② with ground : 0V ② with ground : 27.5V
③ with ground : 0V ③ with ground : 27.5V
Trace wiring
Trace wiring

Let’s trace charging system wiring on schematics


 Starting from battery
COURSE SUMMARY – DX225LCA Components

Thank you for your attention

• In this course, you have

☞ Power supply Components of Doosan DX225LCA Excavator

Continue to ‘Course survey’ & ‘Quiz’ to complete the course.

You might also like