• Additional building sewer cleanout shall be installed for each


aggregate change in direction exceeding ____ degrees.
False
• (T or F) Paint, varnish or other coatings shall be permitted o the
jointing material before testing the joints.
61 m
• The public seer may be considered as not being available when such
public sewer or any exterior drainage facility connected thereto is
located more than ___ from any proposed building or exterior
drainage facility on any lot or premises thereat.
1
• F.U for 32mm pipe size.
51
• Minimum trap diameter (mm) for service sink.
2
• Each fixture trap shall have a protecting vent so located that the
developed length of the trap arm from the trap weir to the inner edge
of the vent shall be in no case less than ____ time the diameter of the
trap arm.
3m
• Vertical vent pipes for outdoor installations shall extend to at least
____ distant from any part of the roof that is used for other purposes.
1m
• The yoke vent connection with the vent stack shall be placed not less
than ____ meter above the floor level.
True
• (T or F) No rain, surface or subsurface waters shall be connected to a
private or public sewage disposal system unless permission has first
been obtained from the Administrative Authority.
0.3 meter
• One of the requirement for use drainage piping of clay or materials
which are not approved for use within a building is that the bottom of
the water pipe at all points, shall be at least ____ above the top of the
sewer or drain line.
1500
• Minimum fixture unit loadings on building sewer piping (0.5% slope)
for 254 mm (8 inch) building sewer.
Schedule 40
• Minimum site of ABS pipe for downspout within the interior of the
building.
25 ga
• Rainwater downspout or conductor located on the exterior side of a
low height building shall be not less than ___ galvanized sheet metal.
Discharge
• No domestic dishwashing machine shall be directly connected to a
drainage system of food waste disposer without the use of an
approved dishwasher airgap fitting on the ___ side of the dishwashing
machine.
152 mm
• Vent size diameter if the boiler blow off is 64 mm.
25.4 mm
• Minimum condensate pipe diameter of with equipment capacity of 20
tons of refrigeration (70.33 kw)
1.6 mm
• The thickness of the sheet lead shall not be less than ___ thick for
safe pans.
1780 mm
• The minimum area and dimension shall be maintained from a point
above the shower drain outlet to a height of ____ with no protrusions
other than the fixture valve or valves, shower head and safety grab
bars or rails.
15.2 m

• Minimum horizontal distance required from building sewer to the


streams.
Vent pipe
• Each plumbing fixture trap shall be protected against siphonage and
back-pressure by properly placed _______.
Soil/stack
• The size of yoke vent shall be not less in diameter than either the
____ or the ____, whichever is smaller.
1/3
• No more than ____ of the total permitted length, per Table 7-5 of any
minimum sized vent shall be installed in a horizontal position.
0.3 meter
• No building sewer or other drainage piping or part thereof,
constructed of materials other than those approved for use
underground shall be installed not less than ____ below the finish
surface of the ground.
40
• Rainwater piping located within a medium height building basement
area shall be DWV copper tube Schedule ____ ABS.
3/5
• Rainwater piping commencing ___ meter from the exterior of a
building may be suitable approved materials pennitted in the
installation requirements of this Code.
1.07 m
• Horizontal distance of trap arms to vent except for water closets and
similar fixtures with trap arm diameter 38 mm.
Square
• Inspection is called.
19 mm
• Wiped lead joints shall have an exposed surface on each side of a
joint not less than ____ and at least as thick as the material being
joined.
3.2 mm
• Lead bends and lead traps shall not be less than ___ in wall thickness.
American Society of Testing and Materials
• ASTM
Trough
• Any water closet, which might pen nit siphon age of the contents of
the bowl back into the water tank, shall be prohibited as well as ____
urinals.
2%
• The finished floor of the receptor shall slope uniformly from the sides
towards the drain not less than ___.
3.05 m
• Horizontal distance of trap arms to vent except for water closets and
similar fixtures with trap arm diameter 102 mm and larger.
1
• The vent through the roof (VSTR) shall be increased ____ pipe size
above the reconnection point of stack vent and horizontal vent.
2.1 m
• Vertical vent pipes for outdoor installations shall extend not less than
____ above the roof used for other purposes
51 mm
• Minimum condensate pipe diameter of with equipment capacity of
250 tons of refrigeration (879.2 kw)
2
• DFU for bathtubs.
2
• DFU for single stall shower.
11.5
• Threads per 25.4 mm for 51 mm pipe.
72
• Maximum slope (degrees) from vertical or short horizontal drainage
pipe with no cleanout.
51 mm
• Cast iron fittings up to and including ___ in size, when used in
connection with potable water piping shall be galvanized.
1.52 m
• Installations elevated more than ____ above the floor or grade shall
be provided with permanent platform capable of supporting a tester
or maintenance person
3 days
• It shall be the duty of the Registered and Licensed Master Plumber to
notify the Administrative Authority not less than ____ before the
inspection.
Flood level rim
• When using the tailpiece of a fixture to receive the discharge of an
aspirator, the airgap shall be located above the ____ of the fixture.
25 mm
• Where potable water is discharged to the drainage system, it shall be
by means of an approved airgap not less than ___ from the supply
outlet and the top surface of the drainage inlet.
0.3 m
• The water pipe shall be paced on a solid shelf excavated at one side of
the common trench with a minimum clear horizontal distance
between the sides of at least ____ from the side of sewer or drain line
and the water line.
75
• Water piping systems may be designed by taking the total length of
the supply piping from the source of the cold water supply through
the water heater to the most remote hot water outlet ad assessing
flow values of __ % of the combined hot and cold water demand.
103 kPa
• Whenever the water pressure in the main or other source of supply
will not provide a water pressure of at least ___, a hydro-pneumatic
pressure tank or an elevated tank and booster pump will provide the
said pressure.
152 mm
• Vacuum breaker for water closet and urinal flushometer valves shall
be installed at the discharge side of the flushometer valve with the
critical level at least ___ or the distance according to its listing above
the overflow rim f a water closet bowl or the highest part of a urinal.
True
• (True or False) Tests may be conducted in the presence of the
representative of the Administrative Authority.