Ashish Kumar

32114206 Experiment-2

Asymmetrical AC Controller
Alpha 45 Degrees
230 volts Supply Voltage at 50 Hz and Resistance is 10 ohms

Firing Angle Vo RMS Io RMS THD PF

30 226.7 22.67 0.15 0.998

45 219.3 21.93 0.25 0.994

60 206.3 20.63 0.37 0.986

75 187.3 18.73 0.5 0.948

90 162.6 16.26 0.65 0.878

105 133.5 13.35 0.81 0.774

120 101.7 10.17 1.02 0.636

135 69.32 6.93 1.3 0.469

150 39.06 3.90 1.73 0.279


Symmetrical AC controller
230 Volts RMS at 50 Hz supply and R=10 ohm

Firing Angle Vo RMS THD PF

30 223.3 0.27 0.99

40 214.4 0.38 0.996

50 200.2 0.56 0.992

60 179.5 0.8 0.983

70 150.3 1.15 0.983

80 107.8 1.88 0.983

90 0.7273 316.2 0.88


Vo VS Firing Angle
Integral Cycle Control
Input Frequency =50hz Total Run cycle =10, Fo=5hz
Turn on cycle=4
No. of Turn on RMS o/p voltage THD
cycle
1 72.73 15.88
2 102.9 11.79
3 126 10.48
4 145.5 10.29
5 162.2 10.95
6 178.2 12.63
7 192.4 16.05
8 205.7 23.64
9 218.2 47.73

Output=75 % of input
N=4, M=3, T=7

RMS I/P RMS O/P THD


230 173.9 8.292
Output=75 % of input
N=4, M=3, T=7

O/P=50% of Input
N=1,M=3,T=4

RMS I/P RMS O/P Voltage THD


230 V 115 V 4.043
For 25% N=1,M=15,T=16

RMS I/P RMS O/P THD


230 57.5 32.07
PWM Based AC Controller

Fraction X=0.5
Input RMS = 230, 50Hz , 10 pulses per cycle

Fraction X Vo RMS THD in Vo THD in Io


1 0.62 210.1 210.1
0.8 102.9 2 2
0.6 145.5 1.225 1.225
0.4 178.2 0.82 0.82
0.2 205.7 0.5 0.5
0 230 0 0