Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 12

WELL CONTROL

BOP Accumulator unit ( Koomey unit )

1
WELL CONTROL
BOP Accumulator unit ( Koomey unit )

2
WELL CONTROL
Usable Fluid
Accumulator Bottle Size 10 Gallon
Boyle’s Low :
P1 V 1 = P 2 V 2 = P 3 V 3
V1 P1 3000 PSI
Therefore :
P3V3 P3V3
V1 = and V2 =
P1 P2 V2
V3 VU = V 2 – V1
With VU = V2 – V1 P2

The Formula Becomes


1200 PSI
VU =
P3 V 3
P2 - P 3 V3
P1
P3
1000 PSI

VU =
1000X10
1200
- 1000X10
3000
VU = 5 Gallon

3
WELL CONTROL
Shutting In a Well From Remote Panel.

Accumulator ANNULAR Manifold

OPEN CLOSE

Rig Air Annular

BLIND RAMS
OPEN CLOSE
Close Open
Manifold PIPE RAMS
OPEN CLOSE

KILL LINE CHOKE LINE

Vent

PIPE RAMS
OPEN CLOSE

4
WELL CONTROL
Bulb Has Blown.

Accumulator ANNULAR Manifold

OPEN CLOSE

Rig Air Annular

BLIND RAMS
OPEN CLOSE
Close Open
Manifold PIPE RAMS
OPEN CLOSE

KILL LINE CHOKE LINE

Vent

PIPE RAMS
OPEN CLOSE

5
WELL CONTROL
Micro Switch Is Faulty.

Accumulator ANNULAR Manifold

OPEN CLOSE

Rig Air Annular

BLIND RAMS
OPEN CLOSE
Close Open
Manifold PIPE RAMS
OPEN CLOSE

KILL LINE CHOKE LINE

Vent

PIPE RAMS
OPEN CLOSE

6
WELL CONTROL
Hydraulic Line Is Plugged.

Accumulator ANNULAR Manifold

OPEN CLOSE

Rig Air Annular

BLIND RAMS
OPEN CLOSE
Close Open
Manifold PIPE RAMS
OPEN CLOSE

KILL LINE CHOKE LINE

Vent

PIPE RAMS
OPEN CLOSE

7
WELL CONTROL
Leak In Hydraulic System.

Accumulator ANNULAR Manifold

OPEN CLOSE

Rig Air Annular

BLIND RAMS
OPEN CLOSE
Close Open
Manifold PIPE RAMS
OPEN CLOSE

KILL LINE CHOKE LINE

Vent

PIPE RAMS
OPEN CLOSE

8
WELL CONTROL
4-Way Valve Failed To Shift.

Accumulator ANNULAR Manifold

OPEN CLOSE

Rig Air Annular

BLIND RAMS
OPEN CLOSE
Close Open
Manifold PIPE RAMS
OPEN CLOSE

KILL LINE CHOKE LINE

Vent

PIPE RAMS
OPEN CLOSE

9
WELL CONTROL
4-Way Valve Failed To Shift.

Accumulator ANNULAR Manifold

OPEN CLOSE

Rig Air Annular

BLIND RAMS
OPEN CLOSE
Close Open
Manifold PIPE RAMS
OPEN CLOSE

KILL LINE CHOKE LINE

Vent

PIPE RAMS
OPEN CLOSE

10
WELL CONTROL
Master Control Valve Is Not Depressed With
The Control Valve Of The Function.

Accumulator ANNULAR Manifold

OPEN CLOSE

Rig Air Annular

BLIND RAMS
OPEN CLOSE
Close Open
Manifold PIPE RAMS
OPEN CLOSE

KILL LINE CHOKE LINE

Vent

PIPE RAMS
OPEN CLOSE

11
WELL CONTROL
No Air Pressure Is Going To The Remote Panel.

Accumulator ANNULAR Manifold

OPEN CLOSE

Rig Air Annular

BLIND RAMS
OPEN CLOSE
Close Open
Manifold PIPE RAMS
OPEN CLOSE

KILL LINE CHOKE LINE

Vent

PIPE RAMS
OPEN CLOSE

12

You might also like