REVA

CARLO B. BIENES

LIDA
TOPICS THAT WILL BE COVERED

DUTIES & BROILER DESIGN &


RESPONSIBILITIES CONCEPT LAYOUT
MAIN DUTIES AND RESPONSIBILITIES

PREPARE QUOTATIONS (CONTRACTS)

PROVIDE GENERAL LAYOUTS BASED ON


QUOTATIONS (CONTRACTS)
FUNCTION IN RELATION TO SALES:
PROVIDE QUOTATION AND GENERAL LAYOUTS FOR
THEIR CLIENT ENGAGEMENT/ PRESENTATION

FUNCTION IN RELATION TO FINANCE/ACCOUNTING:


CHECKS PRICES IN QUOTATIONS MADE

FUNCTION IN RELATION TO PROJECT ENGINEERS:


PROVIDE INFORMATION OF THE DATAILS OF THE
DESIGN, QUOTATION AND BUDGET FOR
INSTALLATION
FUNCTION IN RELATION TO LOGISTICS:
COORDINATION STOCKS & PRICES OF EQUIPMENT
THAT WILL BE USED IN THE PROJECT
CLIMATE
CONTROL PARAMETERS
SYSTEM

FEEDING
SYSTEM REGULAR
BROILER
HOUSE

DRINKING STORAGE
SYSTEM SYSTEM

BROODING TRANSPORT
SYSTEM SYSTEM
Tunnel ventilation is a type of exhaust system. The fans act like pumps
to move air through cooling pads. It removes heat and excess moisture,
to minimize dust and odors, to limit the buildup of harmful gases such
as ammonia and carbon dioxide and to provide oxygen for respiration.

CLIMATE
COOLING
CONTROL PADS

SYSTEM
FANS
FANS

ZA 36”, 1.5 HP MUNTERS 52” 1.5 HP YSD 50” 1.5 HP ZA 48” 3P


AIR CAPACITY: AIR CAPACITY: AIR CAPACITY: AIR CAPACITY:
24, 800 cmh 24, 800 cmh 32,300 cmh 45, 000 cmh
YSD 50” 1.5 HP
AIR CAPACITY:
45,000 cmh
*Minimum distance b/w fans: 0.15m
COOLING PADS
STANDARD SIZE: 6’ X 2’ X 6” & 5’ X 2’ X 6”
60 sqf = 20 000 cfm – capacity of cooling pads
@25 PASCAL
SOME HAS CURTAINS SOME HAS TUNNEL DOORS

HUMIDITY: must be lower than 85%


if it goes higher than 85%, cool pads will
shut off
CLIMATE
CONTROL PARAMETERS
SYSTEM

FEEDING
SYSTEM REGULAR
BROILER
HOUSE

DRINKING
SYSTEM STORAGE
SYSTEM

BROODING TRANSPORT
SYSTEM SYSTEM
FEEDING SYSTEM
A feeding system allows a large number of animals to be feed in a short
time so that each gets its portion and to have an equal opportunity to eat
an equal amount of feed simultaneously.
DRINKING SYSTEM
A water equipment that allowing a good access to water in sufficient
quantity and quality supply of water in chickens.
BROODING SYSTEM
Provide heat from day old chicks to 7 days old or provide heat from
brooding stage. Provide more radiant energy that chicks needed. Chicks
required 33-34 degree Celsius.

HEATS OBJECT AND CHICKS DIRECTLY W/O HEATING THE AIR # of Brooders 5hp=
INFRARED • KROMS 5000 HP
• KROMS 6000 HP
no. of birds/1750

# of Brooders 6hp=
HEATS SURROUNDING BY HEATING THE AIR no. of birds/2250
SPACE • BOX HEATER
HEATING • CYLINDRICAL HEATER
TRANSPORT SYSTEM
Automatic transport of feeds from day bin to buffer.

FLEX-AUGER HAVING NOVICOR QUALITY HAS


HIGHER WEAR RESISTANCE THAN PVC
COUNTERPART. IT ALSO HAS HIGH TEMPERATURE
RESISTANCE.

Tube dia. 55 mm
Tube dia. 75 mm

Tube dia. 90 mm

Tube dia. 125 mm


REGULAR BROILER HOUSE
BUILDING SIZE: 52ft x 450ft x 7ft (15.85m x 138m x 2.13m)

5 LINES DRINKING LINES & 4 LINES FEEDING LINES

3600 BIRDS CAPACITY

I-TYPE GUTTER SYSTEM


PARAMETERS NEEDED TO START DESIGN AND LAYOUT OF BROILER HOUSE

FARM DETAILS SIZE OF BUILDING

AIR SPEED 1 PHASE/ 3 PHASE POWER SUPPLE

NO. OF BIRDS COOLING PAD LAYOUT


AFTER WE GET ALL THOSE DETAILS WE CAN START
WITH CCS CALCULATOR IN EXCEL
DESIGN &
LAYOUT
MANDALUYON CITY
FILL IN FARM NAME, LOCATION &
TYPE OF PROJECT

FILL IN BUILDING SIZE

FILL IN NUMBER OF FANS THAT


WOULD SATISFY AIR SPEED
REQUIREMENT, TYPE OF FANS CAN
ALSO BE CHANGED.

QUANTITY WOULD AUTOMATICALLY


DISPALYED, YOU CAN CHANGE IT TO
KROMS 5000 HP, 6000 HP AND
KROMS GP70

QUANTITY WOULD AUTOMATICALLY


DISPALYED, YOU CAN CHANGE SIZE
TO 6FT OR 5FT.
ONCE WE ARE FINISHED WITH THE E-QUOTE, WE WILL GET THIS DATA IN THE
GENERATED QUOTATION DOCUMENT. WE WILL FILL THIS DATA LATER ON
STANDARD QUOTATION EXCEL.
QUOTATION FOR BROILER

IN DETAILS TAB:

CELLS WITH YELLOW


HIGHLIGHT NEEDS TO
BE FILLED IN WITH
DATA
IN ROXELL QUOTE TAB, FILL IN DATA
GATHERED FROM GENERATED
QUOTE OF E-QUOTE
DOUBLE CHECK DATA AND
PRICES
AFTER FINISHING THE QUOTATION,
SEND THE QUOTATION TO FINANCE
FOR CHECKING. ONCE CHECKED, SEND
TO SIR KENNY FOR APPROVAL. IF
UNAVAILABLE, TO SIR 1RM OR DOC A.
BROILER LAYOUT

CROSS-
FAN SECTIONAL
PROVISIONS
LAYOUT

FLOOR EQUIPMENT COOL


PLAN LAYOUT PADS
WE CREATE LAYOUT BASED ON THE QUOTATION MADE.
Clear span – no post
in between
FLOOR
PLAN
4m intervals b/w
frames

Service Rooms-
2.5m x (3 or 4 m)

Doors :
Gate: 2.8 x 2m
Walk-in doors:0.9m x 1.8m
Doors for cooling corridor:
0.6m x 1.8 m

Cooling Corridors:
2 sets of 1m x
(depends on length
of cool pads)
FAN
PROVISIONS Roof Slope: 20%

Dwarf Wall: 50 cm
height

Ground to eaves:
2.13 m

60 cm canopy shall
extend beyond wall
EQUIPMENT
LAYOUT
CROSS-
SECTIONAL
LAYOUT
COOL
PADS