Professional Documents
Culture Documents
ITF O-Ring Detection
ITF O-Ring Detection
22.01.28
History
1. Background
- We had a customer complaint due to O-ring missing.
2. Cause
- The O-ring is placed in the ITF at station 50 manually.
- The O-ring is not visible to make a revision in the following stations.
3. Improvement
- Leak test machine, the port tester was modified.
Increase 2.13mm of length.
Inner diameter were increase to 9.61mm
- With this, the O-ring is making the seal.
Appendix – Results after improvement
■ ITF O-ring detection on Leak test
- Piece with O-ring the port tester make a seal and the pressure get into the set values.
- Piece without O-ring, the port tester don’t make seal with anything and the pressure doesn’t reach set values.