PC160 Monitor Service Mode MPTS ™
PC160 Monitor Service Mode MPTS ™
PC160-7-1 1
SERVICE MODE
To access the service mode
Key in the following :-
PC160-7-1 2
SERVICE MODE
1. Monitoring
2. Abnormality Record
3. Maintenance record
4. Maintenance mode change.
5. Phone number entry
6. Default
7. Adjustment
In the flashing yellow box key in the number selection or use the
up/down arrow to move your selection and then press return.
PC160-7-1 3
SERVICE MODE
1. Monitoring measurement items
Within the monitoring function we can monitor
up to four measurement items on the machine
However for a fast screen update use only on
a single item. Only 2 measurement items can be
displayed in conjunction with an On/off display
PC160-7-1 4
SERVICE MODE
1. Monitoring measurement items
PC160-7-1 5
SERVICE MODE
1. Monitoring
On/off display items
PC160-7-1 6
SERVICE MODE
2. Abnormality Record (electrical)
The machine monitor stores two types of failure information
1. Electrical failures.
2. Mechanical failure.
To access the information select, “ 02 Abnormality record” from
within the Service mode and you will see the screen displaying
the choice of failure codes. A max of 20 codes can be stored then
the oldest code is erased.
1 2
PC160-7-1 7
SERVICE MODE
PC160-7-1 8
SERVICE MODE
2. Abnormality Record (Mechanical)
When the mechanical failures are selected we are displayed with
11 failure codes with the number of times each failure has
occurred and the hours when the first occurrence took place.
The mechanical failure codes cannot be erased.
Use the up/down buttons to scroll through the list.
6 164 h
PC160-7-1 9
SERVICE MODE
3. Maintenance Record
PC160-7-1 12
SERVICE MODE
6. Default Setup.
When the default setup screen is selected it allows to change
the settings that the machine will start up in every time it is
switched on.
The “Key-on mode” allows the selection of the mode each
for operator preference at start up.
Default value
sets to the
current set value
PC160-7-1 13
SERVICE MODE
6. Default Setup.
The other default setup screens are for language (Japanese/English)
Unit (SI unit, Metric, Imperial)and selection of
“with or without service circuit” .
If the Service Circuit is not selected then the Icon is
removed from the standard screen at the mode symbol.
equipped
PC160-7-1 14
SERVICE MODE
7. Adjustment.
From within the service mode the adjustment section allows
the service technician to carry various adjustments to the
machines performance.
PC160-7-1 15
SERVICE MODE
7. Adjustment. Governor motor adjustment
The ability to ensure the governor motor is kept at maximum
RPM setting is required to ensure the linkage between
the Governor motor and the fuel injection pump is correct.
To activate this function carry out the following :-
1. Ensure fuel dial is at maximum
2. Set the monitor panel the the adjustment selection
3. Adjust the length of the linkage to ensure lever touches the stop.
See the shop manual for detailed instructions
PC160-7-1 16
SERVICE MODE
7. Adjustment. Pump absorption torque
Due to machine tolerances the pump absorption torque can
be adjusted to suit the machine.
Using the Up/Down button selection can be made to the torque
absorbed by the pump.
PC160-7-1 17
SERVICE MODE
7. Adjustment. Low idle speed adjustment
The low idle setting on the governor can also be adjusted
suit the operator to the values shown below.
PC160-7-1 18
SERVICE MODE
7. Adjustment. Service current adjustment
During compound operation between the boom raise spool and
the service spool the distribution of the flow from the
hydraulic pump would choose to go to the service spool ,
therefore the ability to alter the flow distribution is given in
the monitor panel . By selecting the different values below we alter
the balance of flow between the spools.
370
371
372
373
PC160-7-1 19
SERVICE MODE
7. Adjustment. Service current adjustment
- Flow: 0.5 times
- Adjustment Code: 370 (Default)
Monitor ATT Flow EPC Current
Scale (l/min) (mA)
8 (Full) 219 593
7 179 542
6 128 496
5 87 460
4 71 446
3 59 435
2 46 423
1 30 409
PC160-7-1 20
SERVICE MODE
7. Adjustment. SMR adjustment
By inputting 90 in the flashing yellow box in the adjustment screen
the SMR adjustment screen can be selected.
To activate the function Press up arrow together with 1-2-3
in sequence.
This function is required if the monitor panel is replaced and
the Current hours are transferred from the old Monitor panel.
You cannot decrease the hours and the monitor does not go back to
zero hours if you go past 99999hours.
The SMR can be checked on the machine with the key switch in the
off position. To activate hold the Up Arrow button and the Return button
pressed at the same time for 3-5 seconds to activate .
TEST screen mode can be operated by pressing Button 2 with the return key
PC160-7-1 22
Return to Menu Click box