Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 51

HUAWEI OSN 8800

Hardware Reference
Contents
1. Cabinet and Subrack

2. Cards
1. Optical Transponder Unit
2. Optical Multiplexer, Demultiplexer, Add and Drop Unit
3. Optical Amplifier Unit
4. Other Boards

3. Links with 8800 equipments

2 Proprietary and Confidential


Cabinet and Subrack
Cabinet

• Dimension:
• 2.2×0.6×0.6m (H×W×D)
• Maximum power consumption:
10kW
• Working power supply:
• –48 V to –60 V DC (Normal Working voltage)
• –40 V to –72 V DC (Working voltage range)

4 Proprietary and Confidential


Subrack I

5 Proprietary and Confidential


Subrack II

6 Proprietary and Confidential


Board Area (Subrack I)

7 Proprietary and Confidential


Board Area (Subrack II)

8 Proprietary and Confidential


Board Area (Subrack II)

9 Proprietary and Confidential


Optical Transponder Units

10
ND2 Board
• Application:
ND2: 2 x 10G line service processing board. The ND2 board supports
cross-connections of ODU0, ODU1 and ODU2 signals from the
crossconnect board and provides OTN interfaces and ESC.

• Valid slots
One slot houses one ND2 board. The valid slots for the ND2 board
are IU1-IU8, IU12-IU27, and IU29-IU36 in OptiX OSN 8800 I.The
valid slots for the ND2 are IU1-IU8, IU11-IU42, IU45-IU68 in OptiX
OSN 8800 II.
• Maximum Power Consumption
67W to 77W

• Interfaces

11 Proprietary and Confidential


ND2
Technical Specifications

12 Proprietary and Confidential


NQ2 Board
• Application:
As a type of line unit, the NQ2 board realizes conversion between 32
channels of ODU0 signals or 16 channels of ODU1 or 4 channels of
ODU2 signals and 4 channels of WDM OTU2 signals that comply
with ITU-T Recommendations, or between four channels of ODU2e
signals and four channels of OTU2e signals. In addition, the NQ2
board supports hybrid transmission of these services.

• Valid slots
One slot houses one NQ2 board. The valid slots for the NQ2 board
are IU1-IU8, IU12-IU27, and IU29-IU36 in OptiX OSN 8800 I. The
valid slots for the NQ2 are IU1-IU8, IU11-IU42, IU45-IU68 in OptiX
OSN 8800 II.

13 Proprietary and Confidential


NQ2
• Interfaces

• Maximum Power Consumption

14 Proprietary and Confidential


NQ2
• Technical Specifications

15 Proprietary and Confidential


TQX Board
• Application:
4 x 10 Gbit/s tributary service processing board. TQX board realizes the
conversion between four 10GE LAN/10GE WAN/STM-64/OC-192/OTU2
optical signals and four ODU2/ODU2e electrical signals through cross-
connection, supports hybrid transmission of the 10GE LAN/10GE WAN/STM-
64/OC-192/OTU2 services.

• Valid slots
The TQX ocuppies 1 slot. The valid slots for the TQX board are IU1-IU8, IU12-
IU27,and IU29-IU36 in OptiX OSN 8800 I.The valid slots for the TQX are IU1-
IU8, IU11-IU42, IU45-IU68 in OptiX OSN 8800 II.

• Maximum Power Consumption


91.5 W at 25ºC 100W at 55ºC

• Interfaces

16 Proprietary and Confidential


TQX
Technical Specifications

17 Proprietary and Confidential


TOG Board
• Application:
8 x GE service processing board. The TOG board realizes conversion between
8 channels of GE optical signals or GE electrical signals and 8 channels of
ODU0 electrical signals through crossconnection.

• Valid slots
The TOG ocuppies 1 slot. The valid slots for the TOG board are IU1-IU8, IU12-
IU27, and IU29-IU36 in OptiX OSN 8800 I. The valid slots for the TOG board
are IU1-IU8, IU11-IU42, IU45-IU68 in OptiX OSN 8800 II.

• Maximum Power Consumption


41.8 W at 25ºC 46W at 55ºC

• Interfaces

18 Proprietary and Confidential


TOG
Technical Specifications

19 Proprietary and Confidential


TOG
Technical Specifications

20 Proprietary and Confidential


TOM Board
• Application:
8 x multi-rate ports service processing board. The TOM can be used as client-
side interfaces or WDM-side interfaces. The maximum access capacity of the
TOM at the client side is 10 Gbit/s.

• Valid slots
The TOM ocuppies 1 slot. The valid slots for the TOM board are IU1-IU8, IU12-
IU27, and IU29-IU36 in OptiX OSN 8800 I. The valid slots for the TOM are IU1-
IU8, IU11-IU42, IU45-IU68 in OptiX OSN 8800 II.

• Maximum Power Consumption


81 W at 25ºC 89.1W at 55ºC

• Interfaces

21 Proprietary and Confidential


TOM
Technical Specifications

22 Proprietary and Confidential


Optical Multiplexer, Demultiplexer, Add and Drop Unit
RDU, WSM9 and WSD9 can be used in 8800 shelf, but CLARO is usedc them in 6800
shelf.

23
RDU9
• Application:
As a type of reconfigurable optical add and drop multiplexing unit, the RDU9
board is used with the WSM9 board to realize the wavelength grooming at the
nodes in the DWDM network.

• Valid slots
One slot houses one RDU9 board. The valid slots for the RDU9 board are IU1-IU8, IU12-
IU27, and IU29-IU36 in OptiX OSN 8800 I.The valid slots for the RDU9 are IU1-IU8, IU11-
IU42, IU45-IU68 in OptiX OSN 8800 II.

• Maximum Power Consumption


6 W at 25ºC 6.6W at 55ºC

24 Proprietary and Confidential


RDU9
• Interfaces

25 Proprietary and Confidential


RDU9
Technical Specifications

26 Proprietary and Confidential


WSD9
• Application:
As a type of reconfigurable optical add and drop multiplexing unit. The WSD9
board is used with the WSM9 or RMU9 board to realize wavelength grooming
at the nodes in the DWDM network.

• Valid slots
Two slots house one TN12WSD9 board. Three slots house one TN13WSD9
board. The validslots for the TN12WSD9 are IU1-IU7, IU12-IU18, IU20-IU26,
IU29-IU35 in the subrack in OptiX OSN 8800 I. The valid slots for the
TN13WSD9 are IU1-IU6, IU12-IU17, IU20-IU25, and IU29-IU34 in the subrack
in OptiX OSN 8800 I.The valid slots for the TN12WSD9 are IU1 IU7, IU11-
IU17, IU19-IU25, IU27-IU33, IU35-IU41, IU45-IU51, IU53-IU59, IU61-IU67 in
OptiX OSN 8800 II. The valid slots for the TN13WSD9 are IU1-IU6, IU11-IU16,
IU19-IU24, IU27-IU32, IU35-IU40, IU45-IU50, IU53-IU58, IU61-IU66 in OptiX
OSN 8800 II.

• Maximum Power Consumption

27 Proprietary and Confidential


WSD9
• Interfaces

28 Proprietary and Confidential


WSD9
Technical Specifications

29 Proprietary and Confidential


WSM9
• Application:
As a type of reconfigurable optical add and drop multiplexing unit, the WSM9
board is used with the WSD9 board to realize wavelength grooming at the
nodes in the DWDM network.

• Valid slots
Two slots house one TN12WSM9 board. Three slots house one TN13WSM9
board. The valid slots for the TN12WSM9 are IU1-IU7, IU12-IU18, IU20-IU26,
IU29-IU35 in the subrack in OptiX OSN 8800 I. The valid slots for the
TN13WSM9 are IU1-IU6, IU12-IU17, IU20-IU25, and IU29-IU34 in the subrack
in OptiX OSN 8800 I.The valid slots for the TN12WSM9 are IU1-IU7, IU11-
IU17, IU19-IU25, IU27-IU33, IU35-IU41, IU45-IU51, IU53-IU59, IU61-IU67 in
OptiX OSN 8800 II. The valid slots for the TN13WSM9 are IU1-IU6, IU11-IU16,
IU19- IU24, IU27-IU32, IU35-IU40, IU45-IU50, IU53-IU58, IU61-IU66 in OptiX
OSN 8800 II.

• Maximum Power Consumption

30 Proprietary and Confidential


WSM9
• Interfaces

31 Proprietary and Confidential


WSM9
Technical Specifications

32 Proprietary and Confidential


Optical Amplifier Unit

33
OAU1
• Application:
As a type of optical amplifier unit, the OAU1 board amplifies optical signals at
the transmit end or receive end.

• Valid slots
Two slots house one OAU1 board. The valid slots for the OAU1 board are IU2-IU8, IU12-
IU19, IU21-IU27, and IU30-IU36 in the subrack in OptiX OSN 8800 I. The valid slots for the
OAU1 are IU2-IU8, IU12-IU18, IU20-IU26, IU28-IU34, IU36-IU42, IU46-IU52, IU54-IU60,
IU62- IU68 in OptiX OSN 8800 II.

34 Proprietary and Confidential


OAU1
• Front Panel

35 Proprietary and Confidential


OAU1
• Interface

• Power Consumption

36 Proprietary and Confidential


OAU1
Technical Specifications

37 Proprietary and Confidential


OAU1
Technical Specifications

38 Proprietary and Confidential


OBU1
• Application:
As a type of optical amplifier unit, the OBU1 board amplifies optical signals. The OBU1
board is of three types: OBU101, OBU103 and OBU104

• Valid slots
One slot houses one OBU1 board. The valid slots for the OBU1 are IU1-IU8,
IU11-IU27, and IU29-IU36 in OptiX OSN 8800 I. The valid slots for the OBU1
are IU1-IU8, IU11-IU42, IU45-IU68 in OptiX OSN 8800 II.

39 Proprietary and Confidential


OBU1
• Front Panel

40 Proprietary and Confidential


OBU1
• Interface

• Power Consumption

41 Proprietary and Confidential


OBU1
Technical Specifications

42 Proprietary and Confidential


Others Board
XCH
• Application:
OptiX OSN 8800 I centralized cross connect board. The XCH cross-connects services.

• Valid slots
The XCH ocuppies one slots. The valid slots for the XCH board are IU9 and
IU10.

• Power Consumption
243 W at 25ºC 261W at 55ºC

44 Proprietary and Confidential


SCC
• Application:
As a type of system control and communication unit, the SCC board works with the
network management system to manage each board and realizes inter-equipment
communication.

• Valid slots
One slot houses one TN51SCC/TN52SCC board. The valid slots for the SCC
board are IU11 and IU28 in OptiX OSN 8800 I.One slot houses one TNK2SCC
board. The valid slots for the SCC board are IU74 and IU85 in OptiX OSN
8800 II.

• Power Consumption

45 Proprietary and Confidential


SCC
• Front Panel:

46 Proprietary and Confidential


Links with Huawei 8800 equipments
LINKS
• Red OTN (Todo el pais)
• Red ROADM en AMBA

48 Proprietary and Confidential


Manuals Reference
REFERENCE
• OSN880_Hardware Description.
• OSN880_Product Description

50 Proprietary and Confidential


Thank You.