Professional Documents
Culture Documents
HUAWEI OSN 8800 - Hardware Reference
HUAWEI OSN 8800 - Hardware Reference
Hardware Reference
Contents
1. Cabinet and Subrack
2. Cards
1. Optical Transponder Unit
2. Optical Multiplexer, Demultiplexer, Add and Drop Unit
3. Optical Amplifier Unit
4. Other Boards
• Dimension:
• 2.2×0.6×0.6m (H×W×D)
• Maximum power consumption:
10kW
• Working power supply:
• –48 V to –60 V DC (Normal Working voltage)
• –40 V to –72 V DC (Working voltage range)
10
ND2 Board
• Application:
ND2: 2 x 10G line service processing board. The ND2 board supports
cross-connections of ODU0, ODU1 and ODU2 signals from the
crossconnect board and provides OTN interfaces and ESC.
• Valid slots
One slot houses one ND2 board. The valid slots for the ND2 board
are IU1-IU8, IU12-IU27, and IU29-IU36 in OptiX OSN 8800 I.The
valid slots for the ND2 are IU1-IU8, IU11-IU42, IU45-IU68 in OptiX
OSN 8800 II.
• Maximum Power Consumption
67W to 77W
• Interfaces
• Valid slots
One slot houses one NQ2 board. The valid slots for the NQ2 board
are IU1-IU8, IU12-IU27, and IU29-IU36 in OptiX OSN 8800 I. The
valid slots for the NQ2 are IU1-IU8, IU11-IU42, IU45-IU68 in OptiX
OSN 8800 II.
• Valid slots
The TQX ocuppies 1 slot. The valid slots for the TQX board are IU1-IU8, IU12-
IU27,and IU29-IU36 in OptiX OSN 8800 I.The valid slots for the TQX are IU1-
IU8, IU11-IU42, IU45-IU68 in OptiX OSN 8800 II.
• Interfaces
• Valid slots
The TOG ocuppies 1 slot. The valid slots for the TOG board are IU1-IU8, IU12-
IU27, and IU29-IU36 in OptiX OSN 8800 I. The valid slots for the TOG board
are IU1-IU8, IU11-IU42, IU45-IU68 in OptiX OSN 8800 II.
• Interfaces
• Valid slots
The TOM ocuppies 1 slot. The valid slots for the TOM board are IU1-IU8, IU12-
IU27, and IU29-IU36 in OptiX OSN 8800 I. The valid slots for the TOM are IU1-
IU8, IU11-IU42, IU45-IU68 in OptiX OSN 8800 II.
• Interfaces
23
RDU9
• Application:
As a type of reconfigurable optical add and drop multiplexing unit, the RDU9
board is used with the WSM9 board to realize the wavelength grooming at the
nodes in the DWDM network.
• Valid slots
One slot houses one RDU9 board. The valid slots for the RDU9 board are IU1-IU8, IU12-
IU27, and IU29-IU36 in OptiX OSN 8800 I.The valid slots for the RDU9 are IU1-IU8, IU11-
IU42, IU45-IU68 in OptiX OSN 8800 II.
• Valid slots
Two slots house one TN12WSD9 board. Three slots house one TN13WSD9
board. The validslots for the TN12WSD9 are IU1-IU7, IU12-IU18, IU20-IU26,
IU29-IU35 in the subrack in OptiX OSN 8800 I. The valid slots for the
TN13WSD9 are IU1-IU6, IU12-IU17, IU20-IU25, and IU29-IU34 in the subrack
in OptiX OSN 8800 I.The valid slots for the TN12WSD9 are IU1 IU7, IU11-
IU17, IU19-IU25, IU27-IU33, IU35-IU41, IU45-IU51, IU53-IU59, IU61-IU67 in
OptiX OSN 8800 II. The valid slots for the TN13WSD9 are IU1-IU6, IU11-IU16,
IU19-IU24, IU27-IU32, IU35-IU40, IU45-IU50, IU53-IU58, IU61-IU66 in OptiX
OSN 8800 II.
• Valid slots
Two slots house one TN12WSM9 board. Three slots house one TN13WSM9
board. The valid slots for the TN12WSM9 are IU1-IU7, IU12-IU18, IU20-IU26,
IU29-IU35 in the subrack in OptiX OSN 8800 I. The valid slots for the
TN13WSM9 are IU1-IU6, IU12-IU17, IU20-IU25, and IU29-IU34 in the subrack
in OptiX OSN 8800 I.The valid slots for the TN12WSM9 are IU1-IU7, IU11-
IU17, IU19-IU25, IU27-IU33, IU35-IU41, IU45-IU51, IU53-IU59, IU61-IU67 in
OptiX OSN 8800 II. The valid slots for the TN13WSM9 are IU1-IU6, IU11-IU16,
IU19- IU24, IU27-IU32, IU35-IU40, IU45-IU50, IU53-IU58, IU61-IU66 in OptiX
OSN 8800 II.
33
OAU1
• Application:
As a type of optical amplifier unit, the OAU1 board amplifies optical signals at
the transmit end or receive end.
• Valid slots
Two slots house one OAU1 board. The valid slots for the OAU1 board are IU2-IU8, IU12-
IU19, IU21-IU27, and IU30-IU36 in the subrack in OptiX OSN 8800 I. The valid slots for the
OAU1 are IU2-IU8, IU12-IU18, IU20-IU26, IU28-IU34, IU36-IU42, IU46-IU52, IU54-IU60,
IU62- IU68 in OptiX OSN 8800 II.
• Power Consumption
• Valid slots
One slot houses one OBU1 board. The valid slots for the OBU1 are IU1-IU8,
IU11-IU27, and IU29-IU36 in OptiX OSN 8800 I. The valid slots for the OBU1
are IU1-IU8, IU11-IU42, IU45-IU68 in OptiX OSN 8800 II.
• Power Consumption
• Valid slots
The XCH ocuppies one slots. The valid slots for the XCH board are IU9 and
IU10.
• Power Consumption
243 W at 25ºC 261W at 55ºC
• Valid slots
One slot houses one TN51SCC/TN52SCC board. The valid slots for the SCC
board are IU11 and IU28 in OptiX OSN 8800 I.One slot houses one TNK2SCC
board. The valid slots for the SCC board are IU74 and IU85 in OptiX OSN
8800 II.
• Power Consumption