Andhra Pradesh Building Rules – 2012
3
PARAMETERS OF BUILDING
RULES
It regulates
• Plot size
• Road Width
• Setbacks
• Plot coverage
• Floor Area
• Height
• Parking Area
• Enforcement
• Restriction of buildings in certain areas,
Since the Building Rules are issued in many GOs for regulating
in the State
Congested areas
Existing areas
Maintaining greenery
Flexibility in transferring of setbacks
Solar Power for Heating and External Lighting
Structure stability and earthquake resistance in major
complexes
Facilities for Physically Challenged persons in the public
buildings
Contd..
Andhra Pradesh Building Rules – 2012
11
TABLE – II (AS PER GO.86)
Minimum abutting road width
Type/ Use of Building plot permissible
required (in meters)
B) SITES IN NEW AREAS/ APPROVED LAYOUT AREAS
The type of buildings & intensity of development shall be w.r.t. the abutting road width, viz.,
B2 In addition to B 1 above, High Rise Building/ Complex of height above 18 m and up 12.2
to 24 m; Group Housing Scheme; Primary School, Middle school / Tutorial institution
/ General Industry / Godown / Petrol/diesel Filling station; High School, Junior
College / Commercial Complex, Computer units/ Office Building, ITES Complex,
Nursing Home / Community Hall / Function/Marriage Hall / Assembly Hall/Cinema
Theater; Service establishment/ Workshop;
Others not specified in the Table and all non high-rise buildings up to 18 m height
All Residential (other than Group Housing) & Commercial Buildings. For other
categories the Minimum road width shall be as given in B1 Category 10 9*
High Rise Buildings / Complexes, Non High Rise Group Housing (Cellars as applicable + 24 12
B2 6 floors), Group Housing with more than 100 units, Group Development Scheme; Middle
school / Tutorial institution / General Industry / Godown / Petrol / Diesel / Gas Filling
Station; High School, Junior College / Commercial Complex, Computer units/ Office
Building, ITES Complex, Nursing Home/ Hospital of not more than 20 beds / Community
Hall / Function/Marriage Hall / Assembly Hall /Cinema Theater; Service establishment /
Workshop;
Others not specified in the Table and all Non High-Rise buildings up to 18m height
Electrical Lines
For High Tension electrical lines a minimum safety distance (both horizontal
and vertical) of 3m shall be maintained between the building and high tension
electrical lines and 1.5m for low tension electrical lines
The land all along the tower line shall be developed as green belt to an extent of
the width of tower base and on either side of green belt there shall be a minimum
of 10m wide roads or as defined in the Master Plan, which ever is higher.
The building heights and other parameters shall be regulated as per the stipulations
of the Airport Authority of India as notified in Gazette of India Extraordinary
(S.O.1589) dated 30-06-2008
Irrespective of their distance from the aerodrome, even beyond 22km limit from the
aerodrome reference point, no radio masts or similar installation exceeding 152m in
height shall be erected except with the prior clearance from Civil Aviation
Authorities.
In respect of any land located within 1000m from the boundary of Military Airport
no building is allowed except with prior clearance from the concerned airport
authority with regard to building height permissible and safe distance to be
maintained between the building and boundary of the aerodrome.
Slaughter house, Butcheries, Meat shops and Solid Waste disposal sites and
other areas for activities like depositing of garbage which may encourage
collection of high flying birds, like eagles and hawks, shall not be permitted
within 10 km from the Airport Reference Point.
Such requirement may stipulate the prohibition of any cavity, niche, or other
opening on the exterior of such building / installation / structure so as to
prevent the nesting and habitation of pigeon or other birds.
Sl.No Type A B
1 Buildings and >20000sq.m and #(Built up are for covered construction; in
Construction <1,50,000sq.m of built case of facilities open to the sky, it will be
Projects up area# the activity area
2 Townships and Covering an area > ++All projects under Item8(b) shall be
Area 50ha and or built up appraised as Category B1
Development are >1,50,000sq.m ++
Projects
Defense Establishments
In case of Sites within 500m distance from the boundary of Defense Areas /
Military Establishments prior clearance of Defense Authority shall be
obtained.
Oil/Gas Pipelines
In case of Sites in the vicinity of Oil/Gas pipelines, clearance distance and
other stipulations of the Respective Authority shall be complied with.
The Oil / Gas Authorities shall also specify the clearances required stretch
wise to Local Body.
Heritage Structures
In case of Sites located within the distance up to 100m from protected monuments as
notified under Archeological Monuments and Ancient Sites and Remains Act 1955
and as amended no construction is allowed.
For the Sites located within distance of above 100m and up to 200m from the
protected monuments, the construction is allowed only after obtaining prior
permission from the National Monument Authority.
For the Sites located within the vicinity of any Heritage Structure notified as per the
respective law, the prior clearance from the concerned authority shall be obtained.
In case of Sites located within a radius of 100m from the notified religious structure as given in
the list in Annexure – VII / notified from time to time, the construction is allowed upto 10m
height only.
For the Sites located within a radius of above 100m and up to 300m from the notified religious
structure as given in the list in Annexure – VII / notified from time to time, only non high rise
• The building with height beyond 10m in these areas shall be permitted only if the plot
abuts to a minimum of 12m wide road
• The setbacks shall be as per Table-III and parking & other requirement shall be as per
these rules.
Andhra Pradesh Building Rules – 2012 Contd.. 21
TABLE – III (AS PER G.O.86) Permissible Setbacks & Height
Building line or minimum front setback
(in mts) to be left Minimum
Height setbacks on
Sl. Plot Size Parking Above Above Above
permissible (in remaining
No. (in Sq.mts.) provision Up to 12m & 18m & 24m & Above
mts.) sides
12m upto upto upto 30m
(in mts.)
18m 18m 30m
1 2 3 4 5 6 7 8 9 10
1 Less than 100 - 7 1.5 4 5 6 7.5 -
1 2 3 4 5 6 7 8 9 10
7 Above 750 & Stilt parking Upto 7 3 4 5 6 7.5 3.0
upto 1000 + One cellar Upto 12 3 4 5 6 7.5 3.5
floor allowed Below 15 3 4 5 6 7.5 4.0
7 3 4 5 6 7.5 1.5
5 300 - 400 Stilt floor
12 3 4 5 6 7.5 2.0
7 3 4 5 6 7.5 2.0
6 400 - 500 Stilt floor
12 3 4 5 6 7.5 2.5
7 3 4 5 6 7.5 2.5
Stilt floor
7 * 500 - 750 12 3 4 5 6 7.5 3.0
15 3 4 5 6 7.5 3.5
7 3 4 5 6 7.5 4.0
Stilt +
1500 -
10 2 Cellar 15 3 4 5 6 7.5 5.0
2500
floors
18** 3 4 5 6 7.5 6.0
Stilt + 7 3 4 5 6 7.5 5.0
Above 2 or more
11 15 3 4 5 6 7.5 6.0
2500 Cellar
floors 18** 3 4 5 6 7.5 7.0
25
SALIENT FEATURES
In Table-II, Category-A & B front setback is insisted after widening the road to 9m (in case of
plots abutting less than 9m road)
Stilt Floor meant for parking is excluded from the permissible height in the above Table-III
For commercial plots having an extent of 500-750sq.m cellar floor for parking may be considered
If the site abuts more than one road, then the front setback should be insisted towards the bigger
road width and for the remaining side or sides, the setback as at column 11 In Table-III shall be
insisted
Height of stilt floor shall not be less than 2.5m and shall not exceed 3.0m.
In case of parking floors where mechanical system and lift are provided, height of such parking
floor shall not be less than 4.5m.
The transfer of setback from any one side to any other side without exceeding overall
permissible plinth area, subject to maintaining a minimum 2.5m setback on other side
(in case of plots above 750sq.m)
Narrow Plots is redefined as plot having extent not more than 400sq.m where the
length is four times of the width of the plot and the setbacks on sides may be
compensated in front and rear setbacks subject to maintain minimum setback of 1m
for buildings height upto 10m and 2m in case of height above 10 to 15m without
exceeding overall permissible plinth area and this is not applicable for made up plots
The space between block to block shall not be considered for organized open space (tot
lot)
High Rise Buildings / Complexes shall be permissible only in areas other than those
given in Annexure – I (congested areas) & II (prohibited for High Rise Buildings).
Minimum size of plot shall be 2000sq.m.
High Rise Building shall be accompanied by detailed plans, floor plans of all floors and
detailed specifications duly certified by a qualified structural engineer.
Prior Clearance from Airport Authority
Prior NOC from the Fire & Emergency Services Department
10% of total site area shall reserved for organized open space at ground level open to
sky and shall be a minimum width of 3m and minimum area of 50sq.m at one location.
The balcony projection of up to 2m may be allowed projecting onto the open spaces for
upper floors from 6m height onwards.
It shall be developed together with buildings and amenities and facilities – open plots
A through public access of 12m width shall be developed with in the applicants site for
the convenience of accessibility for other sites. This would not apply if there is an existing
peripheral road.
Minimum 3% of proposed built up area shall be developed for common amenities and
Provision for Mechanical and car lift system are proposed enabling two tier parking. The
In Stilt floor a watchman room and 2 toilets (W.C), with maximum built up area of
25sq.m may be allowed. Such space shall not be disposed and shall be part of common
2m in the sites of extent of more than 1000sq.m and less than 2000sq.m
4 Residential Apartment
Complexes, Hospitals, Institutional
buildings, Industrial buildings,
Schools, Colleges, other 30 20 20 20 20 20
educational buildings & Godowns
& Others
dispose or utilize elsewhere, in lieu of surrendering land free of cost which is required to
be set apart or affected for public purpose as per the Master Plan or in road widening or
TDR can be awarded only when such lands are transferred to the local body / Urban
The award would be in the form of a TDR certificate issued by the Competent
For the Master Plan Road / Road Development Plan undertaken and developed:
For conservation and development of lakes / water bodies / nalas foreshores &
Recreational buffer development with greenery, etc: equivalent to 100% of built up area
For Heritage buildings and heritage precincts maintained with adaptive reuse:
No fees and charges would be levied for parking spaces provided in any floor.
The Sanctioning Authority with the specific approval of the Government may, when implementing such
Projects, levy Special fees and other fees / charges for lands / sites / premises abutting or in the vicinity of
the Ring Road or other highways / major roads or the Mass Rail Transit System / Light Rail Transit /
MMTS route indicated in the Master Plan, at the rates and procedure prescribed by the Government.
• This is not applicable for Government Departments and Public Agencies like Urban
Development Authority, APIIC, Local Bodies and HMWSSB.
• The amount levied and collected shall be credited and maintained in a separate
escrow account and 50% of it shall be utilised for development of infrastructure in
the same area and balance amount is to be utilised towards improvement of city level
capital infrastructure.
Contd.. 43
SALIENT FEATURES
INCENTIVES
• If the site area is above 300sq.m and upto 1000sq.m. prior Technical Approval from
the concerned Regional Deputy Director shall be obtained where the proposed
activity is permissible in normal course as per Zoning Regulations.
• Where the Town Planning Section Head is in the cadre of Deputy Director or above,
the Sanctioning Authority is empowered to sanction the building permission in plot
area upto 1000sq.m, in the sites where the proposed activity is permissible in normal
course as per Zoning Regulations.
• Other than “i” & “ii” above the proposals of building approvals shall be submitted to
The Director of Town and Country Planning for prior Technical Approval.
• In the Gram Panchayat areas covered under sanctioned GTP Scheme the Sanctioning
Authority is empowered to sanction the individual residential building permission up
to 10m height in plot area upto 300sq.m, in the sites where the proposed activity is
permissible in normal course as per Zoning Regulations. In respect of other cases
prior Technical Approval shall be obtained from the Competent Authority i.e.
Director of Town & Country Planning.
• In Case of Group Development, Group Housing Schemes like Cluster Housing / Row
Housing / Semidetached Housing Schemes and Gated Community, Technical
approval from the Competent Authority is required to be obtained.
The Committee shall give the recommendations to the Metropolitan Commissioner / Vice
Chairman.
The Panchayat Secretary shall submit the proposal through the concerned RDDTP to
place before the committee and the committee shall give the recommendations to the
Director of Town & Country Planning
• For all high rise buildings, the work shall be subject to inspection by the Fire and
Emergency Service Department and the Occupancy Certificate shall be issued only after
clearance from the Fire and Emergency Service Department
• The functional/line agencies dealing with electric power, water supply, drainage and
sewerage shall not give regular connections to the building unless such Occupancy
Certificate is produced, or alternatively may charge 3 times the rate till such time
Occupancy Certificate is produced.
• The above condition shall also be applicable to all unauthorized constructions and
buildings constructed without sanctioned building plan. In addition to the above, the
Local Body shall collect every year two times the property tax as penalty from the
owner/occupier.
• The Registration Authority shall register only the permitted built up area as per the
sanctioned building plan and only upon producing and filing a copy of such
sanctioned building plan.
• The financial agencies/institutions shall extend loan facilities only to the permitted
built up area as per the sanctioned building plan.
• The Enforcement Authority shall summarily remove any violation or deviation in building
construction in maintaining the road widths and building line.
• In respect of apartment complexes, shopping complexes and all high rise buildings, periodical
inspections shall be carried out
• Any person or anybody including the Govt. are carries out development in contravention of
the rules shall be punished with imprisonment for a term which may extend to 3 years or
• A fine which may extend to 10% of the land value or building as fixed by the registration
dept.
• The engaging of the services of a licenced developer / builder shall be mandatory for
Apartment Buildings, Group Housing, all types of Group Development Schemes, all
High-Rise Buildings and all Commercial Complexes.
• Any licenced developer / builder / other technical personnel who undertake construction in
violation of the sanctioned plans shall be black-listed and this, this would entail cancellation
of their licence besides being prosecuted under the relevant laws / code of conduct.
2 5 (b) (ii) of 5. Restrictions of building activity in 3 (a) (ii) (1) 45m from the edge of the M.C. Rajahmundry has informed
G.O.302,678 & vicinity of certain areas River outside the that no. of structures are existing
569 b) (ii)100 meters from the River Municipal Corporation / very near to Godavari River. As
edge outside Municipal Municipality / Nagara they are existing since long time
Corporation /Municipal limits and 50 Panchayat limits and 30m and to avoid unauthorized
with in the Municipal construction he requested to
meters within Municipal Corporation/
Municipal limits. No permanent Corporation / reduce the buffer at least to 10m.
constructions / structures will be Municipality / Nagara In view of the above modification is
permitted within the above-mentioned Panchayat limits. considered
buffer zone.
COMPARATIVE STATEMENT SHOWING THE PRESENT RULE POSITION (G.O.Ms.No.86,
678, 302 & 569) AND PROVISIONS MADE IN PROPOSED RULES (AP BUILDING RULES-
RULE NO /
2012)
MODIFIED
SL.NO PROVISION MODIFICATION REMARKS
G.O.Ms.No RULE NO
3 5 (g) (i) In Case of Bajanra Hills and Jubilee Hills 3 (j) Apartment Complexes and Institutional Buildings
there is height ceiling of 15m for both are also permissible
residential and commercial buildings
the height beyond 10m in these areas
shall be permitted only if the plots
abuts to minimum 40ft wide road.
The above provision shall not be
applicable to Apartment complexes
4 7 Table-III 1. less than 100sq.m site area Front 5 Table-III 1. less than 50sq.m site area Front setback is Smaller Plots abutting to
G.O.86, setback is varying from 1.5m to 7.5m varying from 1.5m to 3m and on other sides no roads of higher width are
678,302 & and setback on other side is varying setback unable to leave the required
569 from 0m to 1.5m front setbacks due to high
2. 50-100sq.m site area Front setback is varying
front setback. In order to
2. 100-200sq.m site area Front setback from 1.5m to 3m and on other side setback is
remove the difficulty faced
is varying from 3m to 7.5m and setback varying from 0m to 0.5m
by small plots holder, and to
on other side is 1m
3. 100-200sq.m site area Front setback is varying encourage compliance of the
3. 200- 300sq.m site area Front from 1.5m to 3m and on other side is 1m on other building approvals the front
setback is varying from 3m to 7.5m and side setback is varying 1m setback is reduced for plots
setback on other side is 1m to 1.5m
4. 200-300sq.m site area Front setback is varying up to 300m site area to cater
from 2m to 6m and on other sides varying from the needs of the small plot
1m to 1.5m holders.
5 7.1 (g) (xii) of In case 5(f) (viii) viii. In case of plots 300 - 750sq.m, it is permitted to It is proposed to
G.O.86, 678 of plots above 300 sq. & (ix) transfer up to 1m of setback from any one side to any avoid the misuse
& meters and upto 750 sq. other side without exceeding overall permissible of the existing
meters, it is permitted to plinth area. The transfer of setback from front provision
7.1 (i) (f) (11)
of transfer up to one meter of setback is not allowed.
setback from one side to the ix. In case of plots above 750sq.m, it is permitted to
G.O.302 & other side, and in case of
transfer up to 2m of setback from any one side to any
7.1 (p) of 569 plots above 750 sq. meters,
other side without exceeding overall permissible
it is permitted to transfer up
plinth area, subject to maintaining of a minimum
to 2 meters of setback,
2.5m setback on other side and a minimum building
which needs to be uniform
line. The transfer of setback from front setback is not
at any given point, subject
allowed
to maintaining of minimum
building line in the front.
6 5(d) c.*In case of commercial buildings proposed in plots To provide
having an extent of 500-750sq.m cellar floor for parking facility
parking may be considered subject to condition that for commercial
required parking shall be fulfilled as per Table-V and buildings in
feasibility on ground smaller site
COMPARATIVE STATEMENT SHOWING THE PRESENT RULE POSITION (G.O.Ms.No.86,
678, 302 & 569) AND PROVISIONS MADE IN PROPOSED RULES (AP BUILDING RULES-
2012)
RULE NO / MODIFIED
SL.NO PROVISION MODIFICATION REMARKS
G.O.Ms.No. RULE NO
7 7.1(b) of Stilt parking floor permissible is 5(f) (ix) iii. Height of stilt floor shall Maximum height of the stilt floor
exclusive of height of building up not be less than 2.5m. In is removed and only minimum
G.O.86, 678,
to 15mts. height of stilt floor case of parking floors height is indicated as 2.5m to
302 & 569
shall not exceed 3.0mt. In case where mechanical system have a better clarity
of parking floors where and lift are provided, height
mechanical system and lift are of such parking floor shall
provided, height of such parking not be less than 4.5m.
floor upto 4.0mt. could be
considered.
8 9.6 Table-IV For high rise buildings of height 7(a)(ix) Required setback for the It is desirable to have more
of above 50m alround setback is buildings of height up to setbacks for increasing heights of
G.O.86,678, 16m and abutting road width 55m is specified and after buildings beyond certain height
G.O. 302 30m 55m 0.5m additional And height restrictions is deleted
For the high rise buildings of setback for every 5m of in respect of Municipal
height shall be insisted
height more than 40m approval Corporations (G.O.302) and
G.O. 569 of the Govt. is required Municipalities (G.O.569) in order
to have uniform policy
For the high rise buildings of
height more than 30m approval
of the Govt. is required
COMPARATIVE STATEMENT SHOWING THE PRESENT RULE POSITION (G.O.Ms.No.86,
678, 302 & 569) AND PROVISIONS MADE IN PROPOSED RULES (AP BUILDING RULES-
2012)
RULE NO / MODIFIED
SL.NO PROVISION MODIFICATION REMARKS
G.O.Ms.No. RULE NO
9 7.1(g)(xiv) For narrow plots, Where 5(f)(x) For narrow plots having extent not This rule is being
G.O.86, 678, the length 4 times the more than 400sq.m and where the exploited by the
302 & 569 width of the plot the length is 4 times of the width of the applicants by making the
setbacks on sides may plot, the setbacks on sides may be plots as narrow plots by
be compensated in front compensated in front and rear setbacks amalgamating the plots
and rear setbacks so as so as to ensure that to fulfill the norms of the
to ensure that the the overall aggregate setbacks are narrow plots. Due to this
overall aggregate maintained in the site, subject to the buildings with height
setbacks are maintained maintaining a minimum of side setback of 18m with only 1m
in the site, subject to of 1m in case of buildings of height up setback is being
maintaining a minimum to 10m and minimum of 2m in case of constructed due to which
of 1m on each side. buildings of height the lighting and
above 10m and up to 15m without ventilation to the
exceeding overall permissible plinth neighboring buildings is
area. (This Rule shall not be applicable deprived. Hence this is
for made-up plots). suitably modified.
COMPARATIVE STATEMENT SHOWING THE PRESENT RULE POSITION (G.O.Ms.No.86,
678, 302 & 569) AND PROVISIONS MADE IN PROPOSED RULES (AP BUILDING RULES-
2012)
RULE NO / MODIFIED
SL.NO PROVISION MODIFICATION REMARKS
G.O.Ms.No. RULE NO
15 21 of OCCUPANCY 26 (b) OCCUPANCY CERTIFICATE Use of the building also made mandatory for
G.O.86,678 CERTIFICATE issue of occupancy certificate as it is
Parameters
& 302 Parameters observed that after obtaining approval for
*No. of Floors residential buildings are being converted for
22 of G.O. (a) Number of
floors External setbacks commercial uses, schools, colleges etc..
569
(b) External which the not permissible in certain locations
Usage of the building
setbacks and which require more parking area, NOC
(c) Parking space Parking space provision from Fire Services Dept. and many other
provision conditions.
Abutting road width
(d) Abutting road
* The total height of the Further with reference to height also the
width
building may vary to a deviations up to 1m subject to Fire Services
norms are prescribed which will facilitate to
maximum of 1m with no
change in the permitted obtain Occupancy Certificate depending on
number of floors subject to the ground condition.
compliance of fire service
norms