• Vent fittings shall be ___ except (A: vitrified clay, B: cast iron, C:
galvanized malleable iron or galvanized steel, D: lead, E: copper, F:
brass, G: ABS, H: PVC)
1/3
• The length of horizontal portion of a vent may exceed ____ of the
total length of vertical and horizontal portions as limited b Table 7.5 of
Plumbing code provided the vent is increased to one pipe size larger
for its entire length.
Backwater valve
• When subject to reverse flow of sewage or liquid waste, such floor
drains shall be equipped with an approved ____.
0.9 kg/mm
• In metallic shower sub pans, all folds, laps and reinforcing webbing
shall extent to at least 101 mm in all directions from the corner and
all webbing shall be of approved type and mesh, producing a tensile
strength of not less than ____ in either direction.
4%
• The finished floor of the receptor shall slope uniformly from the sides
towards the drain not more than ___.
Automatically controlled flush
• ______ maybe substituted for automatic flush tanks.
Red
• Color marking for type M copper tube
L
• Copper tube for water supply piping shall have a weight of not less
than type ___.
Asbestos cement sewer pipe joint
• Shall be a sleeve coupling of the same composition as the pipe or of
other approved materials, and sealed with neoprene rubber rings or
joined by an approved type compression coupling.
Burned lead joints
• Joined.
Pressure-Lock type Connection
• A mechanical connection which depends on an internal retention
device to prevent pipe or tubing separation.
K
• Heaviest type of copper pipe that is suitable for underground
installation.
0.2
• The sand interceptor shall have a minimum dimension of ___ m^2 for
the net free opening of the inlet section.
152 mm
• No galvanized malleable iron or galvanized steel fittings shall be
buried underground but shall be kept at least ____ above finish
ground level.
150 mm
• Vent pipes shall be extended separately or combined, of full required
size not less than ____ above the roof or fire wall.
Clear
• Minimum horizontal distance required from building sewer to the
property line adjoining private property.
300
• Minimum fixture unit loadings on building sewer piping (2% slope) for
254 mm (10 inch) building sewer.
Storm drainage
• ____ are required for roof areas, courts and courtyards to collect
storm water and discharge the storm water to an approved point of
disposal not in conflict with other ordinances or regulations.
Airgap
• Cooling and air-conditioning equipment may be separated by an
airbreak, but all food equipment shall be separated from the drainage
system by a full ____.
Funnel
• In disposal of cooling water, the upper end of trap connected to the
inlet side of fixture trap shall terminate in a ____ shaped receptacle.
12
• Condensers constructed of metal shall be not less than No. ___ U>S.
Standard gauge thickness.
Airgap
• Water lifts, expansion tanks, cooling jackets, sprinkler system, drip or
overflow pans or similar devices which discharge clear waste water
into the building drainage system shall discharge through an indirect
waste by means of an ____.
4
• F.U for 51mm pipe size
Vitrified clay
• Pipes or fittings which shall be kept at least 0.3 meter below ground.
6
• F.U for 76mm pipe size.
Combination waste and vent system
• CW & VS (provide complete words for the acronym)
152 mm
• All condensers and sumps shall be properly trapped at the outlet with
a deep seal trap extending to within ____ of the bottom of the tank.
Bituminous coating
• All metal condensers shall be protected from external corrosion by an
approved ______.
25 mm
• The airgap for drainage shall be not less than ____ between the
plumbing fixture, appliance or appurtenance outlet and the rim of the
floor sink or receptor.
Series 1000
• Minimum required standard (series) for downspout/conductor
30 days
• Where disposal facilities are abandoned consequent to connecting
any premises with the public sewer, the permittee making the
connection shall fill all abandoned facilities as required by the
Administrative Authority within from the time of connecting the
sewer service line to the public sewer.
15 meter
• Additional building sewer cleanout shall be installed no to exceed
____ on center in straight runs.
25
• The total capacity of fixtures discharging into any such grease trap
shall not exceed ____ times the certified liters per minute flowrate of
the grease trap.
0-Jan
• Thickness of copper pans or liners shall be at least _____ mm.
762 mm
• All shower compartments, regardless of shape, shall be capable of
encompassing a ____ diameter circle.
Self closing type
• Each such urinal flushometer valve shall be approved, ____ type
discharging a predetermined quantity of water.
6
• DFU for sand interceptor
0.6 m
• No urinal shall be set closer than 0.3 meter from its center to any
sidewall or partition nor closer than ____ center to center.
6.8
• No metallic shower sub-pans or linings may be built-up on the jobsite
of layers of standard grade ____ kg asphalt impregnated roofing tilt.
International Association of Plumbing and
mechanical officials
• IAPMO
Cast iron
• Gate valves with sizes 102 mm or larger in diameter shall have what
material of bodies?
14.63 kg
• The weight of the sheet lead shall not be less than ___ per sq. m for
flashings or vent terminals.
Green
Color marking for type K copper tube.
Union
• Approved ____ may be used in drainage work when accessibly
located in the trap seal or between a fixture and its trap; I the vent
system except underground or in wet vents, at accessible points in the
water supply piping system and in gas piping.
Mechanical joints
• Type for joint for that can be used in centrifugally cast iron water pipe.
1700
• Minimum fixture unit loadings on building sewer piping (0.5% slope)
for 305 mm (12 inch) building sewer.
Cleanouts
• Angles and changes of direction in indirect waste pipes shall be
provided with ___ to permit flushing and cleaning.
Open receptor
• Appliances, devices, equipment or other apparatus not regularly
classified as plumbing fixtures equipped with pumps, drips or
drainage outlets may be drained by indirect waste pipes discharging
into an approved-type____.
0.6
• In CW & VS, tailpiece or connections shall be as short as possible and
in no case shall exceed ____ meter long.
8
• F.U for 102 mm pipe size.