Engineering standards Arrangement of Exits

Planning Parameters of Institutional Buildings *Exits shall be located at travel distance not
*Minimum road width – min 9M exceed 22.50m in each floor
*Maximum Height – 18.30 M
*Maximum FSI – 2
* setback – 6m from all sides PARKING
*Maximum Coverage -50%
*Spacing between blocks in case of more than Colleges 1 car space for every 100sq.m of class room area
one block of High Rise building – 7M
and 1 two-wheeler space for every 50sq.m
CORRIDOR WIDTH
* research Institutions- 2M

Ramped Approach
*Minimum width of ramp shall be 1800mm
with maximum gradient 1:12 * minimum stall width shall be 2.7m aisle width
* with a landing of 2M for parallel parking
* minimum stall length shall be 7.2m
Lifts for car
*Clear internal width 1100 mm Clear internal
depth 2000 mm Entrance door width 900 mm

Stairways Requirements Width Entry and Exit Gates 4.5M minimum


*minimum width should be 2M
* minimum width of tread 0.3M
*maximum riser 0.15M OSR- 10% of the site
*landing minimum 0.9M

Name – Gayathri Ganesh


Reg.no – 724618251009 Reference
PUBLIC LIBRARY Sem.no – 5 TNDCR,NEUFERT,
ARCHITECTURAL DESIGN IV Sheet name – data NBC
collection
Sanitation Requirements
*Drinking Water Fountain One per 100 persons
MALES
* WC - For over 200 persons,1 per 250 persons Gangways
*URINALS - 1 for 50 persons *Longitudinal gangway not less than 1 m
*Wash Basins -For over 400 persons, add at the rate of 1 * Cross gangway not less than 1.35 m
per 250 persons * End gangway ( between the end wall and nearest row of
racks/reading table ) not less than 1.325 m.
FEMAL
*WC - over 200 persons, add at the 1 per 150 persons The dimensions of stack room
* Wash Basins - For over 200 persons, add at the rate of CLEAR LENGTH
1 per 150 persons * 1.80 n + 3.10 where n is the number of rows of book racks
* book rack 2 m long may be assumed to house 700 to 750
volumes and 1 m2 of stack room area may be assumed to house
For Staff 150 VOLUMES
Males
* WC - One for 1-15 persons. Two for 16- 35 persons
*URINALS - One for 7-20 persons Two for 21- 45 persons
*WASH BASIN -One for 1-15 persons Two for 16- 35
For Staff
Female

*WC - One for 1-12 persons. Two for


Longitudinal gangway not less than 1 m 13-25 persons.
Cross gangway not less than 1.35 m *WASH BASIN - One for 1-12
End gangway ( between the end wall and nearest row of persons Two for 13-25 persons
racks/reading table ) not less than 1.325 m.

Name – Gayathri Ganesh


Reg.no –724618251009
Reference
PUBLIC LIBRARY Sem - 5
ARCHITECTURAL DESIGN IV Sheet name – data
TNDCR,NEUFERT, NBC
collection
spaces area (m sq)

Librarian and deputy librarian 30


Group discussion room 2 per person
Conference room 2 per person
Seminar room 2 per person
Cubicles 2 per person
floor area for minimum
individual Distance between
workstation tables

Reading workstation examples


*The height of the rack is 2.20
*book shelves should protect from day light
*recommended temp for reading and open area is 22 deg
Celsius
in summer and 20 deg Celsius in winter
* recommended humidity level is 45% to 50%
Vbvbb

Free space in reading area

NAME – Gayathri Ganesh


PUBLIC LIBRARY REG.NO – 724618251009 Reference
ARCHITECTURAL DESIGN IV SEM – 5
TNDCR,NEUFERT, NBC
SHEET NAME – data collection
Bookshelves for
schoolchildren

5 shelve height

4 shelve unit for small kids

NAME – Gayathri Ganesh Reference


PUBLIC LIBRARY REG.NO – 724618251009
ARCHITECTURL DESIGN IV SEM – 5 TNDCR,NEUFERT,
SHEET NAME – data collection NBC
SITE ANALYSIS
Institutional and
college
LOCATION SURROUNDINGS Medical college
Avinashi road, civil aerodrome, Coimbatore agricultural land Agricultural land
geographical coordinates at center of plot
Site
11.0319 latitude, 77.0259 longitude
altitude 1609M
from sea

Proximity to transport hubs


• 25km from Coimbatore railway station APPROACH
• 8km from gandhipuram bus stand • Avinashi road 0.27km on south
• Codessia trade fair 1.5km at NE
• 10km from ukkadam bus stand • Existing access to the site 4m width

NAME – Gayathri Ganesh


PUBLIC LIBRARY REG.NO – 724618251009
ARCHITECTURL DESIGN IV SEM – 5
SHEET NAME – SITE ANALYSIS
Ddv • Sun path is from east to west through
north

At 7am At 9am
mng mng

Hydrology
• Storm water drain towards SE
side of site natural slope
• No natural water sources as
At 3pm pound, well are found in site.
At 12pm noon
eve • Proposed site should be aided
*wind direction is from SW TO NE during
with municipal water supply.
Jan to Sept and NE TO SW during oct to
Dec.
*precipitation is low in Jan 8mm, most of
Flat area with 4010 elevation
Precipitation is on oct average 151mm.
Riser area with 412 elevation
*Average temperature of 34deg Celsius,
April is the hottest month of the year, Highest area with 414 elevation
Slope
Jan to Dec
Dec is coldest month with 20 deg Celsius.

NAME – Gayathri Ganesh


PUBLIC LIBRARY REG.NO – 724618251009
ARCHITECTURL DESIGN IV SEM – 5
SHEET NAME – SITE ANALYSIS
DESIGN
• Good natural ventilation can reduce or eliminate air conditioning in warm weather.

If windows are well shaded and oriented to prevailing breezes.

d
oa
ir
• To provide stack ventilation, even when wind speeds are low, maximize vertical height

a sh
in
Av
between air inlet and outlet.
• Use plant materials (bushes, trees, ivy-covered walls) especially on the west to minimize

heat gain (if summer rains support native plant grow)

VENTILATION INSIDE THE IN CORPORATING


BUILDING PLANTS,SHRUBS,TREES

CROSS VENTILATION

NAME – Gayathri Ganesh


PUBLIC LIBRARY REG.NO – 724618251009
ARCHITECTURL DESIGN IV SEM – 5
SHEET NAME – SITE ANALYSIS
SegregationPUBLIC
of spaces LIBRARY

*walkways
Requirements *seating or gathering • Special
spaces • Stack area
collections
Given *OAT • Periodicals
• Reading area
*canteen or restaurant • Group work
*Stalk Area • Group work
*meditation area • Seminar room
*Reading area *plazas • E-book section
• Conference
*reading point • Back volume
* Group work area area
• Study rooms
*Digital Library • Recreation
• Conference
• E-book
*Audio Library • recreation
*Seminar room
• Reference
*Conference Room
• Reading area
*Reprography section • Conference • Audio library
*Librarian room • Groupwork • reading nook BIOPHILIC DESIGN
• Reprography • Visual library *Connection of building and occupants
* Locker space (theater) more closely to nature
• Study room
*Outdoor plazas • Recreation • Group work INCORPORATION
*Required parking • recreation *Natural light and ventilation, landscapes,
energy reduce and sustainable for future
by considering diseases and usability

NAME – Gayathri Ganesh


PUBLIC LIBRARY REG.NO – 724618251009
ARCHITECTURL DESIGN IV SEM – 5
SHEET NAME – concept and ideas
CONCEPT
WATER SPLASH

BASIC GEOMETRY
SHAPE CIRCLE
WILL BE IN plan
Elevation will be in
fluidical shape
Facade will be curved
Aesthetic
Use of sustainable material

No water body present


inside the site
So why not creating one?

Allowing maximum
The level of the
natural ventilation
building will be
and light and
depend on the
considering
fluidical motion
biophilic

NAME – Gayathri Ganesh


PUBLIC LIBRARY REG.NO – 724618251009
ARCHITECTURL DESIGN IV SEM – 5
SHEET NAME – concept and ideas