Misting Presentation by Sambyal
Agenda
Understanding of Requirement
Brief About Misting Applications
Approach(Design Considerations)
Solution Components
Indicative Project Timelines
Bill of Material
Demo Videos
Q&A
Understanding of Requirement
Out door cooling for retail area/shopping complex
Brief
About Misting & Application Areas
Misting System -is a series of misting nozzles placed
in a tube and pressurized to provide a fine spray
consisting of water droplets between 5 microns and 50
microns. This size of droplets requires a pressure of at
least 500 PSI, anything lower will produce larger
droplets and won’t provide an effective cooling effect.
Industry-standard pressure is 1000 PSI
Misting System Applications - most common
applications for high-pressure misting systems include
cooling, humidification, dust control, odor control, and
special effects
Approach(Design Considerations)
Building Specification (Length, Width, Height)-Covered or
Open Area
Water Supply Specifications
Regional Climate Condition
Avg. Max. Outside Temp.
Avg. Max. Outside Humidity
Approx. Elevation
Required Inside Temp.
Required Inside Humidity
Duration of running misting system in a day
Electrical Supply – Phase/Voltage/Frequency
Solution Components
-
Pump Pumps come in several varieties, including pulley
drive, direct drive, and a custom series. we provide the best
value and can provide you with a pump to meet your needs.
DIRECT DRIVEN
PULLEY DRIVEN PUMP
PUMPS
Solution Components
Tubing & Fittings-The quality of your tubing is directly
connected to the performance of your misting system. We
recommend our stainless steel or copper tubing for rigid
line systems and nylon with slip-lok fittings for our flexible
line systems.