Chapter 3 Cards
1529.55nm
196.00THz
C-EVEN C-band 1560.61nm
192.10THz
1529.16nm 1560.20nm
C-ODD
196.05THz 192.15THz
1570.42nm 1603.17nm
190.90THz
L-EVEN L-band 187.00THz
1570.82nm 1603.57nm
190.85THz L-ODD 186.95THz
STM-16 32 channels
STM-64 Convergence Layer
34M~2.7G 34M~2.7G
arbitrary bit rate LWX
155M/622M/2.5G 155M/622M
LWM
configurable /2.5G
Channel
Types Characteristics of six types of systems
spacing
OptiX BWS 50GHz Scalable 1600G system, support long haul and large capacity
1600G-I transmission.
OptiX BWS 100GHz 80 channel system (40 channels in C-band and 40 channels in L-
1600G-II band), each channel can carry up to 10Gbps, Maximum capacity is
800G.
OptiX BWS 100GHz 40 channels in C-band, each channel can carry up to 10Gbps,
1600G-III Maximum capacity is 400G.
OptiX BWS 100GHz For G.653 fiber, mainly be used in L-band.
1600G-IV
OptiX BWS 100GHz 40 channels in C-band, each channel can carry up to 2.5Gbps,
1600G-V Maximum capacity is 100G.
OptiX BWS 1 100GHz 40 channels in C-band, each channel can carry up to 10Gbps,
600G-VI Maximum capacity is 400G.
(LHP) 200GHz 10 channels in C-band, each channel can carry up to 10Gbps,
Maximum capacity is 100G.
Chapter 3 Cards
2.1 Cabinet
2.2 Subrack
Cabinet Dimension
A. 2200 (H) X 600 (W) X 300 (D)
B. 2600 (H) X 600 (W) X 300 (D)
ON ON ON ON ON ON
PO W ER IN SW 1 SW 2 SW 3 POW ER IN SW 1 SW 2 SW 3 MU T E AL M
AL M AL M
PMU
PDU PDU
1 2 5 7 8 12
1 PDU board 7 TEST switch
2 RUN and ALM indicators on PDU 8 MUTE switch
3 Protection grounding screws 9 ALARM interface
4 Input cable terminals 10 SERIAL interface
5 Three power distribution switches 11 PMU
6 Output cable terminal 12 RUN and ALM indicators on PMU
2.1 Cabinet
2.2 Subrack
1. Interface Area
2. Air damper
3. Ventilation Tunnel
4. Board Area
5. Fiber Spool
6. Fiber Outlet Area
7. Fan Tray (with air filter)
8. Front Door
9. Hook
Subrack Dimension:
13 Slots in sub-rack
Slot 7 for SCC/SCE Board only
Fibers outlet from board panel
I I I I I I I I I I I I I
IU1~IU6, IU8~IU13: 38mm wide
U U U U U U U U U U U U U
IU7:24mm wide
1 2 3 4 5 6 7 8 9 1 1 1 1
OCU sequence when use external
clock sources: 0 1 2 3
IU12→IU10→IU8→IU5→IU3→IU1 S
The PBU card should be inserted in C
IU1 C
The OCP card should be inserted in /
IU2 or IU13 S
TC1/TC2/SC1/SC2 should be
C
inserted in IU6 or IU8 E
Optical fiber
wiring area
Fan box
Air inlet
2.1 Cabinet
2.2 Subrack
HUB
Accommodate 2 Hubs at most.
Power is supplied to the Hubs
from the power box.
Chapter 3 Cards
OTU O O OTU
M A
OTU / OLA / OTU
O O
OTU A D OTU
SDH SDH
PDH PDH
FE FE
GE GE
10GbE OCh 10GbE
OTU ATM
ATM OTU
ESCON ESCON
FICON FICON
FC FC
FDDI FDDI
D1 Video D1 Video
B1(B2), J0 monitoring
ITU-TG.692
ITU-TG.691 Performance/Alarm ITU-TG.694.1
ITU-TG.957 ALS function ITU-TG.709
IEEE802 series
3R function FEC/AFEC
SAN
ESC function
ATM
Channel spacing
850nm/1310nm
(50GHz/100GHz/200GHz)
/1550nm
NRZ/Super WDM
Tunable OTU
Client
OTU DWDM
10.71Gbps/AFEC 2.5Gbps
10GE LBE 4xAny AP4
10.71Gbps/FEC 10.71Gbps/FEC
LRF
10.71Gbps/AFEC 10.71Gbps/AFEC
TMR
Regeneration OTU 2.67Gbps/FEC 2.67Gbps/FEC
TRC
10.71Gbps/FEC/SuperWDM 10.71Gbps/FEC/SuperWDM
LRFS
10.71Gbps/AFEC/SuperWDM 10.71Gbps/AFEC/SuperWDM
TMRS
Performance
and alarm
Client side monitoring WDM side
STM-64 G.694.1
Optical transponder module
STM-64 G.694.1
CPU
Mailbox
SCC board
Performance
and alarm
monitoring
WDM side WDM side
CPU
Mailbox
SCC board
TMX
RUN
Rx OUT
ALM
O
IN OUT
Client WDM side
T
Rx1
Tx1
Rx2 side
Tx2
Tx IN
U
Rx3
Tx3
Rx4
Tx4
Off No alarm
n
n
n
n
n
1
Optical inputs
2
OUT
MUX Splitter
40 MON
Optical
module
Control and
SCC communication Electrical
circuit module
1
Optical inputs
2
OUT
V40
MUX Splitter
RUN
40 MON ALM
Optical
module
M07 M08 M09 M10 M11 M12 M13 M14
Control and
M23 M24 M25M26 M27 M28 M29 M30
MON D40
Optical i 1
RUN
DEMUX
signals
Optical
40
module D07D08 D09 D10 D11D12 D13 D14
MR2
ALM
IN MO A01 A02
OUT MI OUT MO
IN MI
A01 A02
ODD TO
50 GHz ITL
Interleaver OAU
100 GHz IN
RUN
ALM
EVEN TE
ITL
TE RE
ODD RO TO RO
50 GHz
100 GHz Interleaver OAU
IN OUT
OUT
EVEN RE
TMB TM
TC 1625nm C-band
RUN RUN WDM
ALM
C/L IN RUN RUN
WDM
ALM
TL L-band ALM ALM
IN OUT IN OUT
RL L-band splitter IN OUT IN OUT
TC RC TC RC
WDM C/L OUT
TC RC TL RL
RC C-band WDM TM RM
WDM
TL RL TL RL TM RM
TM RM TM RM MON
1625nm
1510nm
TMB RMB
RMB RM
Width of
Board Name Full name front panel
classification
(mm)
OAU
RUN
ALM
1 2 5 3 4 OUT
MON
PA BA
BA
IN VOA MON IN OUT TDC RDC
TDC RDC
Driving/
Optical Spectrum MCA
Control
Analysis Module RUN
Circuit ALM
R01 R02
CPU
R03 R04
R05 R06
Mailbox
R07 R08
SCC
Functional block diagram of MCA
FMU
MWA MWF
Board Full name Width of Slot
RUN
RUN RUN
name front panel
ALM
ALM ALM
(mm)
LIN1OUT1
IN1 OUT1
FMU Fiber Measure Unit 114 IU1 – IU4,
TS1 RS1
Board IU8 – IU11
RFM1 RFM2
MWA Measure Wavelength 38 IU1 – IU6,
TFM1 TFM2
Access Board IU8 – IU13
LIN2 OUT2
TS2 RS2
TFM3 TFM4
MWF Measure Wavelength 38 IU1 – IU6,
Filter Board IU8 – IU13
RFM3RFM4
MWF
MWF
MWA
FMU
Application of OAMS in the system (on-line monitoring)
RFM1
ALM ALM
success Cards
Chapter 3 Cards
RX1 TX1
Client side
Client side
OCP
RX2 TX2
Coupler Optical Tx Optical Rx Coupler RUN
Optical Optical
switch switch OUT1OUT2 OUT3OUT4OUT5OUT6
Control circuit
OUT7OUT8 IN1 IN2 IN3 IN4
Control
SCC Mailbox CPU circuit
module IN5 IN6 IN7 IN8
8 output channels
Rx3 Tx3
8 input channels
Rx5 C 4 4 C Tx5
Rx6 P 0 0 P Tx6
Rx7 Protection channel Protection channel Tx7
Rx8 Tx8
TP Rx OUT 9 9 IN Tx RP
OTU OTU
RUN
ALM
RI11 TO11 RI12 TO12 RI21 TO21 RI22 TO22 TO11 RI11
TO21 RI21
TO22 RI22
TO1 RI1
OUT TI Dual-fed Selection RO IN
module module
TO2 RI2
F Protection F
I I
U Working U
RI1 TO1
IN RO Selection Dual-fed TI OUT
module module
RI2 TO2
Protection
5V
-48V
Power switching 3.3V
OTU
module -5.2V
Voltage detection
module
CPU
Mailbox SCC
Cards
Equipment Protection