Professional Documents
Culture Documents
Resistivity LOG
Resistivity LOG
RESISTIVITY
LOG
Resistivity Applications
Schlumberger Private
Determine the quantity of hydrocarbon material
that exists (if porosity is known) through Archie's
equation.
Determine mud resistivity to help define the
invasion profile.
2
Resistance vs. Resistivity
Schlumberger Private
3
Material Resistivities
Schlumberger Private
Silver 1.59 x 10-8
-8
Bismuth - Tin 400 x 10
10
Dielectrics > 10
8
Marble 5 x 10
14
Quartz 3 x 10
14
Petroleum 2 x 10
4
Measuring Resistivity
V - Voltage (Volts) R - Resistance (Ohms)
I - Current (Amperes) A - Area (Square Meters)
L - Length (Meters) r - Resistivity (Ohms
Schlumberger Private
Meters)
K : Geometrical factor
5
Resistivity
Schlumberger Private
Resistivity of the salt water is Resistivity of the Oil is high
low ( highly conductive ) ( Poor conductor )
Resistivity
Schlumberger Private
Dry, nonmetallic minerals (rock matrix) have a very high resistivity
Resistivity
Schlumberger Private
The resistivity of a rock will depend on the conductivity of
the fluids saturating the porous volume
Common formation Resistivities
Schlumberger Private
Formation type Resistivity Range (ohm-m)
Soft Formations - shaley sands 0.2 to 50
Hard Formation - carbonates 100 to 1000
Evaporites - salt and anhydrite > 1000
9
Resistivity Logs
Schlumberger Private
Induction logs: run in nonconductive or low-conductivity
muds
Laterologs: run in highly conductive muds (salt based)
Resistivity Tool Limitations
Schlumberger Private
Rt (ohmm)
100
Recommended AIT AIT
operating Range and/or
HRLA
10
HRLA
1950
Schlumberger Private
Induction (IES)
Dual Induction (DIT-B)
Dual Laterolog 1960
Spherically Focused Laterolog
Dual Induction (DIT-D) 1970
Dual Induction - Phasor (DIT-E)
Array Induction 1980
AIT-B
Platform Express (AIT-H) 1990
1995
AIT-H Features
Five depth of investigation
10, 20, 30, 60 and 90”
Vertical resolutions
1, 2 and 4ft
Schlumberger Private
Real time borehole corrections
Built in Rm Sensor
Caliper input from PEX
Real time data quality Monitoring
Invasion Profiling
Model-based Rt and Rxo measurements
SP within the Rm Sensor
Logging speed: 3600ft/hr
AIT-H Specifications
• Name: AIT-H
• Length: 16ft
• Diameter: 3 7/8”
Schlumberger Private
• Borehole size: 4 3/4” - 20”
• Single Frequency: 26.325 khz
• Compatibility: standalone or Platform
Express
• Bottom only tool
• Max Temp: 257 degF
• Max. pressure: 10,000 psi (15k mod)
• Built - in SP sensor
• Built - in Rm sensor
• Other tools – Xtreme AIT / Slim AIT
Induction Theory
Transmitter creates
Magnetic field
• This creates a ground loop
Schlumberger Private
• The ground loop current
also creates a magnetic
field
• This field is picked up by
the receiver
AITH Outputs
AHT
20
Schlumberger Private
AHT20
Tool type:
AITH 20” depth of
investigation
Schlumberger Private
AHF30, AHF60,
AHF90
Two Foot curves:
AHT10, AHT20, 2’
AHT30, AHT60,
AHT90
One Foot curves:
AHO10, AHO20,
AHO30, AHO60,
AHO90 1’
Rm Calibration
Schlumberger Private
12 in. min
diam
Plastic tank
Master Calibration
Schlumberger Private
Winch
12 ft
4 ft
To be performed every 3 months or 20 jobs
Wellsite Calibrations
• Electronics Check
• Check master
calibrations for:
Schlumberger Private
– expired
– out of tolerance
– missing
Known Response
Permeable Zone
Example: sand
Schlumberger Private
Impermeable Zone
Example: shale
0.2 m 2000
Laterolog
Principle:
Schlumberger Private
Measuring the
voltage difference
between two electrodes is
the fundamental idea
behind laterolog devices.
Invasion
Resistivity profile is the
radial distribution of resistivity
resulting from the invasion of
fluids having different conductivity
Schlumberger Private
than the formation fluids .
Resistivity Profiles
Depth of Investigation:
Logging tools are designed
Schlumberger Private
to measure resistivity at different
depths radially from the wellbore to
determine the resistivity of the
flushed zone and the virgin zone.
Example Log With Resistivity
001) BONANZA 1
GRC ILDC RHOC DT
0 150 0.2 200 1.95 2.95 150 us/f 50
SPC SNC CNLLC
-160 MV 40 0.2 200 0.45 -0.15 ILDC
ACAL MLLCF
6 16 0.2 200 0.2 200
10700
Schlumberger Private
SNC
0.2 200
MLLCF
0.2 200
10800
10900
Resistivity
Log