Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 29

SmartGen ATS Control Modules

Company Profile

Started product research and development in 1998, Established in


2003
Address: Zhengzhou, Henan, China
Registered Capital: RMB 85 million
Staff Size : 300 +
Listed on NEEQ (stock code: 430504)
ATS Control Modules

HAT160 Series

HAT500 Series

HAT600 Series

HAT800 Series
HAT160 ATS Control Modules

HAT160 ATS Control Module is suitable for CB ATS of single motor. It can detect 2-way voltage
and judge voltage abnormal, then control ATS after delay. When ATS switch abnormally, the co
ntrol module can detect close/open failure and alarm on the front panel to ensure the correct act
ion of ATS. After abnormal of I# power, the control module will send signal to start the genset.

Performance and Characteristics


with voltage abnormal judge fuction
(such as over voltage, under voltage, close/open failure alarm ; LED display work status
01 over frequency, under frequency and l
02 03
ack of phase)

Auto/Manual mode. In manual mode, A “1# Priority, 2# Priority, No Priority Automatic Re-closing
04 TS can be switched by pressing front p 05 can be set via panel buttons; 06
anel button
With a forced breaking input port
Any one way of A phase voltage is n ( Fire reset interface. ) When
07 Close delay, delay is 0.5s 08 ormal, the control module and ATS c 09 the input port is enabled, ATS will
an normally work. automatically transfer to Breaking
(OFF) Position
Installation of HAT160 ATS Control Modules

Vertical Type
HAT5XX Series ATS Control Modules

HAT520N HAT530N HAT553


HAT500 ATS Control Modules

HAT530N ATS control


HAT520 ATS control
module is suitable for
module is suitable for
NO Breaking ATS and
NO Breaking ATS.
ONE Breaking ATS.

FUNTIONS
Measure and display 2-way 3 Over/under voltage, loss of phase, phas
Parameters can be set via P
01 phase Voltage and Frequenc 02 e sequence wrong, over/under frequency 03 C software
y protection function
The voltage normal/abnormal the Genset start /stop delay can Parameter configuration
04 delay of 1# or 2#can be set
05 be set
06 priority can be set via controller
front panel
Closing output signal can be set as Switch switch can be implemented vi
07 on intervals or as continuous output
08 a panel pushbutton 09 Auto/Manual mode

Forced Open input port is designed The output contact capacity of 1# and Suitable for 3-phase 4-wires, 2-ph
10 with HAT530; When the input port is a 11 2# power supply transfer relay is 5A, 12 ase 3-wires and single-phase 2-wi
ctive, the switch will be breaking positi which can be directly used in driving re
on forcedly switch to transfer
HAT553ATS Control Modules

Suitable for NO Breaking ATS 、


ONE Breaking ATS and TWO Breaking ATS

Performance
Performanceand
Performance andCharacteristics
and Characteristics
Characteristics

02
01 AC System :1P2W/2P3W/3P4W 02
02 Applicable Switch Type : Two-stage 、 Three-stage

03 Programmable Interface : 04
04 Even Log: 50 Records
RS485

05 Scheduled Start Genset: Monthly/Weekly 06


06 Language: Chinese &English
HAT600R ATS Control Modules
HAT600R ATS Control Modules
HAT600R ATS Control
Modules

Perormance and Characteristics

Genset In-
Voltage ABS
Schedule Phase
Sensing

Over
Auto/ Frequency
/Under IoT
Manual Sensing
Hz Ready

200
Black Event Alarm IP 65
Box Log History
HAT800 Series Control Modules

HAT821 HAT832 HAT833


suitable for two power supply + bus control three-way power supply (dual ATS control ) Suitable for three power supply three circuit breaker control

Performance and Characteristics

Chinese/English operating With NEL load tripping function


01 02 03 With key lock, fault lock function

With functions of oil engine starting output, Current continuous power supply time and
04 dispatching operation, cycle starting, balan 05 With forced breaking function
06 cumulative S1/S2 power supply time
ced starting

Measure and display two - way three- Measure and display the load active po With independent overcurrent warnin
07 phase voltage, frequency and phase 08 wer, reactive power, apparent power, p 09 g or tripping alarm function
ower factor and current

With the display of cumulative active en For energy storage switches, switch PF (r With overvoltage, undervoltage, loss
10 ergy, cumulative reactive energy and cu 11 eady to close) signal available before clos 12 of phase, inverse phase sequence o
mulative closing times ing verfrequency, underfrequency fun
ction
HAT821 Dual Power Bus Tie Control Module
HAT821 Dual Power Bus Tie Control Module

Breaker and
Power Status S1/S2 Master S1 Master S2 Master
Load Status
Status IOI Status IIO Status OII
QS1 Close QS1 Close QS1 Open
S1 Normal Breaker Status
QTIE Open QTIE Close QTIE Close
S2 Normal QS2 Close QS2 Open QS2 Close
S1 Supply LOAD1 S1 supply LOAD1 and S2 Supply LOAD1 and
Load Status
S2 Supply LOAD2 LOAD2 LOAD2

S1 Normal Breaker Status Status IIO 、 QS1 Close 、 QTIE Close 、 QS2 Open
S2 Abnormal
Load Status S1 Supply LOAD1 and LOAD2

S1 Abnormal Breaker Status Status OII 、 QS1 Open 、 QTIE Close 、 QS2 Close
S2 Normal
Load Status S2 Supply LOAD1 and LOAD2
S1 Abnormal Breaker Status Status OOO 、 QS1 Open 、 QTIE Open 、 QS2 Open
S2 Abnormal
( With under volt trip Load Status LOAD1 and LOAD2 Power off
function )
HAT821 Dual Power Bus Tie Control Module

S1 Power In S2 Power In MCH: Stored Engergy Motor


MN:Under Voltage Trip
MX: Open Relay
XF: Close Relay

MCH :储能电机;
MN :欠压脱扣;
MX :分闸线圈;
XF :合闸线圈;

ATS Control Module


HAT832 Three Power ATS Control Module ( Dual- ATS)
HAT832 Three Power ATS Control Module ( Dual-
ATS)
HAT832 Three Power ATS Control Module ( Dual-ATS)
HAT833 Three Power ATS Control Module
HAT833 Three Power ATS Control Module
HAT880 BYPASS ATS Controller
HAT880-Measure & Display1/2

Measure & Display Data Item 1


Load 3-Phase Reactive Power
S1/S2 Power Phase Voltage
kvar

S1/S2 Power Line Voltage Load Total Reactive Power kvar

Load 3-Phase Apparent Power


S1/S2 Power Voltage Phase
kVA

S1/S2 Power Frequency Load Total Apparent Power kVA

Load 3-Phase Current Load 3-Phase Power Factor PF

Load 3-Phase Active Power kVA Load Average Power Factor PF

Load Total Active Power kW Continuous Power Supply Time


HAT880-Measure & Display2/2

Measure & Display Data Item 2


Continuous Power Supply
MS1Total Close Times
Time
S1 Total Power Supply Time MS2 Total Close Times

S2 Total Power Supply Time BPS1Total Close Times

S1 Total kW Energy kWh BPS2 Total Close Times

S2 Total kW Energy kWh Input/Output Port Status

S1 Total kvar Energy kvarh Real Time

S2 Total kvar Energy kvarh Event Log


Black Box Records Communication Status
HAT880-Gen-Gen Start/Stop Mode

 Manual Start/Stop
 Remote Start/Stop ( RS485 , MODBUS Protocal )
 Auto Start/Stop
 Scheduled Start/Stop (day/week/month)
 Cycle Start/Stop
 Balance Start/Stop
 Master-slave Start/Stop
 Scheduled Run
 Scheduled Not Run (day/week/month)
HAT828 High-Speed ATS Controller
HAT828 High-Speed ATS Controller
HAT828 High-Speed ATS Controller

HAT828 High Speed ATS Controller is a dual power transfer module that can output
switch transfer signals within 10ms in the case of any power outage, and
synchronously transfer when both power supplies are normal. It is suitable for PC
two-stage transfer switch (high speed and normal). With embedded operation system,
it can precisely detect 2-way 3-phase voltage and make accurate judgment for
voltage abnormal situation (over voltage, under voltage, over frequency, under
frequency, loss of phase, reverse phase sequence). It also has configurable
input/output, LCD display, digital communication and other functions.
HAT828 High-Speed ATS Controller
Thanks!

You might also like