HAT160 ATS Control Modules
HAT160 ATS Control Module is suitable for CB ATS of single motor. It can detect 2-way voltage
and judge voltage abnormal, then control ATS after delay. When ATS switch abnormally, the co
ntrol module can detect close/open failure and alarm on the front panel to ensure the correct act
ion of ATS. After abnormal of I# power, the control module will send signal to start the genset.
Auto/Manual mode. In manual mode, A “1# Priority, 2# Priority, No Priority Automatic Re-closing
04 TS can be switched by pressing front p 05 can be set via panel buttons; 06
anel button
With a forced breaking input port
Any one way of A phase voltage is n ( Fire reset interface. ) When
07 Close delay, delay is 0.5s 08 ormal, the control module and ATS c 09 the input port is enabled, ATS will
an normally work. automatically transfer to Breaking
(OFF) Position
Installation of HAT160 ATS Control Modules
Vertical Type
HAT5XX Series ATS Control Modules
FUNTIONS
Measure and display 2-way 3 Over/under voltage, loss of phase, phas
Parameters can be set via P
01 phase Voltage and Frequenc 02 e sequence wrong, over/under frequency 03 C software
y protection function
The voltage normal/abnormal the Genset start /stop delay can Parameter configuration
04 delay of 1# or 2#can be set
05 be set
06 priority can be set via controller
front panel
Closing output signal can be set as Switch switch can be implemented vi
07 on intervals or as continuous output
08 a panel pushbutton 09 Auto/Manual mode
Forced Open input port is designed The output contact capacity of 1# and Suitable for 3-phase 4-wires, 2-ph
10 with HAT530; When the input port is a 11 2# power supply transfer relay is 5A, 12 ase 3-wires and single-phase 2-wi
ctive, the switch will be breaking positi which can be directly used in driving re
on forcedly switch to transfer
HAT553ATS Control Modules
Performance
Performanceand
Performance andCharacteristics
and Characteristics
Characteristics
02
01 AC System :1P2W/2P3W/3P4W 02
02 Applicable Switch Type : Two-stage 、 Three-stage
03 Programmable Interface : 04
04 Even Log: 50 Records
RS485
Genset In-
Voltage ABS
Schedule Phase
Sensing
Over
Auto/ Frequency
/Under IoT
Manual Sensing
Hz Ready
200
Black Event Alarm IP 65
Box Log History
HAT800 Series Control Modules
With functions of oil engine starting output, Current continuous power supply time and
04 dispatching operation, cycle starting, balan 05 With forced breaking function
06 cumulative S1/S2 power supply time
ced starting
Measure and display two - way three- Measure and display the load active po With independent overcurrent warnin
07 phase voltage, frequency and phase 08 wer, reactive power, apparent power, p 09 g or tripping alarm function
ower factor and current
With the display of cumulative active en For energy storage switches, switch PF (r With overvoltage, undervoltage, loss
10 ergy, cumulative reactive energy and cu 11 eady to close) signal available before clos 12 of phase, inverse phase sequence o
mulative closing times ing verfrequency, underfrequency fun
ction
HAT821 Dual Power Bus Tie Control Module
HAT821 Dual Power Bus Tie Control Module
Breaker and
Power Status S1/S2 Master S1 Master S2 Master
Load Status
Status IOI Status IIO Status OII
QS1 Close QS1 Close QS1 Open
S1 Normal Breaker Status
QTIE Open QTIE Close QTIE Close
S2 Normal QS2 Close QS2 Open QS2 Close
S1 Supply LOAD1 S1 supply LOAD1 and S2 Supply LOAD1 and
Load Status
S2 Supply LOAD2 LOAD2 LOAD2
S1 Normal Breaker Status Status IIO 、 QS1 Close 、 QTIE Close 、 QS2 Open
S2 Abnormal
Load Status S1 Supply LOAD1 and LOAD2
S1 Abnormal Breaker Status Status OII 、 QS1 Open 、 QTIE Close 、 QS2 Close
S2 Normal
Load Status S2 Supply LOAD1 and LOAD2
S1 Abnormal Breaker Status Status OOO 、 QS1 Open 、 QTIE Open 、 QS2 Open
S2 Abnormal
( With under volt trip Load Status LOAD1 and LOAD2 Power off
function )
HAT821 Dual Power Bus Tie Control Module
MCH :储能电机;
MN :欠压脱扣;
MX :分闸线圈;
XF :合闸线圈;
Manual Start/Stop
Remote Start/Stop ( RS485 , MODBUS Protocal )
Auto Start/Stop
Scheduled Start/Stop (day/week/month)
Cycle Start/Stop
Balance Start/Stop
Master-slave Start/Stop
Scheduled Run
Scheduled Not Run (day/week/month)
HAT828 High-Speed ATS Controller
HAT828 High-Speed ATS Controller
HAT828 High-Speed ATS Controller
HAT828 High Speed ATS Controller is a dual power transfer module that can output
switch transfer signals within 10ms in the case of any power outage, and
synchronously transfer when both power supplies are normal. It is suitable for PC
two-stage transfer switch (high speed and normal). With embedded operation system,
it can precisely detect 2-way 3-phase voltage and make accurate judgment for
voltage abnormal situation (over voltage, under voltage, over frequency, under
frequency, loss of phase, reverse phase sequence). It also has configurable
input/output, LCD display, digital communication and other functions.