Professional Documents
Culture Documents
1210 PiledRaftLayout 5H16
1210 PiledRaftLayout 5H16
1210 PiledRaftLayout 5H16
P1 to P15 -
300mm rotary pile
Client: Mr & Mrs Malde Drawing Title: Pile & Ground Slab Layout Drawing
Contract: Scale: NTS Drawn: JP Approved: Date:
17 Highview Gardens, Edgware, 20.10.20
HA8 9UB Drawing No.: JP0627//001 Rev: C0
Sheet 1 of 4
Main Steel:
Driven Pile
2H16 x 6m
Slab
50mm 250mm A393 mesh top and bottom
Gridding Bar:
5H16 top and bottom
Rebar cover:
Cellcore HX-S Sides = 40mm
5H16 top and
225mm thick Bottom = 50mm
bottom
Concrete:
Grade C28/35
Lap lengths:
Lap in mesh = 450mm
Lap in H16 bar = 650mm
220mm
driven
pile A393 Mesh top & bottom
Client: Below Ground Drawing Title: Pile & Ground Slab Layout Drawing
Contract: Scale: NTS Drawn: JP Approved: JP Date:
Richmond, Southampton Road, 03.08.21
Alderbury, Salisbury, Wiltshire Drawing No.: JP1210Sheet 1 of Rev: C0
SP5 3EB 2
Section A-A through the 800mm drop
450mm 250mm
800mm
450mm
2 Layers of H10 Z
bars spaced @
200mm centres
300mm
rotary
pile
Client: Mr & Mrs Malde Drawing Title: Pile & Ground Slab Layout Drawing
Contract: Scale: NTS Drawn: JP Approved: JP Date:
17 Highview Gardens, Edgware, 20.10.20
HA8 9UB Drawing No.: JP0627//001 Rev: C0
Sheet 3 of 4
Reinforcement Schematic
Client: Below Ground Drawing Title: Pile & Ground Slab Layout Drawing
Contract: Scale: NTS Drawn: JP Approved: JP Date:
Richmond, Southampton Road, 03.08.21
Alderbury, Salisbury, Wiltshire SP5 Drawing No.: JP1210/G/001 Rev: C0
3EB Sheet 2 of 2