Block A Block B Block C Block D Block E Block F Block G

No. of units 40 ( 10 per floor ) 40 ( 10 per floor ) 32 ( 8 per floor ) 32 ( 8 per floor ) 24 ( 6 per floor ) 24 ( 6 per floor ) 24 ( 6 per floor )
Type of unit 2BHK 2BHK 2 BHK( similar to Block 2 BHK ( similar to Block B ) 2.5 BHK 2.5 BHK 3 BHK
B)

Size of the 590 sq ft 613 sq feet ( Type 1) 620 sq. feet ( Type 1 ) 620 sq. feet ( Type 1 ) 635 sq. feet ( Type 1 ) 635 sq. feet ( Type 1380 sq. feet ( Type 1 )
Unit 632 sq feet ( Type 2) 638 sq. feet ( Type 2 ) 638 sq. feet ( Type 2 ) 694 sq. fee ( Type 2 ) 1) 1403 sq. feet ( Type 2 )
694 sq. fee ( Type 2 )

No. Of 1 – width ( 1.2m ) 1 – width ( 1.2m ) 1 – width ( 1.2m ) 1 – width ( 1.2m ) 1 – width ( 1.2m ) 1 – width ( 1.2m ) 1 – width ( 1.2m )
staircase

Lift 1 ( capacity 10) 1 ( capacity 10) 1 ( capacity 8) 1 ( capacity 8) 1 ( capacity 8 ) 1 ( capacity 8 ) 1 ( capacity 6 )

Corridor Width – 1.5 m Width – 1.5 m Width – 1.5 m Width – 1.5 m Width – 1.5 m Width – 1.5 m Width – 1.5 m

Parking It is provided at the It is provided at the It is provided at the stilt It is provided at the stilt It is provided at the stilt It is provided at the It is provided at the
stilt level. stilt level. level. level. level. stilt level. stilt level.
N0. of car parking – N0. of car parking – N0. of car parking – 32 N0. of car parking – 30 N0. of car parking – 25 N0. of car parking – N0. of car parking –35
21 40 Electrical room is Electrical room and security Electrical room is 25 Electrical room Electrical room and
N0. of 2 wheelers N0. of 2 wheelers provided at the stilt stay room is provided at the provided at the stilt and DG room is Association room is
parking – 18 parking – 22. level. stilt level. level. provided at the stilt provided at the stilt
Electrical room is Electrical room and level. level.
provided at the stilt maintenance room is
level. provided at the stilt
level.

Positive The entry for each Dining space is placed Dining space is placed Dining space is placed near The arrangement of The arrangement of Dining space is placed
aspect unit is not opposite near to the balcony, near to the balcony, to to the balcony, to get spaces in this unit is spaces in this unit is near to the balcony, to
to the neighbour, to get outside view get outside view while outside view while eating. better than the previous better than the get outside view while
which gives privacy while eating. eating. ones. previous ones. eating.
for the tenants.
Negative The Dining space in No natural light entry No parking for 2 No parking for 2 wheelers No parking for 2 No parking for 2 No parking for 2
aspect the unit is placed within the corridor. wheelers are provided. are provided. As well the wheelers are provided. wheelers are wheelers are provided.
opposite to As well the similar similar problem addressed As well the similar provided. As well the As well the similar
washroom, which problem addressed in in Block B problem addressed in similar problem problem addressed in
may be Block B Block B addressed in Block B Block B
uncomfortable for
the users.