Case Study Nasaria

You might also like

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 20

CASE STUDY &

LITERATURE STUDY
(RESIDENTIAL CUM COMMERCIAL
BUILDING)

BY :
HARSH RAJ (BARCH/10030/20)
SANJEEV KUMAR (BARCH/10033/20)
CASE STUDY
NARSARIA TOWER, RANCHI

2
INTRODUCTION

● Name of the Building: Narsaria Tower


● Period Of Construction: 2001-2006
● Architect: B.K Verma & Associates
● Builder: BABA Constructions
● Style Of Architecture: Contemporary
Architecture

3
LOCATION

● Location: Opp. Lalpur Thana, HB Road, Ranchi


● Site Accessibility:
1. Khadgara bus stand: 2.1km
2. Ranchi Railway Station: 3.4km
3. Birsa Munda Airport: 9.2km
● Present Status: All Occupied And Functional
4
CLIMATIC ASPECTS
● Climate : Composite, Tropical

● Ventilation :Adequate

● Rainfall: Monsoon is prolonged

● Humidity: It is moderate and mostly within


comfort zone

5
SITE DETAILS

● Topography: Of the site is almost even land

● Basement plan ● Bore Hole Location For Sub Soil


6
PLANS & SECTION

● Ground & 1st Floor Plan ● 2nd Floor Plan ● 3rd, 4th & 5th Floor Plan ● Section

7
CAR PARKING

● Residential car parking is given in the basement


● Total number of car parking provided: 15
● Commercial car parking is in the set back area.
● Total built-up area: 1616.46 sqm

8
OVERHEAD TANK
Requirement of water
● Flats
total no. of flats : 15
total no. of occupants for 5persons/flat= 75
total quantity of water required per day for
135L/person/day= 10,125L

● Commercial areas
Number of users: 160
Total quantity of water required per day
45L/Person/day: 7200L

● Total requirement of water per day: 17,325L


● Overhead water tank capacity: 20,000L

Water Filter on roof

9
SEPTIC TANK

● No. of users for flats: 75


● No. of users for
commercial areas: 50
● Total no. of users: 125
● Septic tank provided: 3 for
50 users each

10
INTERNAL FACILITIES PROVIDED

● Security:
1.Guard Room
2. Separate entry and exit for commercial and residential units
3. CCTV Cameras are provided in the commercial areas.
4. No CCTV found in residential areas.

● Electrical Duct: Visible on every floor(Size: 600mm x 1525mm)


● Garbage Chute: Not Provided
● Lifts: Separate for Commercial and residential units
Residential: (1625 x 1625)mm
Commercial: (1625 x 1625)mm
● Fire escape staircase: Provided: (600mm Wide)

11
Commercial Lift (1625x1625)mm Ramp: Only in basement

12
Sunk below lift to collect run-off water in basement

13
STAIRCASE DETAILS

Louvers in staircase Residential Staircase 1100mm(Wide)

14
FIRE ESCAPE

600mm(Wide)

15
FACILITIES & FEATURES PROVIDED

● Landscape: No landscaping features


● Air conditioning system: Individual as per requirement
● Sewerage System: Septic tank in setback
● Fire Protection: SOAK PIT
1. Complete fire protection and fighting system provided
2. Detection system provided
3. Fire fighting provision on every floor which can spray water up-to
60ft
4. Enough setback for fire truck
5. Emergency Staircase: 600mm
6. Fire extinguishers on every floor
7. Fire fighting water overhead tank of capacity 1lakh L
● Distance between Emergency staircase and main staircase:
6400mm

16
17
WATER HAVESTING

Water from terrace through pipes converging into


Provision for water harvesting is
main pipe recharging the ground water level
provided
18
SURROUNDING LAND ANALYSIS

On The Building Side

Opposite Of The Building 19


THANK YOU