PD Flow I – Floorplan

• Physical design is process of transforming netlist into layout


which is manufacture-able [GDS]. Physical design process is
often referred as PnR (Place and Route) / APR (Automatic Place
& Route). Main steps in physical design are placement of all
logical cells, clock tree synthesis & routing. During this process
of physical design timing, power, design & technology
constraints have to be met. Further design might require being
optimized w.r.t area, power and performance.
General Physical Design Flow is shown
below,
1. IMPORT DESIGN / NETLISTIN

• Import design is the first step in Physical Design. In this stage all required inputs &
required references are read into the tool. And also basic checks are done (design,
technology consistency).
Inputs required
1.Gate level netlist
2.Logical (Timing) & Physical views of standard cells & all other IPs used in the design
3.Timing constraints (SDC)
4.Power Intent (UPF / CPF)
5.FP DEF & Scan DEF
6.Technology file
7.RC Co-efficient files
How to qualify Import Design?

Check errors & warning while reading netlist. Understand all warnings
•Check for uniquification & empty modules
•Check errors & warning while reading timing constraints. Understand all
warnings
•Check errors & warning while reading UPF/CPF. Understand all warnings
•Timing QoR (Minimal violations with fixable WNS & TNS)
•Check MV Design (Equivalent to LP checks). Fix all errors & understand all
warning
•Check for assign & tri statements (Usually its checked & fixed after Synthesis)
• Timing analyses after Import Design
• It is always a good practice to do quick timing analyses after
import design. Even though post synthesis timing analyses is done
in timing tool (PT, Tempus/ETS), it’s better to check post
synthesis timing QoR in PnR tools also (ICC, Innovus, Olympus)
before actual implementation starts.
• Why it is required?
• CC/Innovus optimizes critical timing paths (violating paths)
which are seen by it. There can be chances that PnR tool is
showing a complete different timing QoR (huge violations)
compared to Post Syn QoR seen in PT/Tempus. It can be because
of correlation issue / constraints issue. We can avoid unnecessary
optimization; timing & design closure will be easy if we correlate
Import Design timing QoR with Post Syn timing QoR.
 FLOORPLAN

• Floorplan is one the critical & important step in Physical design. Quality of
your Chip / Design implementation depends on how good is the Floorplan. A
good floorplan can be make implementation process (place, cts, route &
timing closure) cake walk. On similar lines a bad floorplan can create all kind
issues in the design (congestion, timing, noise, ir, routing issues). A bad
floorplan will blow up the area, power & affects reliability, life of the IC and
also it can increase overall IC cost (more effort to closure, more LVTs/ULVTs)
• Before staring of Floorplan, it is better to have basic design understanding,
data flow of the design, integration guidelines of any special analog hard IPs
in the design. And for block/partition level designs understanding the
placement & IO interactions of the block in Full chip will help in coming up
with good floorplan.
• What is required to come with a good floorplan?
1.Basic design understating
2.Data flow diagram (DFA / Analyze logic connectivity in Synopsys ICC)
3.Integration guidelines
4.IO / Pin placement requirements
5.Special requirements from Full Chip floorplan
6.MV / LP requirements. Understanding of PDs & Vas
• Different types of partitions / blocks
1.Memory intensive digital cores, graphic cores
2.Partitions / Blocks with analog Hard IPs
3.DDR & other High Speed Interface partitions / blocks / sub-systems
4.Channel partitions
• Partitions with different critical tasks
1.Timing critical
2.Routing critical / Congestion
3.Blocks with complex Clock structure
• Types of floorplan techniques used in Full Chip plan
1.Abutted (All inter block pin connections are done through FTs)
2.Non abutted (Channel based. All inter block pin connections are
routed in channels)
3.Mix of both – partially abutted with some channels
FLOORPLAN STEPS
• Size & shape of the block (Usually provided by FC floorplan)
•Voltage area creation (Power domains)
•IO placement
•Creating standard cell rows
•Macro-placement
•Adding routing & placement blockages (as required)
•Adding power switches (Daisy chain)
•Creating Power Mesh
•Adding physical cells (Well taps, End Caps etc)
•Placing & qualifying pushdown cells
•Creating bounds / plan groups / density screens
Detailed discussion
• In multi-voltage & multi power domain designs, voltage areas
are required to guide the tool to understand different domains.
• There are two methods to create voltage area;
1.Abutted voltage area (Cells are not allowed to place in default
voltage area)
1. As is no default domain area, voltage area feed-through (VA-FT) are
required to cross over different voltage areas.
2.Non-abutted voltage area (Cells are allowed to place in default
voltage area)
• 1. Shape & size of the block / partition
• In most of the case, block size & shape is decided by FC floorplan.
Rectangle/Square shape is best in terms of floorplan & further design
closure. But in many case, floorplan can be of rectilinear shape with
many notches. It is always good practice to discuss with FC floorplan
team for any scope to improve block/partition level floorplan.
• 3. IO / Pin placement
• IOs / Pins are placed at the boundary of the block. Usually pin
placement information is pushed down from FC floorplan. But these
locations can be changed based on block critical requirements. Any
change in pin location has to be discussed with FC floorplan team.
Timing critical interfaces need special attention, like next 2-3 levels of
logic from IOs are pre-placed near the IOs). Source synchronous
interfaces requires delay balancing taking OCV into considerations
(This will require manual placement & scripting)
• Rows area created in the design using cell-site (unit / basic). Rows aid in
systematic placement of standard cells. And standard cell power routes done
considering rows.

Rows can be cut, wherever cell placement is not allowed OR hard placement
blockage can also be used.
• 5. Macro placement
• Step 1 – Understand Pins & Orientation requirements of Macros
• Step 2 – Follow data flow / hierarchy to place the Macros. Make
use of reference floorplan if available
• Step 3 – All the pins of the Macros should point towards the core
logic
• Step 4 – Channels b/w macros should be big enough to
accommodate all routing reqs & should get a minimum of one pair
VDD & VSS power grids in the channel
• Automatic Floorplan / Macro-placement
• Most of the PnR tools provide automatic floorplan option.
Automatic floorplan option creates its own macro placement based
on the effort & other options. But these options are not matured
enough to give optimum floorplan for all kind of designs. This
option will be handy, when design has 100s of Macros, but
generated floorplan needs lot of modification for further
optimizations
How to qualify Macro – Placement

•All macros should be placed at the boundary


•Check the orientation & pin directions of all macros
•Spacing b/w macros should be enough for routing & power grid
•Macros should not block partition level pins
•[Iterations] Less congestion & good timing QoR –These cannot be
achieved in one shot, but need few iterations [Thorough & deep
analyses are the key things while iterating]
6. Adding placement & routing blockages

• Buffer only blockages are added in channels b/w macros. Partial


placement blockages can be added b/w the channels blocking sequential
cells (whose placement in channels can degrade CTS QoR). Partial
blockages are added in congestion prone areas/notches/corners
• 7. Adding power switches
• Power switches are required to gate the power supply of gated domain
when not required. Power switches are MT-CMOS (multi-threshold)
cells, which will have very high threshold voltage when device is OFF &
very low threshold voltage when device is on.
• Power switches are inserted in power mesh & supply to all gated domain
cells will be through power switches. Hence a single / few switches are
not enough. A strong network of power switches connected in daisy
chain fashion will be inserted in the design.
8. Adding special cells (Well Taps, EndCaps, Spare Cells, Metal ECO-
able cells etc)

• Well connection – Almost all standard cell libraries are tap-less


(substrate connections are not done @ cell level). So Well-taps cells
are added in partition/chip level to tie the wells to VDD/VSS. Tap-
gate spacing has to be met while adding well-tap array.
• EndCap Cells – These cells are inserted to take care of boundary
DRC of Wells & Other layers. End Cap Cells ensure proper
terminations of rows, so that no DRC are created. This is a
physical-only cell.
• How to qualify Floorplan?
1.Check PG connections (For macros & pre-placed cells only)
2.LP / MV checks on floorplan database
3.Check the power connections to all Macros, specially analog/special
macros if any
4.All the macros should be placed at the boundary
5.There should not be any notches / thin channels. If unavoidable,
proper blockages has to be added
6.Remove all unnecessary placement blockages & routing blockages
(which might be put during floor-plan & pre-placing)
7.Check power connection to power switches
8.Check power mesh in different voltage area voltage area
9.Check pin-layers & check layer directions (H-V-H)