Professional Documents
Culture Documents
24B-Pactical Pipe Inspection 2006
24B-Pactical Pipe Inspection 2006
1 Welding Inspection
Pipe Inspection
Internal alignment
Time allowed 1 hour and 45 minutes Use your own code i.e. API 1104
Under fill
140
API 1104 B
40
12
98
Arc Strike
WELD FACE
DCode/Specification used:
180
20
15
90
10
Undercut
Under fill
60
Slag inclusion
Slag
Page 1 of 3
120
38
15
25
Arc Strike
Toe blend: Poor. Misalignment (HI-LO): 1mm Spatter or scale on the pipe surface
Cap height : 3mm. Weld width: 12-14mm Toe blend: Poor. Misalignment(HI-LO): 2mm Spatter or scale on the pipe surface Lack of side wall fusion
Cap height : 4mm. Weld width: 12-14mm Toe blend: Poor. Misalignment (HI-LO): 2mm Spatter or scale on the pipe surface
Cap height : 5mm. Weld width: 12-14mm Toe blend: Poor. Misalignment(HI-LO): 1mm Spatter or scale on the pipe surface
Burn through
140
40
180
20
15
90
10
Undercut >1.0 mm
46
Poor stop start Penetration height : 3mm. Misalignment (HI-LO): 2mm Spatter on the pipe surface Lack of root fusion
60
Penetration height : 5mm. Misalignment (HI-LO): 1mm Scale on the pipe surface
38
120
Smooth Undercut <1.0mm Penetration height: 2mm. Misalignment (HI-LO): 2mm Spatter on the pipe surface Penetration height: 3mm. Misalignment (HI-LO): 1mm Scale on the pipe surface
120
I C Plenty 001
Defects Noted Code or Specification Reference
Defect Type
Section/ Table No 4
7.8.2 7.8.2
Accept/Reject 5
Reject
Reject
Incomplete filling
22mm
None
7.8.2
Accept
N/A
70mm long 1.5mm depth 1.5mm 40mm 22mm 30x25
NONE
3mm
None 0.8mm 2mm NONE 25mm -----------------------
7.9.2
7.8.2 9.7.2 Table 4 9.3.9.3 9.3.10 9.3 Not specified
-----------
Accept
Reject Reject Accept Reject* Accept Reject**
Accept
-----------3mm ------------
----------7.2 ----------
Section/ Table No 4
7.2 Not specified 9.3.1 9.3.4 9.3.6 9.3.11 9.3.10 7.8.2 9.3.9.3 ----------
Accept/Reject 5
Accept Accept Accept Accept See Notes *** Accept Accept Reject Reject Accept
Misalignment Excessive Root Penetration Incomplete Root Penetration Lack of Root Fusion Root Concavity Root Undercut Cracks/Crack-like defects Slag inclusions Porosity Laps/Laminations
This *pipe/plate has been examined to the requirements of code/specification API 1104................. and is accepted/rejected accordingly. Comments: * Request MPI testing. ** Recommend arc strikes are ground flush prior to MPI testing for cracks. *** Radiography Required
Signature
2003
I C Plenty
Date
22nd August
Use the other side for any comments.
7.8.2
9.3.11
9.3.9
Copyright 2006, TWI Ltd
Any Questions
?
World Centre for Materials Joining Technology
Copyright 2006, TWI Ltd