Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 18

CE-441 B

PROBLEM- 2
The plan of a boundary wall is shown below. The 230 mm thick boundary
wall has RC pillars placed at 2.5m centre to centre to enclose the area
shown. The clear length of the opening is 5m
ESTIMATING QUANTITIES
Item NO. L (m) B H (m) Quan Uni Remarks
(m) tity t

Earthwork 1 60 1.3 1.2 93.60 m^3 L=10+20+10+20


B=0.9+0.2+0.2(EXT
RA 200MM ON
BOTH SIDES)
H=0.2+0.5+0.225+0.
2+0.075

Deductions 1 3.7 1.3 1.2 -5.77 m^3 Length of opening=5-


( opening) 2*0.65
(Clear spacing minus
half width of
excavation on both
sides)

TOTAL 87.83 m^3


CONTD..
ITEM NO. L(m B(m) H(m) QTY UNIT REMARKS
) . S
RC pillar 23 0.2 0.3 2.675 4.25 M^3 H=1.8+0.875
3
RC 23 0.8 0.8 0.25 3.68 M^3
footings
Total RC 7.93 M^3

PCC 1 60 0.9 0.075 4.05 M^3 L=10+20+10+20

Deduction
s
Opening 1 4.1 0.9 0.075 - M^3 L=5-(2*0.45)
0.27 Clear spacing minus half width of
pcc on both sides
Total PC 3.78 M^3
ITEM NO. L(m) B (m) H (m) QTY. UNI REMARKS
T
Brickwork 22 2.2 0.23 2 22.26 m^3 Length of each
block=2.5-0.15-0.15
Total no blocks of 2.2m
length=22

Offset-1 22 2.2 0.4 0.5 9.68 ”

Offset-2 22 2.2 0.5 0.225 5.44 ”

Offset-3 22 2.2 0.6 0.2 5.80 ”

Deductions

Double 22 0.5 0.6 0.2 -1.32 ” At overlap,


overlap Length of double
overlap=800-
300=500mm

22 0.5 0.5 0.05 -0.275 ”

Total 41.59
Item NO L (m) B (m) H Qty. Unit Remarks
(m)
Plastering

Interior H=1.8+0.1(plaster
extends 100mm below
GL)
Long Wall 2 19.77 1.9 75.13 m^2 L=20-0.115-0.115

Short wall 2 9.77 1.9 37.12 ‘’ L=10-0.115-0.115

Exterior
Long wall 2 20.23 1.9 76.87 ‘’ L=20+0.115+0.115

Short wall 2 10.30 1.9 39.14 ‘’ L=10+0.115+0.115


Edges 3 0.23 1.9 1.31 ‘’ In evaluating the lengths,
the appropriate
thicknesses of pillars on
either sides are
considered.
Deductions

Opening 2 5 1.9 -19 ‘’

TOTAL 210.57
CONTD..
Item No. L (m) B (m) H (m) QTY. Unit Remarks

Shutterin
g
Pillar 23 1.06 2.675 65.21 m^2 Pillar
Diameter=(2*0.23)
+(2*0.3)

Footing 23 3.2 0.25 18.4 ” H=1.8+0.8


75
” Footing Length=
4*0.8=3.2

Total 83.61 ”

Barbed 4 55 220 m L=2*10+20


Wire +6*2.5
Reinforcement
Diamete Shape Cut No. Total Weight Total
r(m) weight
length Length in kg/m
(kg)
(mm) (m)
a
a b

12 a=100mm 920 322 296.24 0.888 263

B=720mm

Cut length = (800-2*40)+100+100


No of Spaces= {800-2*40-2*12-2*12/2}/100=6
No of bars per RC pillar and footing=2*(6+1)=14
Total no of bars= 23*14=322

*IS 1786:2008
CONTD..
Dia Shape Cut No. Total Weight Total wt.
(mm) (kg)
length length in kg/m
(mm) (m)
a

b
16 a=2825m 3075 138 424.35 1.58 670.5
m
b=250mm

a=1800+875+150=2825mm; b=250mm
Cut length= a+b=3075mm
No of bars per RC pillar=6
Total No of Bars =6*23=138
CONTD..
Dia Shape Cut No. Total Weight Total
(mm) weight
length length in kg/m
(kg)
(mm) (m)
Stirrups
L

B
8 L=212mm 900 391 351.9 0.395 139
B=142mm

As per IS 2502:1963, the total hook allowance for stirrups is 24*dia of stirrups
L= 300-(2*40)-8; B= 230-(2*40)-8
No of spacings = {(1800+875+150)/175} =16
No. of stirrups per RC pillar=16+1=17
Total no. of stirrups=23*17=391
🞂Total steel required in boundary wall construction=
263+670.5+139
=1072.5kg
■THANK YOU !!