Intelligent Security Protection System iSPY

Agenda

Power Monitoring Remote Access iSPY - Hardware iSPY - Software


Monitoring Maintenance Testing

Network Examples

Real Time Monitoring Benefits

Identify events as they occur Centralized access Efficient use of key personnel Lower costs Increased security

Real Time Monitoring - Dark Fiber

Laser Source

1xN Splitter

Power Meter

LS

iSPY Management Software


4

Real Time Monitoring - Dark Fiber with Loopback

Laser Source

1xN Splitter

Looped Fiber

LS

Power Meter

iSPY Management Software

Real Time Monitoring - Active Fiber

Power Meter RX1 TX1


1310 or 1550 nm

RX2 Power Meter

TX2

iTEST Management Software


6

Real Time Monitoring - Active Fiber with Loopback


Laser Source

1xN Splitter WDM WDM RX1


1310 or 1550 nm

LS

1625 nm 1310 or 1550 nm

TX1 RX2

WDM

WDM TX2
1310 or 1550 nm

1310 or 1550 nm

1625 nm

Power Meter
7

iSPY Management Software

OTDR Location Identification

Quickly identify location of events Centralized access Efficient use of key personnel Lower costs Increased security

Real Time Power Monitoring with OTDR location - Dark Fiber


Laser Source 1 N S litter Power Meter

LS
WDM

O T D R
1550 nm

1XN Switch

NTest Management Software


9

Real Time Power Monitoring with OTDR Location - Dark Fiber with Loopback
rS rc 1 N S litt r

S
WDM

Looped Fiber

O T D R
1550 nm

P w rM t r 1XN Switch

NTest Management Software


10

Real Time Power Monitoring with OTDR Location - Active Fiber

1310 or 1550 nm

TX

WDM

WDM Filter

Power Meter

1310 or 1550 nm

RX
O T D R
1625 nm

1XN Switch

NTest Management Software


11

Real Time Power Monitoring with OTDR Location - Active Fiber with Loopback
TX1
1310 or 1550 nm

1xN Splitter WDM WDM

Light Source
1625 nm

RX1
1310 or 1550 nm

1x2 switch
1310 or 1550 nm

1625 nm

O T D R
1625 nm

WDM

WDM TX2

RX2 1x2 switch


1310 or 1550 nm

1XN Switch Power Meter

1625 nm 12

Manhole/Cabinet Intrusion Detection and Location


rS rc 1 N S litt r

S
WDM

Sensors Looped Fiber

O T D R
1550 nm

P w rM t r 1XN Switch

NTest Management Software


13

iSPY - Hardware
Chassis Controller Laser Optical Power Monitor 1xN Switch 1x2, 1x4 Switch
14

OTDR

Chassis

Hot Swappable Modules plug into back-plane -48 VDC / 100-240 VAC Communications via RS232 or Ethernet Daisy chain multiple chassis (RS-485) 3U, 4U, 5U, 8U sizes

15

Controller

Provides communication between user and modules Controls operations of all modules through chassis back-plane Communications via RS232 or Ethernet Control through TL1, or GUI

16

iVAM 1550 nm Laser Source

1550 nm stable laser source Single mode -15 dBm power output after 1x16 splitter Reaches over 180 Km
17

1xN OTAU

OTAU is a Telcordia term for Optical Test Access Unit 1 x N or Dual 1 x N switch (1x4 to 1x130) Plugs into back-plane, controlled by controller module Switch between test fibers and test equipment Leverage OTDR over many circuits
18

Remote OTDR

Remote operation Plugs into back-plane One slot space 1310, 1550, 1625 nm 35-41.5 dB dynamic range

19

Optical Power Monitor (OPM)


4 and 8 channels Monitors power levels Able to set thresholds Alarms Range: +3 to -50 dBm (other ranges available) +/- 0.02 dB resolution +/- 0.2 dB accuracy 850, 1310, or 1550 nm Multimode and Singlemode NEBs qualified
20

iSPY - Software

Monitoring Testing

21

Monitoring
Real-time monitoring
Optical power measurements every 250 msec.

Set minor and major alarm thresholds Stores minimum and maximum power levels View current power level on any fiber Monitoring by dedicated power monitor modules
Maximizes OTDR life OTDR used for fault location

Stores alarm history


22

GUI Interface

23

GUI Alarm Threshold Setup

24

GUI No Alarms

25

GUI Alarm on Port 1

26

GUI Additional Read-Only View

NO ALARM

ALARM

27

GUI Alarm History Screen

28

Priority Alarm Location

29

Event Table

30

iSPY System Software


Multiple user administration levels
Each user has unique login and password Administrator full rights for user and system setup User - read-only, receive alarms, launch traces

Alarm history log


Stores all link status alarms and failures Stores both time of alarm and return to normal

Auto calibration
The server performs a regular system calibration Calibrates laser changes over time, temperature variations on fiber, etc.

Communication assurance
System sends a Heart Beat signal from server to all modules

31

Power failure alarm


Power failure alarm via dry-relay contacts

iSPY System Software

Client-Server Architecture Client and Server software run on Windows, Linux, Sun, Mac (anything that supports Java 1.5) Software can run on an existing server/computers Server uses 112 MB and client uses 105 MB Unlimited number of users HSQLDB database Hibernate ORM mapping allows mapping to other databases
32

Communications Diagram
10BaseT

LAN/WAN
10BaseT

iTEST Clients
10BaseT

10BaseT

Master Controller Master Controllers at multiple sites RS-485 Slave Controllers

iSPY Server
33

iSPY Intrusion Detection


A Ring Network Example

34

iSPY Fiber Optic Diagram Dark Fibers (Door Monitoring)

1x16 splitter

Light Source
1550 nm

Looped Fiber

Door Switch
Power Meter

35

iSPY Ring Network Example

32 L1 Loopback to 9

38 L1

9 O4-M3-L2 7 O2-M2 20 O4-M3 Two Fibers 12 O2M2 28 O2L2

Two Fibers 4 O4-L3

3 1x2S 2 W-F 36 OM1 1 O2-M2W 17 O2-M2 21 O2-M2W

26 O2M2 22 W-F

14 O2-L2

18 L3 23 O2-L2

1625 nm 40 dB OTDR 39.5 dB OTDR 36

1U Rack Mount- Power 3U Chassis- Power, Ethernet Mount 1U Rack 3MM Ruggedized

iSPY Ring Network Example

32 L1 9 O4-M3L2

38 L1

7 O2-M2 20 O4-M3 28 O2L2

12 O2M2

4 O4-L3 3 1x2S 2 WF 1 O2-M2W 18 L3 17 O2M2

26 O2M2 22 W21 O2-M2- F W

14 O2-L2

36 OM1

23 O2-L2

37

1625 nm 40 dB OTDR 39.5 dB OTDR

1U Rack Mount- Power 3U Chassis- Power, Ethernet 1U Rack Mount 3MM Ruggedized

Dark Fiber Real Time Monitoring


Power Monitor
1310 nm

WDM

SITE 1 SITE 2

1550 nm

1x2 splitter
To Next Site

O T D R
1550 nm

WDM Filter

1X2 Switch

1550 nm

Light Source
1310 nm

WDM Power Monitor


1310 nm

38

To Next Site

Active Fiber Real Time Monitoring


Power Monitor WDM

SITE 1 SITE 2

RX
1310/1550 nm 1625 nm

WDM Filters
To Next Site

O T D R
1625 nm

1X2 Switch

1625 nm

TX
WDM

TX

1310/1550 nm 1310/1550 nm

Power Monitor

RX
39 To Next Site

You might also like