ACI Paint and Coatings

All ABOUT PAINT AND COATINGS APPLICATION SERVICE

PT. Asia Chemical Industry


Marketing Office: Pasuruan Office :
Karawaci Office Park, Blok H, No. 25 Ruko Gempol Interchange, No.A11
Karawaci, Tangerang, Banten Jln. Raya By Pass Legok, Gempol, Pasuruan
Phone: 021-55790456 (Hunting) Telp & Fax : 034-3655320
Fax : 021-55790454
http://aci-yuwon-biz.com
PT.Asia chemical Industry is leading paint and coatings manufacturing .
Specialty and high performance product with balance cost create by
experienced ,experts and profesional research and development Team .
With detail and controling when process manufacturing resulted high quality end good
product as standard and customer specification .
With motto customer satisfaction for quality and delivered time , quick technical service
is our aim.we will support our customer get best end surfance product
A. Specialty PROTECTIVE
High termal / high temperature resistant paint

Primer :

1. Two comp zinc rich primer

. Recommended as primer coat Anti corosion primer for high termal /high temperature paint specialty for coating under insulation paint and
high corrosion in immersent atmosphere such us.
silicate

2. One comp Zinc rich silicate Primer

. Recommended as Anti corosion primer for high termal /high temperature paint specialty for coating under insulation paint.

3. Aluminium primer .HR.


one component styrene modified oxidatively drying alkyd coating. It is heat resistant up to 250 °C. Can
be used as an exterior aluminium finish usually within an alkyd system. Can be used as primer, mid coat or
finish coat in atmospheric environments.
PRODUCT DEVELOPMENT PLANNING.
D.High thermal/high temperature coatings
PRIMER

1A. ZINC RICH PRIMER ITEM   STANDARD


a two component moisture curing inorganic zinc ethyl silicate NV /SOLID CONTENT   68+/- 2
coating. It is a zinc dust containing product. FLAST POINT   14’C
It conforms to the compositional requirements of SSPC paint 20, GLOSSYNESS   MATT
level 3. It provides very good corrosion DENSITY   3,99
protection as part of a complete coating system. It is heat resistant VOC   588
up to 400 °C. To be used as primer in DRYING TIME SUBTRATE TEM 5 10 23 40 ‘C
PERATURE
atmospheric environments. Suitable for properly prepared carbon SURFACE DRY 60 30 15 13 MINUTE
steel substrates only. This product complies DRY ON WALK 90 45 30 25 MINUTE
with ASTM D520 type II zinc dust. Dry to over coat, 36 24 12 7 HOUR
Colours minimum
grey Dried/cured for 36 24 12 7
serviceAT
Typical use
DRY FILM THICKNESS 50-90UM
Protective:
WET FILM THICKNESS 75-130 UM  
Suitable for structural steel and piping to be exposed to corrosive
Theoretical spreading 13,6-7,6 M2/L
environments. Recommended for offshore  
rate
environments, refineries, power plants, bridges, buildings and
mining equipment. Designed as a primer in
coating systems where durability is required.
PRODUCT DEVELOPMENT PLANNING.
D.High thermal/high temperature coatings
PRIMER

2. ZINC SILICATE PRIMER ITEM   STANDARD


NV /SOLID CONTENT   42+/- 2
one component physically drying zinc rich silicone coating. It is heat
FLAST POINT   35 C
resistant up to 400 °C. Can be
GLOSSYNESS   MATT
used as primer in atmospheric environments. Suitable for properly
DENSITY   3,99
prepared carbon steel substrates.
VOC   249
Colours SUBTRATE TEM 5
DRYING TIME 10 23 40 ‘C
grey PERATURE
Typical use SURFACE DRY 60 30 15 MINUTE
Protective: DRY ON WALK 4 3 2 HOUR
Designed as heat resistant coating. Recommended as primer in Dry to over coat, 6 3 2 HOUR
combination with silicone topcoats, providing minimum
heat resistance up to 400 °C and corrosion protection.
DRY FILM THICKNESS 20 -50UM
WET FILM THICKNESS 20-120 UM  
Theoretical spreading 21-8,4 M2/L
 
rate
PRODUCT DEVELOPMENT PLANNING.
1.PROTECTIVE
B. High termal / high temperature resistant paint TOP COAT

1. High term silicone paint for 250 and 540 “C Resistant.

. Recommended as primer coat, monocote or topcoat for for high termal /high temperature paint specialty for coating under insulation paint
Available for ambien curing or stoving curing in 30 minute 242’c or 60 minute 205 ‘ccc

2. Inert multipolimeric matricx coatings

Recomendec as monocooat for wide temperature coatings for -40 up 600 ‘c especialy for coatings under solution ..

3.High temperature ceramic coatings .


Recomended as monocote for for high termal /high temperature paint specialty for coating under insulation paint for 1000’c resistant.
PRODUCT DEVELOPMENT PLANNING.
D.High thermal/high temperature coatings
Top coat

ITEM   STANDARD
a. High term 250 alu and colour
NV /SOLID CONTENT   34+/- 2
one component physically drying silicone acrylic coating. It is an
FLAST POINT   27 C
aluminium pigmented product. It is
GLOSSYNESS   MATT
heat resistant up to 260 °C. Can be used as primer, mid coat or finish
DENSITY   1
coat in atmospheric environments.
VOC   580
Suitable for properly prepared carbon steel, galvanised steel, stainless SUBTRATE TEM 5
DRYING TIME 10 23 40 ‘C
steel and aluminium substrates. PERATURE
Colours SURFACE DRY 45 30 15 10 MINUTE
Aluminium and black DRY ON WALK 4 3 2 1 HOUR
Typical use Dry to over coat, 6 3 2 1 HOUR
minimum
Protective:
Designed as heat resistant coating. Suitable for insulated and non DRY FILM THICKNESS 20 -40UM
insulated surfaces. Recommended in WET FILM THICKNESS 60-120 UM  
combination with an inorganic zinc silicate coating as primer, providing Theoretical spreading 17-8,5 M2/L
 
heat resistance up to 260 °C and long rate
corrosion protection.
PRODUCT DEVELOPMENT PLANNING.
D.High thermal/high temperature coatings
Top coat

ITEM   STANDARD
B. High term 540 alu
NV /SOLID CONTENT   40+/- 2
one component physically drying silicone acrylic coating. It is an
FLAST POINT   26 C
aluminium pigmented product. It is heat resistant up to 600 °C. Can be
GLOSSYNESS   MATT
used as primer, mid coat or finish coat in atmospheric environments.
DENSITY   1,14
Suitable for properly prepared carbon steel, galvanised steel, stainless
VOC   520
steel and aluminium substrates. SUBTRATE TEM 5
DRYING TIME 10 23 40 ‘C
Colours PERATURE
aluminium SURFACE DRY 60 45 30 15 MINUTE
DRY ON WALK 4 3 2 1,5 HOUR
Protective: Dry to over coat, 8 5 4 3 HOUR
Designed as a heat resistant coating. Suitable for insulated and non minimum
insulated surfaces. Recommended in
combination with an inorganic zinc silicate coating as primer, providing DRY FILM THICKNESS 20 -30UM
heat resistance up to 400 °C and long WET FILM THICKNESS 55-80 UM  
term corrosion protection. For shorter periods, such a combined Theoretical spreading 20-13,3 M2/L
 
system can handle peak temperatures up to rate
540 °C
PRODUCT DEVELOPMENT PLANNING.
D.High thermal/high temperature coatings
Top coat

ITEM   STANDARD
C. High term 540 colour
NV /SOLID CONTENT   42+/- 2
one component physically drying silicone acrylic coating. It is an
FLAST POINT   26 C
aluminium pigmented product. It is heat resistant up to 600 °C. Can be
GLOSSYNESS   MATT
used as primer, mid coat or finish coat in atmospheric environments.
DENSITY   1,3
Suitable for properly prepared carbon steel, galvanised steel, stainless
VOC   520
steel and aluminium substrates. SUBTRATE TEM 5
DRYING TIME 10 23 40 ‘C
Colours PERATURE
aluminium SURFACE DRY 60 45 30 15 MINUTE
DRY ON WALK 4 3 2 1,5 HOUR
Protective: Dry to over coat, 8 5 4 3 HOUR
Designed as a heat resistant coating. Suitable for insulated and non minimum
insulated surfaces. Recommended in
combination with an inorganic zinc silicate coating as primer, providing DRY FILM THICKNESS 20 -30UM
heat resistance up to 400 °C and long WET FILM THICKNESS 50-70 UM  
term corrosion protection. For shorter periods, such a combined Theoretical spreading 20-14 M2/L
 
system can handle peak temperatures up to rate
540 °C
PRODUCT DEVELOPMENT PLANNING.
D.High thermal/high temperature coatings
Top coat

ITEM   STANDARD
D. High term 650
NV /SOLID CONTENT   76+/- 2
a one component inert multipolymeric matrix coating. It is resistant to
low temperatures, down to -196 FLAST POINT   18 C
°C and high temperatures, up to 650 °C continuously, 720 °C GLOSSYNESS   MATT
intermittent. Can be used as primer or finish coat DENSITY   1,92
in atmospheric environments. Suitable for properly prepared carbon
steel and stainless steel substrates. It can VOC   464
DRYING TIME SUBTRATE TEM 10 15 23 40 100 ‘C
be applied on hot substrates up to 400 °C. PERATURE
Colours SURFACE DRY 600 360 120 120 30 MINUTE
grey, aluminium effect DRY ON WALK 24 24 6 4 1 HOUR
Typical use Dry to over 24 24 6 4 1 HOUR
Protective: coat, minimum
Specially designed for preventing corrosion under insulation (CUI).
Recommended at dry operating surface DRY FILM 100 -150UM
temperatures that can range from cryogenic, i.e. -196 °C, to above THICKNESS
650 °C (intermittent 720 °C). Suitable for insulated and non insulated WET FILM 135-200 UM
 
surfaces. THICKNESS
Theoretical spreading 7,6-5,1 M2/L
 
rate
PRODUCT DEVELOPMENT PLANNING.
D.High thermal/high temperature coatings
Top coat

ITEM   STANDARD
E. High term 1000 ceramic coat
NV /SOLID CONTENT   75+/- 2
two component titanium catalyzed inorganic ceramic copolymer. It
complies to the generic type Multi FLAST POINT   26 C
Polymeric Matrix Coating. It is resistant to low temperatures down to - GLOSSYNESS   MATT
196 °C and high temperatures up to 1000 DENSITY   1,8
°C continuously, where substrates allow. Can be used as primer or
finish coat in atmospheric environments. VOC   362
DRYING TIME SUBTRATE TEM 10 15 23 40 ‘C
Suitable for properly prepared carbon steel, stainless steel and PERATURE
ceramic substrates. On carbon steel and stainless SURFACE DRY 5,5 3 2,5 1,5 HOUR
steel substrates it can be used up to 650 °C continuously and 750 °C DRY ON WALK 24 18 6 3,5 HOUR
intermittent. It can be applied on hot Dry to over 24 18 6 3,5 HOUR
substrates up to 150 °C. coat, minimum
Typical use Dried cured for
service
Protective: DRY FILM 100 -150UM
Designed as a heat resistant coating. Suitable for insulated and non THICKNESS
insulated surfaces. Can be used in WET FILM 130-200 UM
combination with an inorganic zinc silicate coating as primer, providing  
THICKNESS
heat resistance up to 400 °C and long Theoretical spreading 7,5-5 M2/L
corrosion protection. For shorter periods, such a combined system can  
rate
handle peak temperatures up to 540 °C
PRODUCT DEVELOPMENT PLANNING.
D.High thermal/high temperature coatings
PRIMER

3. Aluminium HR PRIMER ITEM   STANDARD


NV /SOLID CONTENT   45+/- 2
one component styrene modified oxidatively drying alkyd coating.
FLAST POINT   36 C
It is heat resistant up to 250 °C. Can
GLOSSYNESS   Aluminium sheen
be used as an exterior aluminium finish usually within an alkyd
DENSITY   0,93
system. Can be used as primer, mid coat or
VOC   435
finish coat in atmospheric environments. Suitable for properly SUBTRATE TEM 5
DRYING TIME 10 23 40 ‘C
prepared carbon steel and aluminium substrates. PERATURE
Colours SURFACE DRY 30 30 15 15 MINUTE
aluminium DRY ON WALK 18 14 10 8 HOUR
Typical use Dry to over coat, 24 12 8 6 HOUR
Exhaust pipes, process piping and engine parts. minimum
Other
DRY FILM THICKNESS 20 -30UM
WET FILM THICKNESS 45-65 UM  
Theoretical spreading 22,5-15 M2/L
 
rate