Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 4

First Step

Extract information from stream data


• Two Streams
• Supply Temperature, Target
Temperature, Flow Rate and
Mean Heat Capacity
Second Step
• Detect cold/hot streams Proces stream

number Ts (oC) Tt (oC) Thermal capacity (KW/oC)
Calculate thermal capacity

C 1 100 135 40 kg/s x 2..5kJ/kgoC=100 KW/oC

H 2 200 70 10kg/s x 2..5kJ/kgoC=25 KW/oC


Third Step
Adjusted temperatures

Proces stream Thermal capacity Ts (oC) Tt (oC) Ts/Tt
Adding ½ DTmin to the cold stream
temperature
number (KW/oC)
• Subtracting ½ DTmin to the hot stream
temperature
C 1 100 100 110
135
145

H 2 25 200 190
70
60
Final Step
• Write adjusted temperature into the
Intervals column from highest to lowest
with no duplicated values

You might also like