GENESIS SERIES

“State Of Art” product developed by Citec


Adopting the most advanced and latest technology
GENESIS SERIES INTRODUCTION

• Full Modular Design


• Capacities Range :
15 kW to 110 kW
• Cooling Mode :
Air-cooled DX
Water Cooled DX
Chilled Water Cooled
• Air Flow Configuration :
Up Flow (Front Return)
Up Flow (Bottom Return)
Down Flow
• Full Function :
Cooling
Humidification
De-Humidification
Re-Heating
• Microprocessor Control
Internal Component Arrangement (Downflow, Air-Cooled)
Air Filters
Electronic Expansion
Valve
Coils

Electric Reheat
Controller
Display Fans
(Behind Electrical Panels)

Microprocessor Controller
Hinged Electric Panels

Humidifier Compressor
FEATURES
Modular Design

• The Genesis series is


constructed by combining
together blocks of single
modules of varying
capacities & sizes.
• There are basically 2 types of
modules :
A (model 15,18 & 20) &
B (model 25, 30 & 35)
• All models above 35kW of
capacity are actually
constructed by combining
multiples units of these 2
modules. Module B Module A
Modular Design
Example : GD40A

Module A Module A Module A x 2 nos


(20kW) (20kW) (40kW)
Modular Design
Example : GD60A

+ +

Module A Module A Module A Module A x 3nos


(20kW) (20kW) (20kW) (60kW)
Modular Design
Example : GD70A

Module B Module B Module B x 2nos


(35kW) (35kW) (70kW)
Modular Design
Example : GD55A

Module A Module B Module A + B


(20kW) (35kW) (55kW)
 Scroll Compressor  Direct Driven Fan

• Standard for all Genesis models • Direct Driven DIDW Centrifugal Fan is a
• High COP / EER standard for all Genesis models
• Low noise • TEFC motor
• More Reliable • No need for pulley & belt
• Reciprocating compressor is available as an option • More efficient than belt driven
 Electronic Expansion Valve (DX
system only)

• An integral part of the Genesis design


• Allows very precise control of the refrigerant flow
based on real-time feedback
• Faster response & wide modulating range ensure the
stability of the environment & provides energy saving
• With the presence of the temperature & pressure
probe, can easily detect any problem in the system
by checking the superheat & suction pressure from
display. No need for gauges.
 Coils
• ‘A’ Frame design (Downflow)
• ‘V’ Frame design (Upflow)
• Double condensate drip tray, intermediate &
bottom
• Special protection coating available as an
option

 Air Filters

• Disposable type
• EU4 or 35% eff. to ASHRAE 52/76 as standard
• EU7 High Efficiency Filter is available as an option
 Heater  Humidifier
• Electric Heater is standard for all • Steam Electrode Boiler is standard for all
Genesis models
Genesis models • Adjustable Steam Production
• Incoloy sheathed element with • Disposable Bottle
stainless steel finnings • Serviceable Humidifier is available as an option
• With over-heat protection
• LPHW is available as an option
 Electrical Panel  Chilled Water Modulating Valve
• All cables color coded and • 2-Way Modulating Valve is standard for
numbered all Genesis chilled water cooled models
• High & Low Voltages cablings • 3-Way Modulating Valve is available as
segregated in different an option
trunkings
Refrigerant

• R407C (Non-Ozone Depleting


Refrigerant) is standard for all
Genesis DX models
• Other refrigerant such as R134a or
R22 is available as options
Microprocessor Control
All Genesis units are fitted with our Genius III controller
• Built-in Auto Sequencing
• Support various communication
protocols (Modbus, BACNet,
Lonworks,etc.)
• Customizable program

3 different display options are available.

LCD Monochrome Color Touch Screen


Touch Screen
BENEFITS
 Flexibility
• Because of Full Modular Design, different combinations of modules could be
put together to accurately meet the cooling requirements.
• Option of either tandem (two compressors in one refrigeration circuit) or
separate single circuits.

 Compact / Small Footprint


• High cooling capacity in a small footprint (42kW in 1 m2) due to large coil
face area which provides higher efficiency.

 High Performance & Efficiency


• The use of the highly efficient scroll compressors together with the precise
control of the EEV & the large face area of the cooling coil makes the unit
very efficient & enable higher capacities for the unit.
 Easy Transportation
• The compact size of the basic modules as well as the fact that larger
units can be broken down into separate sets of basic modules enables
the unit to fit/pass through places where space is limited.

+
 Front Access ONLY
• Only front access is required for maintenance & service of all components.
This allows user to save space by eliminating the need to allocate
additional space at the side & rear of the unit, just to access the unit. The
hinged front panels could also be removed for better access.

unit

Max. 800mm front space is required


 Short Lead Time
• Standardized & common parts used in the entire range makes it easy to
keep stock & assemble which enables shorter lead time. 2-3 weeks
compared to 4-6 weeks.

 Future Expansion
• Future expansion of existing installation is possible due to modularity of
the design. User can add more modules to increase capacity to meet new
requirements. No need to purchase entirely new set of unit & accessories.

 Common Parts
• Use of common parts throughout the entire range makes it easy to keep &
manage spare parts.
• Reduced inventory required for service and maintenance as all models
use the same parts.
Why Gen-X?

 To address certain requirements & needs of the


market not met by the Genesis series.
Overall Features of
Gen-X
 Modular Frame
 Easily customizable to larger unit
 Smaller Foot Print
 Front Service
 Can accommodate up to 8 rows coil
 Belt driven fan (Downflow unit)
 Plug Fan (Upflow & Downflow unit)
 Electronic Expansion Valve (DX units)
 Genius III Controller
2 Basic Frame

835
835

750 500

Unit frame for Gen-X is constitution of multiple basic frames.


GEN-X Component Layout

1. Electrical Panel
2. Cooling Coil
3. Air Filter
4. Scroll Compressor
5. EEV
6. Belt driven fan
7. Electric Heaters
Scroll Compressor
• High Efficiency
• Low Noise operation
• Reliable

Heaters
• Incoloy Sheathed Element
• Stainless Steel Fins
• Balance over 3-phase
• Thermal overload protection
Cooling Coil
• V-Frame
• Multiple rows
• High performance Inner Groove
Copper Tubes (For DX)
• Large surface area
• Stainless Steel Intermediate Drip
Tray & Main Condensate Tray
• Dual Coil Option for Elegant &
Deluxe series
Centrifugal Blower Fan
(Downflow)

• DIDW Forward Curve


• Belt Driven
• Independent Motor for each fan
• Adjustable Pitch Pulley
Plug Fan (Upflow &
Downflow)
• Single Inlet Centrifugal Fan
• Backward Curve
• Direct Driven
• Higher Efficiency

EC Fan (Optional)
• Direct Driven
• Variable Speed
• High Efficiency
• Energy Saving
• Less Heat
Humidifier Electronic Expansion Valve
• Steam Electrode Boiler • Rapid and precise superheat control
• Adjustable Steam Production • Stable operation
• Disposable bottle • Better control of refrigerant flow
• Optional Servicable bottle • Energy saving
Air Filters
• EU4 or 35% ASHRAE 52/76
• Disposable
• Optional High Efficiency Filter (EU7)

Genius III Controller


• Precise control of temperature and
humidity
• Built-in Auto Sequencing
• Support various communication
standard
• Customizable program
Touch Screen Display

• Color or Monochrome
• User Friendly
• Easy Navigation
• Large display screen
• Animated Icons
• Trend Graph for temperature and humidity
GEN-X SERIES

Commander Chilled Water Unit

Deluxe Chilled Water Dual Coil Unit

Elegant Air Cooled, Water Cooled, Dual Coil (DX + CW)

Air Cooled & Water Cooled unit with higher


Performer
performance within minimal foot print.
Commander Range

• Chilled Water
• 60kW to 150kW
• For large data center
• Minimum Footprint
• Front Access
• Easy Installation and Servicing
Gen-X Commander Range
Deluxe Range

• Dual Coil Chilled Water System


• 60kW to 135kW
• For large data center
• Better Redundancy
• Front Access
• Specialized control through Genius III
Controller
Gen-X Deluxe Range
Elegant Range

• Air Cooled
• Water Cooled
• Dual Coil (DX + CW)
• 50kW to 90kW
• High Sensible Heat Ratio
• Ideal for Data Center
• Front Access
Gen-X Elegant Range
Performer Range

• Air Cooled
• Water Cooled
• 60kW to 120kW
• High Performance
• Minimal Foot Print
• For Large Data Center
• Front Access
Gen-X Performer Range
THANK YOU
Q & A
What we hope to achieve by
introducing Genesis & GenX
 To help you fully meet & comply to all the different types of
requirement of the market as close as possible.
 More new design in the future to help fill other areas of the market.