SYSTEM
DEHYDRATION
Purpose : to reduce water content
Common target : 10 lb/MMSCFD
Chemical used : Glycol
Glycol can be Mono-ethylene (MEG) or
Tri-ethylene (TEG)
Glycol can be regenerated by applying
heat up to 100degC (water vapor point)
Need process warranty from licensor
MONO ETHYLENE GLYCOL
(MEG)
(+):
(-):
TRI-ETHYLENE GLYCOL
(TEG)
(+):
(-):
Major Equipment
Glycol Contactor
Heat Exchanger
Reboiler
Filter
Flash Separator
Glycol Pump
Flow Diagram
Gas Outlet
Lean Glycol
Glycol
Rich Glycol Regenerator
Gas
Inlet
Glycol Contactor
to contact the glycol with gas that will be
dehydrated.
Equipment is vertical vessel (column)
Size based on calculation by vendor
Design Pressure is follow upstream pressure
Internal Vessel : Structure packing for glycol
contact (sulzer, etc)
Scrubber can be designed integrated but need
to assure chimney tray is not leak.
Glycol Contactor
Structure Packing
Chimney Tray
Glycol Containment
Condensate Containment
Reboiler
to regenerate glycol by heating up to 100
degC (water vapor point)
Heating can be done using gas burner or
electric burner.
Gas burner will need fuel gas supply, high
electric spark, UV detector, and Burner
Management System (BMS) Panel.
Reboiler