CAR NG Peel Off

2022. 10. 20
I. Issue NG
1. Issued Date/Issued Place : 10/17, Heesung Patrol
2. Rate NG/ Model : 21/130 (5.2%) – 55QNED80
3. Issue Detail - Attached
II. Defect Analysis & Result Testing

Defect Analysis Adhesion and Retention Testing Result


1. Product Status 3. Adhesion Testing Result
1) Production date : 8/25~8/26 1) Adhesion Result : OK
2) LOT of Material: 7/1 Spec : 1000gf/inch  Result : 1291~1437

2. Produc NG Analysis Report


1) When the product will be pasted on
the cover bottom, the tip of the prod-
uct is touched by hands too often.
 visible on the tip of the product is
curved
2) Checked at least 12 hours after past-
ing
3) Temperature/Humidity: 28 degrees
left and right

4) How to hold the tip of the tape


4. Retention Result : OK )
(Method : Load 1Kg, (4 hours: 80⁰C/0%), (24 hours: 25⁰C/
Normal 50%)

Abnormal (Excessive Spec : Maximum shift distance 0.5mm/1hr Result : “0”


pressure on the tip of
the product)

▶ Visible from the ▶ The part of the tape that gets more
shape that is sepa- pressure causes the product's adhe-
rated from the line sion to be weak, so that the product
becomes peel off.
III. Conclution Testing Result, Improvement Steps & Schedule Progress

Inspection Result Schedule of Improvement Adhesion


1. Adhesion Testing Result : Adhesion  OK
Retention  OK 1. Improvement of Adhesion ~ 10/25
1) Improvement adhesive spec
2. NG Product Analysis
 min 1200  min 1400
The tip of the tape
is pulled 2) Increase aging time
▶ Visible from the  min 48hr  Min 60hr
shape that is sepa- ▶ The part of the tape that gets more
▶ Visible
rated fromfrom the
the line pressure causes the product's adhe-
shape that is sepa- sion to be weak, so that the product
rated from the line becomes peel off. 2. Next sample test date
1) Sample arrived ~ 10/25
2) Adhesion and Retention testing ~ 10/26
3) submission of improvement samples ~ 10/27

Improvement Steps

1. Provide additional time when attaching tape, and minimize


the occurrence of differences in the method of attaching to
each individual.
2. Increased Aging time during Adhesion Testing
 Improved Adhesive Strength Test 200gf