CONCRETE AND MATERIAL 2 way slab or 1 Way Slab?
SPECIFICATION
Short span/Long span= ≥ 0.5 Two way slab
Compressive Strength (fc’) – 26.70 N/mm2
Short span/Long span= ≤ 0.5 One way slab
Yield Strength (fy) – 414.0 N/mm2
Short Span (La) - 3.00 m
Long Span (Lb) – 3.45 m Solution:
(m) - 0.87
3.00 m/ 3.45m= 0.87 ≥ 0.5 Two way
Ratio
Conc. Cover (d’) - 20 mm
Slab Bar Size (db) – 12 mmø slab
Minimun THK of Slab
Effective Depth (de) 1/180 ( Perimeter of panel)=
Short Span= t-(2xConcrete Cover)- Computed THK
(0.5xSteelBarø)
1/180 ( 2(3000)+2(3450))=
= 125-(2x20)-(0.5x12mmø)
71.67≈72mm
= 79 mm
Long Span= t-(2xConcrete Cover)-(1.5xSteelBarø)
Min. Thickness (ACI Code 9.5.3.3 and
= 125-(2x200-(1.5x12mmø 9.5.3.2) = 125mm
=67 mm Final Thickness = 125mm
Slab 1 – Case 9
Loading Computation Load Factoring = 1.2DL + 1.6LL
= 1.2(5.05)+1.6(2.28)
A. Dead Loads = 9.71 KN/m2
Wslab 2.94 KN/m2 Moment Calculation
Wwaterproofing 0.25 KN/m2
Wplasterontiles 0.25 KN/m2
Negative Moments @ Cont. Edge
Wtilesw/mortar 0.77 KN/m2 (DL+LL)
Total 4.21 KN/m2 Short Span Coeff. Ca. neg = 0.068
+ 20% for additional fixtures 0.84 KN/m2 Long Span Coeff. Cb neg = 0.025
Grand Total Dead Loads5.05 KN/m2
Ma (3m) = 0.068(9.71kn/m2)(3m^2)
(1m)
B. Live Loads 1.90 KN/m2 Ma (3m) = 5.94 KN-m
+ 20% Allowance 0.38 KN/m2
Mb (3.45m)= 0.025(9.71 KN/m)(3.45^2)
Grand Total Dead Loads 2.28 KN/m2 (1m)
Mb (3.45m)= 2.89 KN-m
Slab 1 – Case 9
Moment Calculation Positive Moments Long Span
(DL+LL)
Long Span DL Coeff. = 0.015
Positive Moments Short Span
Long Span LL Coeff. = 0.022
(DL+LL)
MaDL(3m) = 0.015(5.05kn/m2)(3.45m^2)
Short Span Coeff. Ca. neg = 0.026 (1m)
Long Span Coeff. Cb neg = 0.036 Ma(3.45m)DL = 0.90 KN-m
MaDL(3m) = 0.026(5.05kn/m2)(3m^2)(1m) Mb (3m)= 0.022(2.28 KN/m)(3.45m^2)(1m)
Ma(3m)DL = 1.18 KN-m Mb(3.45m)LL= 0.60 KN-m
Mb (3m)= 0.036(2.28 KN/m)(3m^2)(1m) Total Moment MTb= 1.50 KN-m
Mb(3m)LL= 0.74 KN-m
Total Moment MTa= 1.92 KN-m Negative Moments @ Discont. Edge
(1/3 of positive
Moment)
Ma(3m)= (1/3x1.92) = 0.64 KN/m
Mb(3.45m= (1/3x1.50) = 0.50 KN/m
Slab 1 – Case 9
Design
-Ma = 5.94 KN-m
Mta = 1.92 KN-m
de = 79 mm
de = 79 mm
fc’ = 27.60 N/mm2
fc’ = 27.60 N/mm2
fy = 414 N/mm2
fy = 414 N/mm2
b = 1000 mm
b = 1000 mm
Max Spacing= 300 mm
Max Spacing= 300 mm
ALONG SHORT DIRECTION (CONTINOUS
ALONG SHORT DIRECTION (MIDSPAN) EDGE))
Mu=0.90(Asfy(d-a/2) Mu=0.90(Asfy(d-a/2)
1.92(10^6)=0.90(As(414)(79-(As(414)/0.85(27.60) 5.94(10^6)=0.90(As(414)(79-(As(414)/0.85(27.60)
(1000)/2) (1000)/2)
As= 65.72 mm2 As= 206.58 mm2
No. of Bars = 1000 mm/ 300 mm = 3 pcsBars No. of Bars = 1000 mm/ 300 mm = 3 pcsBars

FINAL DESIGN @ MIDSPAN (L/2) = 1500 FINAL DESIGN @ MIDSPAN (L/4) = 750 mm
mm SLAB BAR SIZE = 12mmBAR @300 MM
SLAB BAR SIZE = 12mmBAR @300 MM SPACING ON CENTER
SPACING ON CENTER
Slab 1 – Case 9
Design
-ML = 2.89 KN-m
MTb = 1.50 KN-m
de = 67 mm
de = 67 mm
fc’ = 27.60 N/mm2
fc’ = 27.60 N/mm2
fy = 414 N/mm2
fy = 414 N/mm2
b = 1000 mm
b = 1000 mm
Max Spacing= 300 mm
Max Spacing= 300 mm
ALONG LONG DIRECTION (CONTINOUS EDGE))
ALONG LONG DIRECTION (MIDSPAN) Mu=0.90(Asfy(d-a/2)
Mu=0.90(Asfy(d-a/2) 2.89(10^6)=0.90(As(414)(67-(As(414)/0.85(27.60)
1.50(10^6)=0.90(As(414)(67-(As(414)/0.85(27.60) (1000)/2)
(1000)/2) As= 117.52 mm2
As= 60.51 mm2
No. of Bars = 1000 mm/ 300 mm = 3 pcsBars
No. of Bars = 1000 mm/ 300 mm = 3 pcsBars
FINAL DESIGN @ MIDSPAN (L/4) = 862.5
FINAL DESIGN @ MIDSPAN (L/2) = 1725 mm
mm SLAB BAR SIZE = 12mmBAR @300 MM
SLAB BAR SIZE = 12mmBAR @300 MM SPACING ON CENTER